LG F1096ND / F1096NDA / F1096NDA3 / F1096NDW3 Service Manual ▷ View online
40
PUMP
1
Remove pump outlet hose.
2
Remove tub pump bellows.
3
Remove cap (Remaining Hose.)
4
Disconnect the wiring.
5
Unscrew 2 screws.
6
Remove the pump.
HEATER
1
Loosen the M6 heater nut to pull out the
heater.
CAUTION
When mounting the heater, be sure to insert
the heater into the heater clip on the bottom
of the tub.
the heater into the heater clip on the bottom
of the tub.
Tub Pump
Bellows
Pump Outlet Hose
• Rating : 220~240V 2000W
• Resistant : 24.7~28.0Ω
• Rating : 220~240V 50HZ 30W
• Resistant : 160~177Ω
M6 heater nut
4
1
SWITCH ASSEMBLY, DOOR LOCK
1
Take apart the cabinet cover clamp and
release the gasket.
2
Unscrew 2 screws holding the door lock.
3
Disconnect the door lock from the wiring
connector.
WHEN FOREIGN MATERIAL IS STUCK BETWEEN DRUM AND TUB
1
Remove the heater.
2
Remove the foreign material (wire, coin and
others) by inserting a long bar through the
hole.
• Just check cut-off.
• Check the operating time.
* Door Locking time :
1~8
sec.
Check the time between from
input the power to parts
move up, then Door locked.
input the power to parts
move up, then Door locked.
* Door Releasing time :
25~100
sec.
Check the time between from off
the power to parts
move down, then Door released.
the power to parts
move down, then Door released.
1
1
1
C OLD (B LUE )
A150
A151
A153
A152
A140
A154
A110
A101
A100
A141
A131
A102
A103
A104
A430
A130
A134
A133
A276
A220
A310
A300
A440
A485
A410
A150
A151
A153
A152
A140
A154
A110
A101
A100
A141
A131
A102
A103
A104
A430
A130
A134
A133
A220
A310
A300
A440
A485
A410
A303
F300
F462
F321
F160
F432
F430
F441
F220
F120
F215
F110
F210
F225
Click on the first or last page to see other F1096ND / F1096NDA / F1096NDA3 / F1096NDW3 service manuals if exist.