DOWNLOAD LG WD-1280TDP5 Service Manual ↓ Size: 33.37 MB | Pages: 56 in PDF or view online for FREE

Model
WD-1280TDP5
Pages
56
Size
33.37 MB
Type
PDF
Document
Service Manual
Brand
Device
Washing Machine
File
wd-1280tdp5.pdf
Date

LG WD-1280TDP5 Service Manual ▷ View online

36
NO
2. Water Leak from Dispenser
Are the gasket (seal) 
and door cleaned regularly?
Is the door or gasket damaged?
Are the inlet hoses loose or cracked/split?
Replace the damaged parts.
Replace the 
Inlet Hoses
.
Clean the periphery of 
Gasket
and 
Door 
regularly.
3. Unknown – Water on Floor 
YES
Is the washer horizontal ?
Adjust the height of washing machine to be kept
horizontally. (Page 7)
NO
Are the drain filter and manual
drain hose open?
YES
NO
Check!!
Turn the filter cap clockwise to close.
YES
YES
NO
37
9-1. FILTER ASSEMBLY (LINE FILTER)
When Resistance (Ohm) checking the Component, be sure to turn the power off,
and do voltage discharge sufficiently.
Wiring
diagram
Circuit in the MAIN PWB / Wiring Diagram
Test
points 
and 
Result
Test Points
Result
WH (1) to RD (3)
WH (3) to RD (1)
0 Ω
0 Ω
WARNING
(1)
(3)
(1)
(3)
RD
WH
38
9-2. DOOR LOCK SWITCH ASSEMBLY
Wiring
diagram
Circuit in the MAIN PWB / Wiring Diagram
MAIN PWB
Vdc
Vac
MICOM
12V
12V
4
1
3
2
4
1
3
2
Relay
Relay
NA4
1
2
3
4
1
2
3
4
2
3
4
PTC
PTC
Door switch
SOLENOID
5
YL
BL
RD
BK
AC
Common
terminal
of Valve
Function
The Door Lock Switch Assembly consists of a Heating PTC, a Bimetal,
a Protection PTC, and a Solenoid. It locks the door during a wash cycle.
1. Operation for door closing
- After the system turns on, PTC heating starts up through terminal 2~4 s
authorizing the power on.
- After PTC heating starts up and before solenoid operation is driven,
force the system to the off position through CAM.
Door close
- Authorizing one impulse through terminal 3~4 (PTC & solenoid) will
make the door locked.
- Door lock is detected when switches in terminal 4~5 are set closed.
CAM rotation will forcibly clear off the connection.
The maximum, allowable number of impulse authorizations is 2.
Upon the third authorization of the impulse, the position of CAM goes
back to the door-open position.
- Authorizing the impulse occurs in 4.5 seconds upon input for max
performance and two authorization processes are allowed at most.
Normal operation period of PTC heating: 1.5 — 5 seconds.
(Defects from the development process.)
2. Operation for door opening
- With a temporary stop, door automatically opens by CAM rotations after
authorizing the impulse from the terminal 3 ~ 4 and the power turns 
off — maximum of 3 times of the authorizing period.
- Upon the fourth authorization of the impulse, the position of CAM goes
back to the door-close position.
39
Test
points
Result
Test Points
(2) to (4)
(3) to (4)
(4) to (5)
(2) to (4)
Result
700-1500 Ω
60-90 Ω
Infinity
120 Vac
Remarks
At 77
¡F 
(25
¡C
)
At 77
¡F 
(25
¡C
)
Voltage Input
(2)
(3)
(4)
(5)
Page of 56