LG F1407TDP9 Service Manual ▷ View online
25
9. DIS AS S E MB LY INS T R UC T IONS
Disassemble and repair the parts after pulling out power cord from the outlet.
C ONT R OL PA NE L
1
Unscrew the screws on the top plate.
2
T he plate assembly(T op) is pulled back and
then upward to arrow direction.
then upward to arrow direction.
3
T he cover(Inner) is disassembled.
1
P ull out the drawer and unscrew 2 screws.
2
Lift the side the C ontrol P anel Assembly and
pull it out.
pull it out.
1
T hree screws is unscrewed.
2
P ush out P ANE L AS S E MB LY , C ONT R OL
after P ush the hook( , ) below.
after P ush the hook( , ) below.
1
2
1
T he P WB assembly is disconnected.
2
When 7 screws are unscrewed on the P WB
insulator and the P WB assembly is
disassembled from the P WB insulator.
insulator and the P WB assembly is
disassembled from the P WB insulator.
1
3
2
P LAT E AS S E MB LY (T OP )
DR AWE R P ANE L AS S E MB LY
P ANE L AS S E MB LY , C ONT R OL
P WB AS S E MB LY
26
DIS P E NS E R A S S E MB LY
1
T he plate assembly(T op) are disassembled.
2
P ull the drawer to arrow direction.
1
T he hose clamps and the hose are
disassembled.
disassembled.
2
T he ventilation bellows are disassembled on
the tub.
the tub.
3
T wo screws are unscrewed.
DR AWE R
DIS P E NS E R AS S E MB LY
27
INL E T VA LV E
DOOR
R emoving method of remained water
1
Open the door completely.
2
R emove the two screws from the hinge.
When removing the Door Assembly, it is
necessary to hold the B racket that is inner
of the C abinet C over.
necessary to hold the B racket that is inner
of the C abinet C over.
F irst, prepare a bucket to put in the
remained water.
remained water.
P ull it out from hose.
C AP (R E MAINING HOS E )
Disconnect the wiring receptacle.
Unscrew 2 screws from the back.
Unscrew 2 screws from the back.
When reconnecting the connector
VALV E #1 (MAIN)
White / B lack - B lack
VALV E #2 (P R E )
G ray / White - B lack
28
CABINET COVER
1
The plate assembly(Top) is disassembled.
2
Pull out the drawer and unscrew 2 screws.
3
Lift the side the Control Panel Assembly and
pull it out.
1
Three screws is unscrewed.
2
Push out PANEL ASSEMBLY, CONTROL after
Push the hook( , ) below.
1
2
1
Unscrew the 2 screws from upper of the
cabinet cover.
1
Put a flat ( - ) screwdriver or putty knife into the
both sides of the pump case, and pull it out.
1
Unscrew the screw from the lower side of the
cabinet cover.
2
Unscrew the screw from the pump case.
1
3
2
PANEL ASSEMBLY, CONTROL
PUMP CASE
Click on the first or last page to see other F1407TDP9 service manuals if exist.