- 17 -
8. Adjustment of White Balance
Caution: Press the POWER ON KEY on R/C before W/B adjustment.
8-1. Test Equipment
- Color Analyzer (CS-1000, CA-100+(CH.10), CA-210(CH.10))
[ Please adjust CA-100+ / CA-210 by CS-1000 before measuring
--> You should use Channel 10 which is Matrix compensated
(White, Red, Green, Blue revised) by CS-1000 and adjust
in accordance with White balance adjustment coordinate.
O
Color temperature standards according to CSM and Module 
O
Change  target  luminance  and  range  of  the  Auto  adjustment
W/B equipment.
O
White balance adjustment coordinate and color temperature
8-2. Connecting Picture of the Measuring 
Instrument
(On Automatic control )
Inside PATTERN is used when W/B is controlled. Connect to
auto  controller  or  push  control  R/C  ADJ  Key—>  Enter  the
mode of White-Balance, the pattern will come out.
8-3. Auto-control Interface and Directions
(1)  Adjust  in  the  place  where  the  influx  of  light  like  floodlight
around is blocked. (illumination is less than 10ux).
(2) In case of PDP: Measure and adjust after sticking the Color
Analyzer (CA-100+, CA210) to the side of the module. 
In  case  of  LCD:  Adhere  closely    the  Color  Analyzer  (
CA210)  to  the  module  less  than  10cm  distance,  keep  it
with the surface of the Module and Color Analyzer’s Prove
vertically.(80~100°).
(3) Aging time  
1)  After  aging  start,  keep  the  power  on  (no  suspension  of
power supply) and heat-run over 5 minutes.
2) In case of PDP, keep white pattern using inside pattern.
3) In case of LCD, using ’no signal’ or ‘full white pattern’ or
the others, check the back light on.
O
Auto Adjustment Map(RS-232C)
ADJUSTMENT INSTRUCTIONS
0.003
0.003
0.003
[ PC (for communication through RS-232C) ==> UART Baud rate : 115200 bps
3uv
0.329±0.002
0.329±0.002
0.329
y
0.313±0.002
0.313±0.002
0.313
x
CA-210 (CH.10)
CA-100+ (CH.10)
CS-1000
Warm
0.000
0.000
0.000
3uv
0.293±0.002
0.293±0.002
0.293
y
0.285±0.002
0.285±0.002
0.285
x
CA-210 (CH.10)
CA-100+ (CH.10)
CS-1000
Medium
0.000
0.000
0.000
3uv
0.283±0.002
0.283±0.002
0.283
y
0.276±0.002
0.276±0.002
0.276
x
CA-210 (CH.10)
CA-100+ (CH.10)
CS-1000
Cool
- 18 -
8-4. Manual White Balance 
(1)  Press  the  POWER  ON  KEY  on  R/C  for  adjustment  and
heat run over 5 minutes.
(2)  Zero  Calibrate  CA-100+  /  CA-210,  and  when  controlling,
stick the sensor to the center of PDP module surface.
(3) Press the ADJ KEY on R/C and enter EZ ASJUST
Select “3.W/B ADJUST” and press ENTER(
V
)
Set test-pattern on and display inside pattern. 
(4) Control is carried out on three color temperatures, COOL,
MEDIUM, WARM.(Control is carried out three times)
<Temperature: COOL>
- R-offset / G-offset / B-offset is set to 128
- Control R-Gain and G-Gain.
- Each gain is limited to 192
<Temperature: MEDIUM>
- R-offset / G-offset / B-offset is set to 128
- Control R-Gain and G-Gain.
- Each gain is limited to 192
<Temperature: WARM>
- R-offset / G-offset / B-offset is set to 128
- Control G-Gain and B-Gain.
- Each gain is limited to 192
9. HDCP SETTING
(Not necessary) 
Caution: Key is saved in external eeprom. 
10. RS-232C 
Press  In-start  key  and  select  4.Baud  Rate  menu.  Check  RS-
232C after changing Baud Rate 115200.
11. TOOL OPTION
11-1. Using DFT(Auto)
PC  (for  communication  through  RS-232C)  ==>  UART  Baud
rate : 115200 bps
Command : ab 00 00 DATA(Model Number(hexadecimal))
11-2. Setting Manual
Press  ADJ  R/C  In-start  key  and  select  0.TOOL  OPTION,
Select Model Number by using R/C number(0~9) key or select
Model  Number  by  using 
F
/
G
(VOL  +/-)  in  accordance  with
destination.
Finally press 
9
(enter) key.
12. AREA OPTION
12-1. Using DFT(Auto)
PC  (for  communication  through  RS-232C)  ==>  UART  Baud
rate : 115200 bps
Command : ah 00 00 DATA(Area Number(hexadecimal))
12-2. Setting Manual
Press  ADJ  R/C  In-start  key  and  select  1.AREA  OPTION,
Select  Model  Number  by  using 
F
/
G
(VOL  +/-)  in  accordance
with destination
ADJUSTMENT INSTRUCTIONS
- 19 -
TROUBLE SHOOTING GUIDE
- 20 -
TROUBLE SHOOTING GUIDE