29
Disassemble the Hall Sensor
1) Disassemble the hook of Hall Sensor by (-) driver.
2) Pull up  Hall Sensor slowly as shown in picture. 
1) Adjust the hole of Hall Sensor to 
the hooks of stator  as shown in red circle 
2) Push down the Hall sensor, 
and assemble to the hook securely.
Caution
If you disassemble by force,not following the directions, 
the hooks of stator(red circled) might  break.
Hence need change of stator assembly. 
So disassemble cautiously.
1
Assemble the Hall Sensor
2
[Note]
Hall Sensor Part No.
• 24” / 25” : 6501KW2001A
• 27” : 6501KW2002A 
30
Dry Heater Error (dHE)
Is the 
Connector
connected correctly to 
the 
Main PCB
and the 
Dry Heater or Fan Motor
?
Or is the 
Harness alright?
Reconnect or repair the 
Connector
.
Or replace the 
Harness
.
Clean the 
Bellows
.
Replace the 
Thermistor
.
Is the resistance of t.he 
Thermistor
out of range 
2.5 ~ 180KΩ at 105 ~ 0°C?
YES
Disassemble the 
Cabinet cover 
and 
Condensing Bellows.
Is there any foreign object in 
Condensing Bellows
?
Disassemble the 
Dry Fan Assy and Dry Duct Upper,
and clean foreign object in 
Duct and Fan
.
Check for 
Dry Heater
trouble.                        
Page 24
Check for 
Dry Fan Motor
trouble.                   
Page 25
YES
NO
NO
NO
YES
31
Dry Heater Trouble
After power off, is the resistance of 
Dry Heater
out of
range 33 ~ 37Ω?
Is 
Thermostat
closed ?
When checking voltage between 
connectors(1,2)
on drying, is the voltage AC 220V as the figure ?

 
YES
YES
Replace the 
Dry Heater
.
NO
Replace the 
Thermostat
.
NO
Replace the 
PWB assembly (main)
.
NO
32
Dry Fan Motor Trouble
Is the 
Connector
connected correctly to
the 
Main PCB
and the 
Dry Heater
or 
Fan Motor
?
Or is the 
Harness
alright? 
Are the resistance same between 
terminal
points?
V~U / U~W / W~V : 2~5Ω
When checking voltage between 
connectors(1,2)
on drying, is the voltage DC 20~30V as the figure ?
 
YES
YES
Reconnect or repair the 
Connector
.
Or replace the 
Harness
.
NO
Replace the 
Dry Fan Motor
.
NO
Replace the 
PWB assembly
(main)
.
NO
V U W
Page of 58