- 13 -
A
Standard color coordinate and temperature using CA-
210(CH 9)
4.4. Local Dimming Function Check
Step 1) Turn on TV.
Step 2) At the Local Dimming mode, module Edge Backlight
moving right to left Back light of IOP module moving.
Step 3) Confirm the Local Dimming mode.
Step 4) Press “exit” key
4.5. V-COM Adjust(Only LGD(M+S) Module)
- Why need Vcom adjustment?
A
The Vcom (Common Voltage) is a Reference Voltage of
Liquid Crystal Driving.
-> Liquid Crystal need for Polarity Change with every frame.
- Adjust sequence
A
Press the PIP key of the ADJ remote control. (This PIP
key is hot key to enter the VCOM adjusting mode)
(Or After enter Service Mode by pushing “ADJ” key, then
Enter V-Com Adjust mode by pushing “
G
” key at “10.V-Com”)
A
As pushing the right or the left button on the remote
control, And find the V-COM value Which is no or
minimized the Flicker.
(If there is no flicker at default value, Press the exit key
and finish the VCOM adjustment.)
A
Push the OK key to store value. Then the message
“Saving OK” is pop.
A
Press the exit key to finish VCOM adjustment.
4.6. Magic Motion Remote control test
- Equipment : RF Remote control for test, IR-KEY-Code
Remote control for test
- You must confirm the battery power of RF-Remote control
before test(recommend that change the battery per every lot) 
- Sequence (test)
1) if you select the ‘start key(Mute)’ on the controller, you
can pairing with the TV SET.
2) You can check the cursor on the TV Screen, when select
the ‘OK’ Key on the controller 
3) You must remove the pairing with the TV Set by select
‘Vol+(STOP) Key’ on the controller
4.7. 3D function test
(Pattern Generator MSHG-600, MSPG-6100 [Support HDMI 1.4])
* HDMI mode No. 872, pattern No. 83)
1) Please input 3D test pattern like below
2) When 3D OSD appear automatically, then select OK button.
3) Don’t wear a 3D Glasses, Check the picture like below.
Mode
Color Coordination
Temp
∆UV
x
y
COOL
0.269 ± 0.002
0.273 ± 0.002 13000 K
0.0000
MEDIUM
0.285 ± 0.002
0.293 ± 0.002
9300 K
0.0000
WARM
0.313 ± 0.002
0.329 ± 0.002
6500 K
0.0000
Local Dimming Demo (Edge LED Model)
Local Dimming Demo (IOP & ALEF Model)
Row  Li ne
Column  Line
C
LC
C
ST
Pane l
S
Y
S
T
E
M
Gat
e
 Driv
e
 IC
So urce D r i v e  I C
Circuit Block
Ti m i n g  
Co nt r o ll e r
Po w e r  
Blo ck
V
COM
Ga mma
Re f e r e nce V o ltage
Gamm a Reference
Volta ge
Data (R ,G,B ) & C ont ro l s ignal
Con t rol si gnal
Data (R ,G,B ) &
Con t rol si gnal
In
te
rf
a
c
e
TFT
Po w e r  I n p u t
Power Input
Da t a  I n p u t
Da t a  I n p u t
V
COM
Liquid 
Crys tal
V
COM
[Visual Adjust and control the Voltage level]
- 14 -
4.8. IR emitter inspection
(1) Start 3D pattern inspection
(2) If IR emitter emitter signal is correctly received to IR
receiver, the lamp of IR tester turn on
4.9. Option selection per country
(1) Overview
- Option selection is only done for models in Non-EU.
- Applied model: LD03S Chassis applied EU model.
(2) Method
1) Press ADJ key on the Adj. Remote Control, then select
Country Group Menu.
2) Depending on destination, select Country Group Code
04 or Country Group EU then on the lower Country
option, select US, CA, MX. Selection is done using +, -
or 
GF
KEY.
4.10. Tool Option selection
- Method : Press Adj. key on the Adj. Remote Control, then
select Tool option.
4.11. Ship-out mode check(In-stop)
After final inspection, press IN-STOP key of the Adj. R/C and
check that the unit goes to Stand-by mode.
* After final inspection, Always turn on the Mechanical S/W.
5.1. Method
- Check that Power Cord is fully inserted to the SET.
(If loose, re-insert)
- Unit fully inserted Power cord, Antenna cable and A/V
arrive to the auto-check process. 
- Connect D-terminal to AV JACK TESTER
- Auto CONTROLLER(GWS103-4) ON
- Perform GND TEST
- If NG, Buzzer will sound to inform the operator.
- If OK, changeover to I/P check automatically.
(Remove CORD, A/V form AV JACK BOX)
- Perform I/P test
- If NG, Buzzer will sound to inform the operator.
- If OK, Good lamp will lit up and the stopper will allow the
pallet to move on to next process.
5.2. Checkpoint
• TEST voltage
- GND: 1.5 KV/min at 100 mA
- SIGNAL: 3 KV/min at 100 mA
• TEST time: 1 second
• TEST POINT
- GND TEST = POWER CORD GND & SIGNAL CABLE
METAL GND
NEUTRAL
• LEAKAGE CURRENT: At 0.5 mArms
6. Audio
Measurement condition:
1. RF input: Mono, 1 KHz sine wave signal, 100 % Modulation
2. CVBS, Component: 1 KHz sine wave signal 0.4 Vrms
3. RGB PC: 1 KHz sine wave signal 0.7 Vrms
<IR Tester Lamp turned off(NG)>
<IR Emitter inspection>
<IR Tester Lamp turned on(OK)>
No.
Item
Min. Typ. Max. Unit
1.  Audio practical max
7
W
EQ Off
Output, L/R
AVL Off
(Distortion=10 %
Vrms Clear Voice Off
max Output)
2. Speaker 
(8 
10.0 15.0
W
EQ On
Impedance)
AVL On
Clear Voice On
- 15 -
7. USB S/W Download (option, Service only)
1) Put the USB Stick to the USB socket 
2) Automatically detecting update file in USB Stick
- If your downloaded program version in USB Stick is Low,
it didn’t work. But your downloaded version is High, USB
data is automatically detecting
3) Show the message “Copying files from memory”
4) Updating is starting.
5) Updating Completed, The TV will restart automatically
6) If your TV is turned on, check your updated version and
Tool option. (explain the Tool option, next stage)
* If downloading version is more high than your TV have,
TV can lost all channel data. In this case, you have to
channel recover. if all channel data is cleared, you didn’t
have a DTV/ATV test on production line.
* After downloading, have to adjust TOOL OPTION again.
1) Push "IN-START" key in service remote control.
2) Select "Tool Option 1" and Push “OK” button.
3) Push in the number. (Each model has their number.)
- 16 -
BLOCK DIAGRAM
Page of 57
Display