LG WD-10344ND Service Manual ▷ View online

20
NO
NO
NO
YES
YES
YES
YES
option (HOT)
MAX
MAX
max
YES
YES
NO
Fix the bolt tightly.
Replace the STATOR
ASSEMBLY or ROTOR
ASSEMBLY.
Is the motor bolt loosened?
Is there friction noise from the motor?
ABNORMAL SOUND
SOFTENER DOES NOT FLOW IN
Refer to
NO WATER SUPPLY
Check the wiring on the 
dispenser.
Put it in the correct
compartment.
Clean the cap and
drawer.
Is water supplied?
Are receptacles correctly connected to the
terminals of inlet valve?
Is softener put in the correct compartment of
drawer?
Is the softner cap clogged?
21
NO
YES
YES
YES
YES
NO
NO
NO
NO
YES
YES
NO
Replace the sensor 
(pressure)
Replace the PWB
assembly  
Repair drain hose
Remove foreign
material.
Reconnect or repair the
connector
Replace the pump
assembly
Replace the PWB
assembly (Main) 
When pressing [Intensive] and [Spin] at the same
Intensive] and [Spin]buttons at 
 time after draining, is  the water level frequency
252 or more?  
When pressing [
 the same time while wash, is the water level 
frequency between 230~245~?
Checking voltage between two pins as press
the power button is the voltage 
220 - 240V~ in without water condition?
Is the drain hose twisted or frozen?
Is the impeller of the drain pump clogged?
Is the connector disconnected,
disassembled?
Is the coil of drain pump cut-off?
(resistance of coil is 90~160
)
When checking voltage between connectors
(
,  ) on spinning, is the voltage 
220 - 240V~  as the figure?
HEATING WITHOUT WATER
DRAIN MALFUNCTIONING
220-240V
MAIN PWB ASSEMBLY
MAIN PWB ASSEMBLY
1 2
22
YES
WASH HEATER TROUBLE
When checking the voltage between 
connector the PWB assembly (Main)during 
Cotton 95°C washing, Is the voltage 
220 - 240V    ?
Replace the PWB 
assembly (Main)
YES
NO
After power off and the heater terminal is
disconnected, is the resistance 10 to 30   ?
Replace the heater 
assembly
NO
After power off,is the resistance of wire
(RED-YELLOW) connectors between
10    to 30   ?
Normal
NO
YES
RED
YELLOW
1
2
3
  ~    
Push the thermistor
tightly to the rubber.
When checking thermistor on the tub, 
is the thermistor loosened above 2mm from 
the rubber?
HEATING CONTINUOUSLY ABOVE 
THE SETTING WATER TEMPERATURE
NO
YES
6
3
220 - 240V~
MAIN PWB ASSEMBLY
(1)
6
3
MAIN PWB ASSEMBLY
Replace the THERMISTOR
(6322FR2046C)
When disconnect the connector (1) on the  
MAIN PWB ASSEMBLY is the resistance of the 
natural connectors 
(White),
(Blue/White)
between  2.5k
to 180k
(105
~0
)?
23
NO
YES
YES
YES
NO
NO
YES
NO
NO
YES
1
2
1
3 4
2
SPIN TROUBLE
Check the sensor
(Pressure) or hose
(Sensor). If the problem
is on the sensor or the
hose, replace the sensor
or the hose.
Normal
Correct the connector.
Correct the connector.
Replace the STATOR
ASSEMBLY
(4417FA1994E)
Check on the spinning, is the frequency of the
water level 248 or more? The frequency can be 
checked by pressing the Intensive and Spin buttons
at the same time on the program.
When pressing IntensiveRinse Hold and POWER
buttons at the same time after power off, press the
Start/Pause button 2 times, is the drum low speed
spin?
Is it disconnected, or disassembled?
[White : 3pin( ), Red:3pin( ), Red:3pin( ),
Natural:4pin( )]
Is it disconnected, or disassembled?
[White:3pin ( ), White:4pin ( )]
Check the motor connector, Is the resistance of
the terminal same as the figure?
MOTOR TERMINAL (1)
Resistance of terminal: 
About 5
10
Replace the MAIN PWB ASSEMBLY
Page of 34