DOWNLOAD LG F1407TDS6 / F1407TDSP6 / F1407TDSP7 / F1407TDSP9 / F1407TDSPU Service Manual ↓ Size: 4.35 MB | Pages: 36 in PDF or view online for FREE

Model
F1407TDS6 F1407TDSP6 F1407TDSP7 F1407TDSP9 F1407TDSPU
Pages
36
Size
4.35 MB
Type
PDF
Document
Service Manual
Brand
Device
Washing Machine
File
f1407tds6-f1407tdsp6-f1407tdsp7-f1407tdsp9-f1407td.pdf
Date

LG F1407TDS6 / F1407TDSP6 / F1407TDSP7 / F1407TDSP9 / F1407TDSPU Service Manual ▷ View online

5
2-2. DETERMINE WASHING TIME BY FUZZY LOGIC
To get the best washing performance optimal time is determined by sensing of water temperature,
selected washing temperature and laundry amount.
2-3. WATER LEVEL CONTROL
This model adopts a pressure sensor which can sense the water level in the tub.
Water supply is stopped when the water level to the preset level, then washing program proceeds.
Spinning does not proceed until the water in the tub reduces to a certain level.
water
temperature
washing time
rinsing time
the best
washing
performance
spin rhythm, time
laundry
amount
FUZZY
LOGIC
selected
washing
temperature
SENSING
EFFECT
PROCESSING
DETERMINATION
2-4. THE DOOR CAN NOT BE OPENED
While program is operating.
While Door Lock light turns on.
6
3. PARTS IDENTIFICATION
Drawer
Drum
Drain Hose
Adjustable Feet 
Shipping Blots
Power Plug 
Control Panel
Door
Lower Cover Cap
Drain Pump Filter
Drain Plug
If the supply cord is
damaged, it must be
replaced by the
manufacturer or its
authorized service
technician in order to
avoid a hazard.
ACCESSORIES 
Inlet hose(1EA)     
Option : Hot/Cold(2EA)
Spanner
7
4. INSTALLATION 
1
2
3
4
5
6
Before servicing ask the customer what the trouble is.
Check the adjustment(power supply is 220-240V~, remove the transit bolts....)
Check the troubles referring to the trouble shooting.
Decide service steps referring to disassembly instructions.
And then, service and repair.
After servicing, operate the appliance to see whether it works O·K or NOT.
STANDARD INSTALLATION
The appliance should be installed as follows.
Remove the transit bolts
(4EA:     ) with supplied
spanner. 
Keep the transit bolts and
spanner for future use.
Insert the provided 4 caps
into the hole.
1
The appliance goes up by
rotating the feet clockwise.
The appliance come down
by rotating the feet counter
clockwise.
Turn the leveling feet to set
the appliance horizontally.
Lower
Higher
REMOVE THE TRANSIT
BOLTS
INSTALL THE APPLIANCE 
ON FLAT AND FIRM SURFACE
ADJUST THE
HORIZONTAL
8
Check that the rubber packing is inside of the
valve connector.
Connect the inlet hose firmly to prevent leak.
HOW TO CONNECT INLET HOSE
CONNECT DRAIN HOSE
· Make sure that the hose is not twisted.
CONNECT POWER PLUG
The drain hose should be placed under 100cm from the floor.
· Avoid submerging the end of the hose.
· Connect the power plug to the wall outlet.
· Avoid connecting several electric devices,
It may be the cause of a fire.
Page of 36
Display

Click on the first or last page to see other F1407TDS6 / F1407TDSP6 / F1407TDSP7 / F1407TDSP9 / F1407TDSPU service manuals if exist.