LG 60PT100C-WA / 60PT100N (CHASSIS:PC11A) Service Manual ▷ View online
▶ Color analyzer(CA-210) Setting
1.2 Change the measuring bar “0-CAL”
8-1. White balance adjustment
1.1 Power On
1.3 Press the “0-CAL” button
1.4 Change the measuring bar “MEAS”
Make measuring bar touch on the SET
Signal input : 1360x768@60Hz, 216 Gray level
8-1. White balance adjustment
▶ Equipment Connection
8-1. White balance adjustment
White Balance Adjustment (Manual adjustment)
▶ Test Equipment: CA-210
- Using PDP color temperature, Color Analyzer (CA-210) must use CH 10, which Matrix
compensated (White, Red, Green, Blue compensation) with CS-2100. See the Coordination bellowed one.
▶ Manual adjustment sequence is like bellowed one.
- Press Menu key, and move OPTION
- Press “5” key Press 7 times.
8-1. White balance adjustment
0.329±0.002
0.313±0.002
CA-210
WARM
0.293±0.002
0.285±0.002
CA-210
MEDIUM
0.283±0.002
0.276±0.002
CA-210
COOL
y
x
Color Coordination
Test Equipment
Color temperature
▶ Let CA-210 to zero calibration and must has no gap center of PDP module when adjustment.
- Adjust at three mode (Cool, Medium, Warm)
- If “
- If “
cool
” mode Let B-Gain to 192 and R, G, B-Cut to 64 and then control R, G gain adjustment
High Light adjustment.
- If “
Medium
” and “
Warm
” mode Let R-Gain to 192 and R, G, B-Cut to 64 and then control G, B gain adjustment
High Light adjustment.
- All of the three mode Let R-Gain to 192 and R, G, B-Cut to 64 and then control G, B gain adjustment
High Light adjustment.
- With volume button (+/-) you can adjust.
Attachment: White Balance adjustment coordination and color temperature
※ Using CA-210 Equipment. (10 CH)
Contrast value: 216 Gray
Click on the first or last page to see other 60PT100C-WA / 60PT100N (CHASSIS:PC11A) service manuals if exist.