-16-
652031
652481
652012
652012
652011
ACCESSORY ASS’Y
-4-
SAFETY PRECAUTIONS
BEFORE OPERATION THIS VACUUM CLEANER, READ THIS SERVICE MANUAL THOROUGHLY, AND OBSERVE
EACH POINT CAREFULLY.
1. Change the paper bag or clean the cloth
bag in case the indicator moves toward red.
1) If the dust bag is full, intake power will be reduced.
2) When the dust bag is full of dust, pull out the dust
bag from the inside of body base.
2. Filter
1) The filter is composed of a clean filter, a exhaust filter
and a paper bag or a cloth bag.
2) Never use the vacuum cleaner without filters. It may
harm to the motor.
3) When the cloth bag, the clean filter and the exhaust
filter are soiled, wash the filter with neutral cleanser.
Note : Re-use of the cloth bag, clean filter and exhaust
filter.
• Never wash the filter in a washing machine or in a
dishwasher.
• Never use hot water for washing the filter.
• Re-use the filter after drying it completely in the
shade.
• Do not dry near fire or direct sun ray.
3. Dust indicator
Dust indicator shows red color when the filter is full of
dust.
Then exchange the paper bag with new one or clean
the cloth bag.
4. Avoid suction such materials as:
1) Liquid or wet dust : Clogging the ventilation holes, reduces
the intake power remarkable and harms the motor.
2) Inflammable liquids such as benzene, alcohol or solvents.
3) Burning objects such as cigarette butts.
4) Bulky objects such as vinyl, paper etc.
5) Sharp objects such as needles, pins, metal or glass
particles etc.
5. Attachments
• Nozzle : for cleaning wooden floor, the room floor
and carpet.
• Crevice tool : for cleaning any crevice, inside com-
ers or window frames. However, do not use the
crevice tool more than 20 minutes because it may
cause harm to the motor.
• Dusting brush : for cleaning clothes curtains.
6. Close supervision is necessary when this
vacuum cleaner is used by or near children.
Children's carelessness may cause damage
to the cleaner or injure persons.
7. Air exhausted from the vacuum cleaner is
normally warm. But if extraordinarily air is
exhausted, check if the extension wands,
hose or dust bag is clogged or not.
8. Electric shock could occur if used outdoors
or on wet surfaces.
¡
¡
ÿ
BEFORE ATTEMPTING TO SERVICE OR ADJUST
ANY PART OF THE VACUUM CLEANER, DISCON-
NECT THE ELECTRICAL POWER SUPPLY CORD
FROM THE WALL OUTLET.
1. Motor exchange
1) separate the body cover and body base by unfasten-
ing the screws.
2) Disconnect the lead wires.
3) Lift the old motor and replace it with a new one.
2. In case of exchanging other parts, refer
to the exploded view.
CAUTIONS
BEFORE ATTEMPTING TO SERVICE OR ADJUST ANY PART OF THE VACUUM CLEANER, DISCONNECT THE ELEC-
TRICAL POWER SUPPLY CORD FROM THE WALL OUTLET.
1. Motor exchange
1) separate the body cover and body base by unfastening the screws.
2) Disconnect the lead wires.
3) Lift the old motor and replace it with a new one.
2. In case of exchanging other parts, refer to the exploded view.
-8-
TROUBLE SHOOTING
1 SWITCH ON BUT MOTOR DOES NOT TURN
2. SWITCH ON, MOTOR DOES NOT TURN BUT BUZZES
Poor plug insertion.
Insert again.
Power cord cut.
Repair or exchange.
Interior lead wire cut.
Exchange the lead wire.
Motor (stator armature)coil
cut or damaged.
Exchange the motor.
Poor contact carbon brush
defaced.
Exchange or repair.
Poor switch contact point.
Exchange the switch.
Motor armature cut.
Exchange the motor.
Ball bearing defacement.
Exchange the motor.
Impeller hindrance 
(Caused by foreign matters)
Remove the foreign 
matters.
-9-
3. SWITCH OFF BUT MOTOR TURNS
4. WEAK SUCTION POWER
Poor connections. 
Repair
Poor switch.
Exchange the switch.
Carbon brush defaced.
Exchange the carbon brush
or the motor.
Motor armature cut.
Exchange the motor.
Foreign matters attached to
the impeller
Remove the foreign 
matters.
Low voltage.
Inquire to the power utility
company.
Hose and extension wands
are clogged with foreign
matters.
Remove the foreign matters
in the hose or extension
wands.
Paper bag or cloth bag is
filled with inhaled foreign
matters.
Remove the foreign matters
or exchange the paper bag
or clean the cloth bag.
Low rotation speed.
Motor turns normally,
but suction power is
weak.