DOWNLOAD LG F12A8FDA Service Manual ↓ Size: 26.82 MB | Pages: 57 in PDF or view online for FREE

Model
F12A8FDA
Pages
57
Size
26.82 MB
Type
PDF
Document
Service Manual
Brand
Device
Washing Machine
File
f12a8fda.pdf
Date

LG F12A8FDA Service Manual ▷ View online

16
n
0
Wiring Diagram 3/3
17
PCB Layout (Main)
  
 
Display
18
Before servicing ask the customer what the trouble is.
Check the adjustments. (Power supply :220-240V~, Removal of transit bolts etc..)
Check the troubles referring to the troubleshooting.
Decide service steps referring to disassembly instructions.
Then, service and repair.
After servicing, operate the appliance to see whether it works OK or NOT.
7. TROUBLESHOOTING
7-1. CHECK BEFORE SERVICE
7-2. LOAD TEST MODE
1 Touch and Hold ‘
Medic Rinse
’ & ‘
Rinse
’ buttons
and then press ‘
Power
’ button.
2 The washer must be empty and the controls must be in the off state.
3 Press Power with above two buttons pressed and then buzzer will sound.
4 Press the Start/Pause button repeatedly to cycle through the test modes
F1495BDS(1~9), F1495BD(1~9)
1
2
3
4
5
6
Display Status
Remark
Check Point
Number
0
4
10 
11
12 
13
14  
Turns on all light and locks the door.
Tumble clockwise
Low speed spin
High speed spin
Inlet valve for prewash turns on.
Inlet valve for main wash turns on.
Inlet valve for hot water turns on.
Inlet valve for steam turns on.
Tumble counterclockwise
Heater turns on for 3 sec.
Circulation pump turns on.
Drain pump turns on.
Sensor for steam
Steam heater turns on for 1.2 sec.
Off
PGM Version Information
rpm(42~50)
rpm (60)
rpm (130~140)
Water level frequency
Water level frequency
Water level frequency
Water level frequency
rpm
Water temperature
Water level frequency 
Water level frequency 
Water level frequency
AG Temperature
-
For Hot&Cold Model
For Steam Model
For Steam Model
For Steam Model
19
7-3. HOW TO CHECK THE WATER LEVEL FREQUENCY 
7-4. HOW TO CHECK THE TEMPERATURE OF EACH THERMISTOR
AT OPERATING CONDITION.
040
045
000
100
021
041
045
097
000
045
112
000
248
084
000
026
145
000
The digits indicate the water level frequency.
For example, if 255 is displayed 
the water level frequency is 25.5kHz (255 X 0.1).
Data View Type : In case of ‘040’
Touch the 
Temp.
and 
Pre Wash
button simultaneously.
If the knob is turned, the data view type is changed from 40 to 49
Touch the 
Temp.
and 
Pre Wash
button simultaneously.
If the knob is turned, the data view type is changed from 40 to 49
040
045
000
100
021
041
045
097
000
045
112
000
248
036
000
026
145
000
Thermistor in tub temperature
Data View Type : In case of ‘040’
Page of 57
Display

Click on the first or last page to see other F12A8FDA service manuals if exist.