DOWNLOAD LG WD-10384N / WD-10384T Service Manual ↓ Size: 2.04 MB | Pages: 34 in PDF or view online for FREE

Model
WD-10384N WD-10384T
Pages
34
Size
2.04 MB
Type
PDF
Document
Service Manual
Brand
Device
Washing Machine
File
wd-10384n-wd-10384t.pdf
Date

LG WD-10384N / WD-10384T Service Manual ▷ View online

20
YES
YES
YES
NO
NO
NO
NO
NO
YES
YES
YES
YES
option (HOT)
MAX
max
ABNORMAL SOUND
SOFTENER DOES NOT FLOW IN
Fix the bolt tightly.
Replace the V-belt
(4400FR3116A)
Replace the motor.
Refer to
^NO WATER SUPPLY_
Check the wiring on the 
dispenser.
Put it in the correct
compartment.
Clean the cap and
drawer.
Is the pulley bolt loosened?
Is the belt worn?
Is there friction noise from the motor?
Is water supplied?
Are receptacles correctly connected to the
terminals of inlet valve?
Is softener put in the correct compartment of
drawer?
Is the softner cap clogged?
21
AC 220-240V
NO
NO
YES
YES
YES
NO
NO
NO
NO
YES
YES
NO
PWB ASSEMBLY (MAIN)
PWB ASSEMBLY (MAIN)
1
2
Time Delay
ime Delay
Replace the sensor 
(pressure)
Replace the PWB
assembly  
Repair drain hose
Remove foreign
material.
Reconnect or repair the
connector
Replace the pump
assembly
Replace the PWB
assembly (Main) 
When pressing [Medic Care Rinse] and [Time
Delay] at the same time after draining, 
is  the water level frequency 252 or more?  
When pressing  [Medic Care Rinse]
[Time Delay]
buttons at the same time while wash, is the water
level frequency between 220 - 240V~?
Checking voltage between two pins as press
the power button is the voltage 
220 - 240V~ ?
Is the drain hose twisted or frozen?
Is the impeller of the drain pump clogged?
Is the connector disconnected,
disassembled?
Is the coil of drain pump cut-off?
(resistance of coil is 90~160
Ω)
When checking voltage between connectors
(
)on spinning, is the voltage 
220 - 240V~  as the figure?
HEATING WITHOUT WATER
DRAIN MALFUNCTIONING
22
NO
YES
YES
WASH HEATER TROUBLE
When checking the voltage between 
connector the PWB assembly (Main)during 
whites washing ,Is the voltage 
220 - 240V    ?
Replace the PWB 
assembly (Main)
YES
NO
After power off and the heater terminal is
disconnected, is the resistance 10 to 30   ?
Replace the heater 
assembly
NO
After power off,is the resistance of wire
(RED-YELLOW) connectors between
10    to 30   ?
Normal
NO
YES
RED
YELLOW
1
6
1
2
3
  ~    
AC 220-240V
PWB ASSEMBLY (MAIN)
(1)
Replace the thermistor
(6322FR2046)
Push the thermistor
tightly to the rubber.
When disconnect the connector (1) on the 
PWB assembly (Main) is the resistance of the 
Natural connectors 
~ ( Blue White),
(White)
₩between  2.5kΩ to 180kΩ
(105
~0
)?
When checking thermistor on the tub, 
is the thermistor loosened above 2mm from 
the rubber?
HEATING CONTINUOUSLY ABOVE 
THE SETTING WATER TEMPERATURE
23
NO
YES
YES
YES
NO
NO
1
4
5
2
1@
10@
1 2 3 4 5 6 7 8 9 10
5
NO
YES
3
Time Delay
ime Delay
SPIN TROUBLE
Check the sensor
(Pressure) or hose 
(Sensor). 
If the problem is on the
sensor or the hose, replace
the sensor or the hose.
Normal
Correct the connector.
Replace the motor
assembly.
(4681FR1194A) 
Check on the spinning, is the frequency of the
water level 248 or more. The frequency can be 
checked by pressing the Medic Care Rinse and
Time Delay buttons at the same time on the program.
When pressing Pre Wash and Crease Care buttons
at the same time after power off, press the  START /
PAUSE button 2 times, is the drum low speed spin?
Is it disconnected, or disassembled?
~Black : 2pin ( ), White : 2pin( ), White : 2pin( ),
Yellow : 4pin( ), White : 3pin( )
Check the motor connector, Is the resistance between
the terminal in figure the same as below?
Resistance between terminals  
: 0.5~1.0
⑩ : 1.5~2.5Ω
Be sure to unplug the machine before measuring.         
MOTOR TERMINAL
Replace the PWB assembly.
Page of 34
Display

Click on the first or last page to see other WD-10384N / WD-10384T service manuals if exist.