36
NO
2. Water Leak from Dispenser
Are the gasket (seal) 
and door cleaned regularly?
Is the door or gasket damaged?
Are the inlet hoses loose or cracked/split?
Replace the damaged parts.
Replace the 
Inlet Hoses
.
Clean the periphery of 
Gasket
and 
Door 
regularly.
3. Unknown – Water on Floor 
YES
Is the washer horizontal ?
Adjust the height of washing machine to be kept
horizontally. (Page 7)
NO
Are the drain filter and manual
drain hose open?
YES
NO
Check!!
Turn the filter cap clockwise to close.
YES
YES
NO
37
      
    !"  # $#% & '( # '(  $#)( #**%
+ +# ,#-" +(" '**-.
         
 #
'-
/  # 0 1
/ 1 # 0 
2 9
2 9
1
1
0
/
9. Part inspection
38
9-2. DOOR LOCK SWITCH ASSEMBLY
         
  
 
 
 
 
!! "#
$%&
'
(%
%
)
AC
Common
terminal
of Valve
* !
The Door Lock Switch Assembly consists of a Heating PTC, a Bimetal,
a Protection PTC, and a Solenoid. It locks the door during a wash cycle.
1.Operation for door closing
- After the system turns on, PTC heating starts up through terminal 2~4Õs
authorizing the power on.
- After PTC heating starts up and before solenoid operation is driven,
force the system to the off position through CAM.
Door close
- Authorizing one impulse through terminal 3~4 (PTC & solenoid) will
make the door lock.
- Door lock is detected when switches in terminal 4~5 are set closed.
CAM rotation will forcibly clear off the connection.
The maximum, allowable number of impulse authorizations is 2.
Upon the third authorization of the impulse, the position of CAM goes
back to the door-open position.
- Authorizing the impulse occurs in 4.5 seconds upon input for max
performance and two authorization processes are allowed at most.
Normal operation period of PTC heating: 1.5 Ð 5 seconds.
(Defects from the development process.)
2.Operation for door opening
- With a temporary stop, door automatically opens by CAM rotations after
authorizing the impulse from the terminal 3 ~ 4 and the power turns
off Ð maximum of 3 times of the authorizing period.
- Upon the fourth authorization of the impulse, the position of CAM goes
back to the door-close position.
39
Test
points
Result
Test Points
(2) to (4)
(3) to (4)
(4) to (5)
(2) to (4)
Result
700-1500 9
60-90 9
Infinity
120 Vac
Remarks
At 77
¡F
(25
¡C
)
At 77
¡F
(25
¡C
)
Voltage Input
(2)
(3)
(4)
(5)
Page of 57