LG F1069FD6S Service Manual ▷ View online
16
DISPLAY LED
CYCLE BUTTON
STATUS LED
The display shows the vend price and remaining time
and programming options. Error codes are also
displayed here.
and programming options. Error codes are also
displayed here.
START BUTTON
OPTIONAL FUNCTION BUTTON
DISPLAY LED
1
RINSE+SPIN
Rinse,drain and spin only
Use this cycle to rinse detergent form load
Rinse,drain and spin only
Use this cycle to rinse detergent form load
LED flashes whenever the washing
cycle is in operation.
cycle is in operation.
LED flashes whenever the Rinsing
cycle is in operation.
cycle is in operation.
LED flashes whenever the Spining
cycle is in operation.
cycle is in operation.
LED flashes whenever the door lock
is activated.
is activated.
OPTIONAL FUNCTION BUTTON
3
The START LED flashes when the full vend price
has been satisfied and the cycle has been chosen.
has been satisfied and the cycle has been chosen.
START BUTTON
4
STATUS LED
5
Press the CYCLE button to select the desired cycle
based on laundry types and conditions.
based on laundry types and conditions.
Use it for the more medical wash than 75°C HOT
such as white clothes, baby clothes, sheets and
underwear.
such as white clothes, baby clothes, sheets and
underwear.
CYCLE BUTTON
90°C MEDICAL
Use it for heavy soiled fabrics such as white
clothes, baby clothes, sheet and underwear.
clothes, baby clothes, sheet and underwear.
75°C HOT
Use it for heavy soiled fabrics such as baby wear,
underwear and white clothes.
underwear and white clothes.
60°C NORMAL
Use it for normal soiled fabrics such as cotton,
linen, towels, shirts and jeans.
linen, towels, shirts and jeans.
40°C NORMAL
2
Select cycles designed for different types of fabric and soil levels
CYCLE
90°C
75°C
60°C
MEDICAL Extra Hot/Cold
HOT Extra Hot/Cold
NORMAL Hot/Cold
High
High
High
O
O
O
40°C
NORMAL Warm/ Cold
Middle
O
DELICATES
Cold/Cold
Low
O
RINSE+SPIN
(OPTION)
Cold/Cold
High
O
Wash/Rinse
Temp.
Spin
Speed
Add Super
Wash
17
18
7. WIRING DIAGRAM/PROGRAM CHART
Card Type : F1064FD6S F1064FD7S Coin Type : F1064FDS F1064FD4S OPL Tpye : F1069FD2S F1069FD3S
Program Chart
8. TROUBLESHOOTING
19
8-1. BEFORE PERFORMING SERVICE
8-2. QC TEST MODE.
Be careful of electric shock when disconnecting parts while troubleshooting.
OPL/Coin/Card Type
The washer must be empty.
1. Push the 90°C MEDICAL & 60°C NORMAL button at the same time.
2. Push the 75°C HOT button 1 times.
3. Push the START button.
3. Display will show “ ”.
8-3. HOW TO CHECK THE WATER LEVEL FREQUENCY
8-4. HOW TO CHECK THE RPM
Press and hold the ADD SUPER WASH and PERMANENT PRESS buttons simultaneously.
Press the ADD SUPER WASH AND WHITES button simultaneously.
When you check the water level, the first digit is a 0 which means 2.
A display indicating 041 is a water level frequency of 241 multiplied by 0,1 KHz , for an
actual frequency of 24,1 KHz.
A display indicating 041 is a water level frequency of 241 multiplied by 0,1 KHz , for an
actual frequency of 24,1 KHz.
Under 200 rpm: The display indicates the rpm. (Under 200 rpm)
Over 200 rpm: The display indicates the rpm. (x 10 rpm)
So, for example a display indicating 050 : rpm of 050 x 10 rpm = 500rpm
Over 200 rpm: The display indicates the rpm. (x 10 rpm)
So, for example a display indicating 050 : rpm of 050 x 10 rpm = 500rpm
Card type
1. Insert service card.
1. Insert service card.
2. Display will show “ ”
The voltage of each terminal is 220V- when the unit is plugged in.
Coin type
1. Dissemble upper coin box key.
2 Take out the coin drop from the coin box.
3. Turn on/off the toggle switch at the back of the coin box.
4. Display will show “ ”.
1. Dissemble upper coin box key.
2 Take out the coin drop from the coin box.
3. Turn on/off the toggle switch at the back of the coin box.
4. Display will show “ ”.
Number of times the
START button is pressed
Check Point
Display
None
1 time
1 time
2 times
3 times
4 times
5 times
6 times
7 times
8 times
9 times
3 times
4 times
5 times
6 times
7 times
8 times
9 times
10 times
Turns on all lamps and locks the door
rpm (42~50)
rpm(1000~1150)
Water level frequency (26,2~23,0 kHz)
Water level frequency (26,2~23,0 kHz)
Water level frequency (26,2~23,0 kHz)
Water level frequency (26,2~23,0 kHz)
rpm (42~50)
Water level frequency (26,2~23,0 kHz)
Water level frequency (26,2~23,0 kHz)
Water level frequency (26,2~23,0 kHz)
Water level frequency (26,2~23,0 kHz)
rpm (42~50)
Tumble Clockwise.
Low Speed Spin
High Speed Spin
Inlet valve for main water turns on.
Inlet valve for hot water turns on.
Inlet valve for softener turns on.
Inlet valve for bleach turns on.
Tumble counter clockwise.
Low Speed Spin
High Speed Spin
Inlet valve for main water turns on.
Inlet valve for hot water turns on.
Inlet valve for softener turns on.
Inlet valve for bleach turns on.
Tumble counter clockwise.
Turn on the heater
Displayed 1U XX, 1g XX and 1O XX
alternately (Version)
alternately (Version)
16 times
15 times
12 times
11 times
13 times
14 times
14 times
High Speed Spin
PDA Signal Check
rpm (1000~1150)
This function is not applied in this machine
Displayed 1U XX, 1g XX and 1O XX alternately
Button Checks.
Turns on all lamps.
Drain Pump turns on.
Displayed 1U XX, 1g XX and 1O XX alternately
Water level frequency (26,2~23,0 kHz)
rpm (550~650)
Displayed XX