- 17 -
Is the LVDS cable 
normal?
Is the VSC Board 
normal?
Is the IC800' operating
normally?
Is the Ctrl Board of 
Module normal?
Is the LVDS cable
connected?
Replace the cable.
Replace the VSC B/D
No
No
Yes
Replace the Ctrl Board
No
Yes
Yes
Yes
No
Re-insert the Cable.
No
Replace FIL8668 IC(IC800).
3. In case of strange screen display in specific modes
3-1. In case of no OSD display
(1) Symptom
1) LED is white.
2) The minute discharge is continuously accomplished from the module.
(2) Procedure check
- 18 -
3-2. In case there is no display on the screen in specific modes
(1) Symptom
1) There is no screen display from a specific input mode
(RF, AV, Component, RGB, DVI).
(2) Procedure check
1) Check the all input modes have normal display.
2) Check the video(main)/ data(sub), video(main)/ video(sub) have normal 
displays from the PIP mode or Double Window mode(re-check it/ swap).
(3) In case of an unusual display in RF mode
Is the Tuner normal?
No
Yes
Yes
Re-insert the cable
Replace the Tuner
Replace the IC611
Is the Tuner Cable
connected?
No
Are the Input voltage,
IIC Communication and HV
sync normal?
No
No
Are the Input voltage,
IIC Communication and CVBS
output normal?
No
No
Is the IC611 
normal?
Replace the IC800
No
Are the Input voltage,
IIC Communication and HV
sync normal?
No
Is the IC800 
normal?
- 19 -
(5) In case of an unusual display in RF , AV mode
(5) In case of an unusual display in Component, RGB mode
(6) In case of an unusual display in HDMI mode
Yes
Replace the IC1200
No
Are the Input voltage,
IIC Communication and HV
sync normal?
No
Is the IC1200 
normal?
Replace the IC800
No
Are the Input voltage,
IIC Communication and HV
sync normal?
No
Is the IC800 
normal?
Replace the IC800
No
Are the Input voltage,
IIC Communication and HV
sync normal?
No
Is the IC800 
normal?
Yes
Replace the IC611
No
Are the Input voltage,
IIC Communication and HV
sync normal?
No
Is the IC611 
normal?
Replace the IC800
No
Are the Input voltage,
IIC Communication and HV
sync normal?
No
Is the IC800 
normal?
- 20 -
4. In case of no sound
(1) Symptom
1) LED is White
2) Screen display appears but there is no sound.
(2) Procedure check
No
No
No
All input(mode)
is no sound?
Is there no sound only
for HDMI?
Is there no sound only
for AV?
Replace the
IC401
Replace the IC401
Replace the IC611
Replace the
VSC B/D
Set speaker on in the menu.
Download  the EDID data
Check the Speaker Cable.
No
Is the Speaker on?
No
Is the speaker
cable normal?
No
Is the IC401
operating normally?
No
Is there no sound only
for RF?
Check the Tuner IN/OUT
No
No
No
Replace the IC402
No
No
No
Check the signal after
IC611 refer to circuit diagram
Is the output 
52nd&53rd of IC611 
normal?
Yes
Yes
Yes
Yes
Yes
Yes
Is the 
IC401 operating
normally?
Is the 
IC402 operating
normally?
Page of 43