LG 50PQ1100-ZE (CHASSIS:PD92A) Service Manual ▷ View online

- 9 -
5. EDID(The Extended Display
Identification Data) Download
(1) Press the ADJ KEY on R/C and enter EZ ADJUST.
(2)  Select  “5.EDID  D/L”  by  using 
D
/
E
(CH  +/-)  and  press
ENTER(
V
).
(3) Select “Start” and press navigation key(
G
).
(4) EDID download is executed automatically.
(5) Press EXIT key on R/C
5.1.  EDID DATA
1) Analog RGB
O
Detail EDID Options are below (
ⓐ, ⓑ, ⓒ, ⓓ)
ⓐ Product ID   
ⓑ Week, Year
=> Controlled on production line:  
ex)  Week: ‘03’  ->  ‘03’ 
Year:  ‘2006’ ->  ‘10’
ⓒ Model Name(Hex)
ⓓ Checksum: Changeable by total EDID data.
2) HDMI
O
Detail EDID Options are below (
ⓐ, ⓑ, ⓒ, ⓓ, ⓔ)
ⓐ Product ID 
ⓑ Week, Year
=> Controlled on production line:  
ex)  Week: ‘03’  ->  ‘03’ 
Year:  ‘2009’ ->  ‘13’
ⓒ Model Name(Hex)
ⓓ Checksum: Changeable by total EDID data.
ⓔ Vender ID
* In case of 42/50PQ1000, 1100, HDMI 1 is ONLY applied.
Product ID 
MODEL NAME 
Product ID 
HEX 
EDID Table 
42PQ3000 
40433 
9DF1 
F19D 
42PQ6000 
40431 
9DEF 
EF9D 
50PQ3000 
50250 
C44A 
4AC4 
50PQ6000 
50248 
C448 
48C4 
42PQ2000 
40467 
9E13 
139E 
50PQ2000 
50276 
C464 
64C4 
50PS3000 
50278 
C466 
66C4 
50PS6000 
50280 
C468 
68C4 
60PS4000 
50290 
C472 
72C4 
42PQ1000 
40473 
9E19 
199E 
42PQ1100 
40475 
9E1B 
1B9E 
50PQ1000 
50296 
C478 
78C4 
Product ID 
MODEL NAME 
Product ID 
HEX 
EDID Table 
42PQ3000 
40433 
9DF1 
F19D 
42PQ6000 
40431 
9DEF 
EF9D 
50PQ3000 
50250 
C44A 
4AC4 
50PQ6000 
50248 
C448 
48C4 
42PQ2000 
40467 
9E13 
139E 
50PQ2000 
50276 
C464 
64C4 
50PS3000 
50278 
C466 
66C4 
50PS6000 
50280 
C468 
68C4 
60PS4000 
50290 
C472 
72C4 
42PQ1000 
40473 
9E19 
199E 
42PQ1100 
40475 
9E1B 
1B9E 
50PQ1000 
50296 
C478 
78C4 
- 10 -
5.2 Confirmation
1) Press ‘InStart’ Key on Factory SVC Remote Controller, It is
possible to check ADC & EDID ADJ
2) Select “Channel Recovery” and press navigation key(
G
).
6. SET assembly adjustment method
Caution : Each PCB assembly must be checked by check JIG set.
(Because  power  PCB  Assembly  damages  to  PDP  Module,
especially be careful)
7. POWER PCB Assembly Voltage 
Adjustment
(Va, Vs voltage Adjustment)
7.1. Test Equipment
:
D.M.M 1EA
7.2. Connection Diagram for Measuring:
Refer to fig.1
7.3. Adjustment Method
(1) Va adjustment 
1)  Connect + terminal of D. M.M. to Va pin of P811, connect -
terminal to GND pin of P811.
2)  After turning VR901,voltage of D.M.M adjustment as same
as Va voltage which on label of panel right/top  (deviation;
±0.5V)
(2) Vs adjustment 
1)  Connect + terminal of D. M..M. to Vs pin of P811, connect
-terminal to GND pin of P811.
2)  After turning VR951, voltage of D.M.M adjustment as same
as Vs voltage which on label of panel right/top  (deviation ;
±0.5V)
8. Download Serial Number (RS-232C)
(1) Press “Power on” key of service R/C.(Baud rate : 115200
bps)
(2) Connect RS232 Signal Cable to RS-232 Jack.
(3) Write Serial number by use RS-232.
(4)  Must  check  the  serial  number  at  the  Diagnostics  of  SET
UP menu. 
(Refer to below ‘6.SET INFORMATION’).
9. Adjustment of White Balance
9.1. Required Equipment
