46
9. DISASSEMBLY INSTRUCTIONS
Disassemble and repair the parts after pulling out power cord from the outlet.
1 Unscrew the screws on the top plate.
3 The cover(Inner) is disassembled.
2 The plate assembly(Top) is pulled back and
then upward to arrow direction. 
1 Pull out the drawer and unscrew 2 screws.
2 Lift the side the Control Panel Assembly and
pull it out 
1 Two screws is unscrewed.
2 Push out PANEL ASSEMBLY, CONTROL after
Push the hook below.
1 The PWB assembly(Display) is disconnected.
2 When 7 screws are unscrewed on the PWB
insulator and the PWB assembly(Display) is
disassembled from the PWB insulator.
CONTROL PANEL
Screws
Screws
Screws
Disassembly two connector
47
1 Disassembly lower cover assembly.
2 Disammembly MAIN PWB ASSEMBLY.
3 Disconnect the wiring connector.
4 The cover of PWB assembly(main) is First.
Press hook and turn the safety switch removed.
5 Disconnect connector from the wiring.
PWB ASSEMBLY(MAIN)
1 The plate assembly(Top) are disassembled.
3 Two screws are unscrewed.
3 Two screws are unscrewed.
2 Pull the drawer to arrow direction.
4 Clamp
4 Clamp
5 Cutting cable ties and the ventillation hose
are disassembly on the dispenser
5 Cutting cable ties and the ventillation hose
are disassembly on the dispenser
DISPENSER ASSEMBLY
2 Pull the drawer to arrow direction.
2
1
48
VALVE     (STEAM) 
VALVE     (PRE-WASH)
VALVE     (NORMAL-WASH)
1 Disconnect the wiring connector.
1
1
2
3
2 Remove the valve by two screws of the valve
holder.
• Rating : 220/240V 50/60Hz
• Resistant : 3.5~4.5kΩ
2
When reconnecting the connector
1 Open the door completely.
2 Remove the three screws from the hinge.
When removing the Door Assembly, it is
necessary to hold the Bracket that is inner of
the Cabinet Cover.
First, prepare a bucket to put in the remained
water.
Pull it out from hose.
VIOLET/BLACK-BLACK
WHITE/BLACK-BLACK
GRAY/BLACK
INLET VALVE
3
DOOR
Removing method of remained water
CAP(REMAING HOSE)
49
2 Push out PANEL ASSEMBLY, CONTROL after
Push the hook(     ,     ) below.
2
1
1 The plate assembly(Top) is disassembled.
2 Pull out the drawer and unscrew 2 screws.
1 Two screws is unscrewed.
3 Unscrew the screws from the lower cover.
2 Disassembly lower cover assembly.
3 Unscrew the screw from the CABINET COVER.
1
2
3 Lift the side the Control Panel Assembly and
pull it out
CABINET COVER
Two screws are unscrewed
Pull the drawer to arrow direction.
Screws
Disassembly two connector
Page of 55