LG F1480RDS25 / F1480RDS29 Service Manual ▷ View online
29
NO
Are the resistance of the
Hall Sensor
5~15kΩ?
Motor Locked Error (LE)
[Pre Check]
• Gentle wash cycles, such as Perm Press, Delicates, Hand Wash, and Wool/Silk should only be used for smaller loads.
• Gentle wash cycles, such as Perm Press, Delicates, Hand Wash, and Wool/Silk should only be used for smaller loads.
Because these cycles are more gentle in tumbling and spinning, putting too much in the drum can register an issue
with the motor. Remove items, reset unit and test with a Rinse/Spin cycle.
with the motor. Remove items, reset unit and test with a Rinse/Spin cycle.
• Don’t replace the PCB, when the hall sensor is replaced.
Replace the PCB, when the LE is displayed after replacing the hall sensor.
Is the
Connector
connected correctly to
the
Main PCB
and the
Motor
?
Is the
Harness
alright ?
YES
NO
YES
YES
YES
YES
NO
Disassemble the
Rotor
.
Is the
Magnet
of rotor cracked or broken?
• Ha ~ Common
: 5 ~ 15 kΩ
• Hb ~ Common
: 5 ~ 15 kΩ
Replace the
Main PCB
.
Press the
Power
button &
Start / Pause
button.
Does the
Drum
stop when the start/pause button is pressed to start the cycle ?
Or Sometimes does the
Drum
rotate weakly (under 15rpm)?
Magnet
Ha
Hb
Common
Is the resistance the same
between
between
Stator
points?
V~U / U~W / W~V : 8~11Ω
V U W
V U W
Reconnect or repair the
Connector
.
Or replace the
Harness
.
Replace the
Rotor
.
Replace the
Hall Sensor
.
Disassemble
hall sensor carefully.
(Next page)
NO
Replace the
Stator
.
30
Disassemble the Hall Sensor
1) Disassemble the hook of Hall Sensor by (-) driver.
2) Pull up Hall Sensor slowly as shown in picture.
1) Adjust the hole of Hall Sensor to
the hooks of stator as shown in red circle
2) Push down the Hall sensor,
and assemble to the hook securely.
Caution
If you disassemble by force,not following the directions,
the hooks of stator(red circled) might break.
Hence need change of stator assembly.
the hooks of stator(red circled) might break.
Hence need change of stator assembly.
So disassemble cautiously.
1
Assemble the Hall Sensor
2
[Note]
Hall Sensor Part No.
• 24” / 25” : 6501KW2001A
• 24” / 25” : 6501KW2001A
• 27” : 6501KW2002A
31
Check if there is some water on the base ?
Which part have broken.(ex.
Tub, dispenser, inlet hose,
circulation hose, steam
generator, pump, drain hose)
Replace the broken part.
YES
Check if there is some water on the base ?
YES
Assemble the aqua switch.
Reconnect or repair the
connector. Or replace the harnes.
NO
NO
NO
Replace the Aqua switch.
NO
Water leakage (AE)
Is the connector connected correctly to the main PCB
and the aqua switch?
Or is the harness alright?
and the aqua switch?
Or is the harness alright?
Is Aqua switch assembled correctly to
the base?
When you press and hold the styrofoam
in the Aqua switch, is AE displayed?
YES
YES
32
Dry Heater Error (dHE)
Is the
Connector
connected correctly to
the
Main PCB
and the
Dry Heater or Fan Motor
?
Or is the
Harness alright?
Reconnect or repair the
Connector
.
Or replace the
Harness
.
Clean the
Bellows
.
Replace the
Thermistor
.
Is the resistance of t.he
Thermistor
out of range
2.5 ~ 180KΩ at 105 ~ 0°C?
YES
Disassemble the
Cabinet cover
and
Condensing Bellows.
Is there any foreign object in
Condensing Bellows
?
Disassemble the
Dry Fan Assy and Dry Duct Upper,
and clean foreign object in
Duct and Fan
.
Check for
Dry Heater
trouble.
Page 24
Check for
Dry Fan Motor
trouble.
Page 25
YES
NO
NO
NO
YES