LG F1091QDTA Service Manual ▷ View online
5. OPERATION
Wash program selector
9 programs can be set
depending on the type of
the laundry.
If the power button is
pressed, all lamps are on
By turning the dial, [Cotton -
the laundry.
If the power button is
pressed, all lamps are on
By turning the dial, [Cotton -
Hand Wash/Wool -Blanket-
Quick 30 -
Rinse+Spin -Baby
Care -
Delicate -
Synthetic -
Cotton Quick -Boiling Care ]
can be selected.
This is a bi-directional
This is a bi-directional
selector.
Start/Pause button
Use the button to start or pause wash
cycle.
The power turns off automatically 4
minutes after the pause button is
pressed.
cycle.
The power turns off automatically 4
minutes after the pause button is
pressed.
Child -Lock
Child Lock system can
be set and canceled by
pressing and holding
both
Medic Rinse
button
and
Pre Wash
button
simultaneously more
than 3 seconds.
Tub Clean
Tub Clean course can be set by
pressing and holding
pressing and holding
Intensive
and
Crease Care
button simultaneously.
Tub Clean is special cycle to clean the
inside of the washer.
inside of the washer.
Option
Medic Rinse : Function that offers more purity in rinse operation by
maintaining the optimum temperature for elimination of
remnant detergent. It can be selected in all courses with the
exception of Quick 30. Hand Wash/Wool, Delicate course.
Intensive :
If the laundry is heavily soiled “Intensive” option is effect
ive.
By selecting the Intensive option, the wash time may be
extended, depending on the program selected.
Pre Wash : If the laundry is heavily soiled, “Pre Wash” course is effective.
Pre Wash is available in Cotton and Synthetic Program.
Crease Care : If you want to prevent crease, select this button with spin
5-1. F1091Q/T D(T/P)2(A)(0~9)
12
Option
Child -Lock
Wash program selector
Start/Pause button
Tub Clean
Time Delay & Beep ON/OFF
How to set "Time Delay"
-Press the power button -Turn the Program
dial to select the program you require
-Press Time Delay button and set the
desired time. Each pressing of the button
advances on time delay by 3h 6h,9h and
cancel .
Time Delay is "expected time" from the
present to completion of Washing cycle or
selected process( Washing, Rinse, Spin).
The Beep on/off function can be set by
pressing and holding the Time Delay button
(About 3 seconds ).
The Beep on/off function can be set at any
time and it is automatically cancelled in the
event of a power cut.
The Beep on/off function also works when
power is off.
.
Power button
Press the button to turn power on and off.
Press the button to cancel the time delay.
Press the button to cancel the time delay.
LOAD TEST MODE
Page 17
- Press and Hold ‘
Temp.
’ & ‘
Spin
’ buttons and then press ‘
Power
’ button.
Water level frequency
- Press and Hold ‘
Temp.
’ & ‘
Medic Rinse
’ buttons simultaneously.
13
Spin Button
By pressing the Spin Button the spin speed
can be chosen
F8091Q/T D(T/P)2(A)(0~9)
Rinse Hold/No spin/400/600/800
F1091Q/T D(T/P)2(A)(0~9)
Rinse Hold/No spin/400/800/1000
F1291Q/T D(T/P)2(A)(0~9)
Rinse Hold/No spin/400/800/1200
F1491Q/T D(T/P)2(A)(0~9)
Rinse Hold/No spin/400/800/1400
Water temperature selector
Press the button to select water temperature.
95°C is selected for Cotton and Baby Care Only.
14
6. WIRING DIAGRAM / PCB LAYOUT / PROGRAMCHART
[Note]
RD : Red
RD : Red
YL : Yellow
BL : Blue
WH : White
GY : Gray
BK : Black
VL : Violet
OR : Orange
SBL : Sky Blue
NA : Natural
Display
Display
PCB Power & Heater
Pressure Switch
&
Heater Thermistor
Measure Hz impossible here
Just check cut-off.
Heater Thermistor
(44~53K , 25°C)
Pressure Switch
Common
Drain Pump
&
Door
&
Inlet alve
Door Switch
Measure R impossible here
Common
Motor
&
Hall Sensor
V ~ U / U ~ W / W ~ V
R : 8 ~11
V
U
W
Hb
(5~15k )
Ha
(5~15k )
Common
Drain Pump
(160~177 )
Pre. Valve
(3.5~4.5k )
Main Valve
(3.5~4.5k )
Heater
(24.7~28.0 )
PCB Power
PCB Layout
15
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Click on the first or last page to see other F1091QDTA service manuals if exist.