(1) Remote controller for adjustment 
(2)  Color  Analyzer  (CS-1000,  CA-100,100+,CA-210  or  same
product) : CH 10 (PDP) 
[ Please  adjust  CA-210,  CA-100+  by  CS-1000  before
measuring
(3) Auto W/B adjustment instrument(only for Auto adjustment)
(4) 9 Pin D-Sub Jack(RS232C) is connected to the AUTO W/B
EQUIPMENT.
9.2. AUTO White Balance Process
Before Adjust of White Balance, Please press POWER ONLY
key
Adjust Process will start by execute RS232C Command
O
Color temperature standards according to CSM and Module 
O
CS-1000/CA-100+/CA-210(CH  10)  White  balance
adjustment coordinates and color temperature.
PLASMA
Remark
11000K
9300K
6500K
Cool
Medium
Warm
CSM
Color Coordinate
x
0.283
0.293
0.329
11,000K
9,300K
6,500K
0.002
0.002
0.002
0.276
0.285
0.313
Cool
Medium
Warm
CSM
Temp
±Color 
Coordinate
- 11 -
9.3. Manual W/B Process 
(using adjusts Remote control)
Please Adjust in AV 1 MODE, Turn off Energy Saving Mode.
(1)  Enter  “PICTURE  RESET”  on  Picture  Mode,  then  turn  off
Fresh Contrast and Fresh colour in Advanced Control
(2) After enter Service Mode by pushing “ADJ” key,
(3) Enter White Pattern off of service mode, and change off ->
on.
(4)  Enter  “W/B  ADJUST”  by  pushing  “
G
”  key  at  “3.  W/B
ADJUST”. 
(5) Adjust W/B DATA, for all CSM, choose ‘COPY ALL’
[ Gain  Max  Value  is  192.  So,  Never  make  any  Gain  Value
over  192  and  please  fix  one  Value  on  192,  between  R,  G
and B.
9.4. Auto-control Interface and Directions
(1)  Adjust  in  the  place  where  the  influx  of  light  like  floodlight
around is blocked.
(Illumination is less than 10ux).
(2) Measure and adjust after sticking the Color Analyzer (CA-
100+, CA210 ) to the side of the module. 
(3) Aging time  
After  aging  start,  keep  the  Power  on  (no  suspension  of
power supply) and heat-run over 5 minutes 
9.5. Auto Adjustment Map(RS232C)
10. Checking the EYE-Q Operation
(1) Press the EYE Key on the adjustment remote controller.
(2)  Check  the  Sensor  DATA  (It  must  be  under  10)  and  keep
the data longer than 1.5s
(3) Check ‘OK’
(Sensor DATA 0 ~ 4095, Power Saving Mode 0 ~ 12)
[ IF you press IN-STAP Button, change Green Eye-check OSD.
11. Set Information
(Serial No & Model name)
11.1. Check the Serial Number & Model Name
(1) Push the menu button in DTV mode.    
(2) Check the Serial Number            
Select the STATION ==> Diagnostics ==> To set
12. SW Download Guide.
* Put a *.bin to USB Stick and Turn on TV
1. Put the USB Stick to the USB socket
2. Automatically detecting update file in USB Stick
* If  your  downloaded  program  version  in  USB  Stick  is  Low,  it
didn’t work.
But  your  downloaded  version  is  High,  USB  data  is
automatically detecting.
3. Show the message “Copying files from memory”
4. Updating is staring.
5. Updating Completed, The TV will restart automatically.
After  turn  on  TV,  Please  press  ‘IN-STOP’  button  on  ADJ
Remote-control.
*  IF  you  don’t  have  ADJ  R/C,  enter  ‘Factory  Reset’  in  OPTION
MENU.
6. When  TV  turn  on,  check  the  Updated  version  on  Diagnostics
MENU.
- 12 -
 
 
 
 
 