DOWNLOAD LG F14953WHS Service Manual ↓ Size: 39.1 MB | Pages: 56 in PDF or view online for FREE

Model
F14953WHS
Pages
56
Size
39.1 MB
Type
PDF
Document
Service Manual
Brand
Device
Washing Machine
File
f14953whs.pdf
Date

LG F14953WHS Service Manual ▷ View online

BL
BR
YL
1
8
NA
2
3
3
R
D
5
NA
1
Y
L
6
3
1
3
5
2
B
L
1
NOISE FILTER
NA
NA
8
1
3
9
8
5
G
R
2
GR/
YL
3
5
4
8
2
Y
L
7
CON4-1
2
2
O
R
nly
B
L
1
FUSE
Power
2
1
7
4
4
2
4
RD-1
Black
1
3
POWER CORD
6
5
R
D
4
2
1
1
3
1
2
V
L
5
BL
B
L
1
GR
/
YL
RD
O
R
Yellow
3
B
L
4
B
L
4
BL
6
7
4
4
3
6
FUSE
R
D
1
Y
L
2
4
3
6
1
1
RD
3
4
WASHING
5
Heater
2
6
3
Tap Relay
R
D
HEATER
3
2
NATURE
3
BL
W
H
2
Buzzer
Display POWER
YL
G
R
BR
Main PWB&DISPLAY PWB
DATA LINKER
9
7
3
2
Y
L
5
DISPLAY 
1
2
4
B
R
B
R
70
171
321
302
Tap Relay
320
171
02
43
320
BL
BL
43
60
BL
16
Wiring Diagram 3/3
17
PCB Layout (Main)
LCD Display
LCD Display
Circulation Pump
LCD Display
LCD Display
AG SENSOR
Measure R impossible
here Just Check cut-off
LCD Display
LCD Display
Hall Sensor Control
LCD Display
LCD Display
Thermistor
LCD Display
LCD Display
Motor Stator Control
V ~ U / U ~ W
/ W ~ V
R : 8 ~11
W
U
V
LCD Display
LCD Display
PCB POWER
LCD Display
LCD Display
AG
LCD Display
LCD Display
LCD Display
LCD Display
LCD Display
Heater
LCD Display
LCD Display
Display Power
Pressure Switch
&
Aqua stop
&
Measure Hz impossible
Here. Just Check cut-off
Common
Main Valve
3.5~4.5k
Pre Valve
3.5~4.5k
AG Valve
3.5~4.5k
Short
Common
Common
Common
Hb
(5~15K
Ω)
Aqua
stop
Long
LCD Display
LCD Display
Inlet Valve Control
Door S/W
&
DrainPump
Thermistor for wash
Ciculation
Pump
(152~176
Ω)
Door
S/W
Drain
Pump
(152~176
Ω)
Thermistor for AG
18
Before servicing ask the customer what the trouble is.
Check the adjustments. (Power supply :220-240V~, Removal of transit bolts etc..)
Check the troubles referring to the troubleshooting.
Decide service steps referring to disassembly instructions.
Then, service and repair.
After servicing, operate the appliance to see whether it works OK or NOT.
7. TROUBLESHOOTING
7-1. BEFORE SVC CHECKING
7-2. LOAD TEST MODE
1 Press and Hold ‘
Option (Left)
’ & ‘
Rinse
’ buttons
and then press ‘
Power
’ button.
2 The washer must be empty and the controls must be in the off state.
3 Press Power with above two buttons pressed and then buzzer will sound.
4 Press the Start/Pause button repeatedly to cycle through the test modes
1
2
3
4
5
6
None
1 time 
2 times 
3 times 
4 times 
5 times 
6 times 
7 times 
8 times 
9 times 
10 times 
11 times 
12 times 
13 times 
14 times 
Turns on all lamps and locks the door.
Tumble clockwise.
Low speed Spin.
High speed Spin.
Inlet valve for prewash turns on.
Inlet valve for main wash turns on.
Inlet valve for hot water turns on.
Inlet valve for steam turns on.
Inlet valve for bleach turns on.
Heater turns on for 3 sec.
Circulation pump turns on.
Drain pump turns on.
Water level Sensor for Steam
Steam Heater turns on for 1.2 sec.
Off
rpm (42~50)
rpm (55~65)
rpm (125~155)
Water level frequency (25~65)
Water level frequency (25~65)
Water level frequency (25~65)
Water level frequency (25~65)
Water level frequency (25~65)
Water temperature
Water level frequency (25~65)
Water level frequency (25~65)
Water level frequency of TSG (0~255)
TSG temperature
-
Number of times the
Start/Pause button is pressed
Check Point
Display Status
19
7-3. HOW TO CHECK THE WATER LEVEL FREQUENCY 
7-4. HOW TO KNOW TO TEMPERATURE OF EACH THERMISTOR
AT OPERATING CONDITION.
Press the 
Favorite
and
Option (Left)
button simultaneously.
Press the
Option (Left)
and
Temp.
button simultaneously.
The digits means water level frequency. (10
-1
kHz)
ex) 241 : Water level frequency = 241 x 10
-1
kHz
24.1 kHz
Thermistor in tub temperature.
Page of 56