LG 50PG3HFD-UA (CHASSIS:PU84C) Service Manual ▷ View online
- 9 -
7. Adjustment of White Balance
Caution: Press the POWER ON KEY on R/C before W/B adjustment.
7-1. Test Equipment
- Color Analyzer (CS-1000, CA-100+(CH.10), CA-210(CH.10))
[
Please adjust CA-100+ / CA-210 by CS-1000 before measuring
--> You should use Channel 10 which is Matrix compensated
(White, Red, Green, Blue revised) by CS-1000 and adjust
in accordance with White balance adjustment coordinate.
in accordance with White balance adjustment coordinate.
O
Color temperature standards according to CSM and Module
O
Change target luminance and range of the Auto adjustment
W/B equipment.
O
White balance adjustment coordinate and color temperature
7-2. Connecting Picture of the Measuring
Instrument
(On Automatic control )
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push control R/C ADJ Key—> Enter the
mode of White-Balance, the pattern will come out.
auto controller or push control R/C ADJ Key—> Enter the
mode of White-Balance, the pattern will come out.
7-3. Auto-control Interface and Directions
(1) Adjust in the place where the influx of light like floodlight
around is blocked. (illumination is less than 10ux).
(2) In case of PDP: Measure and adjust after sticking the Color
Analyzer (CA-100+, CA210) to the side of the module.
In case of LCD: Adhere closely the Color Analyzer (
CA210 ) to the module less than 10cm distance, keep it
with the surface of the Module and Color Analyzer’s Prove
vertically.(80~100°).
CA210 ) to the module less than 10cm distance, keep it
with the surface of the Module and Color Analyzer’s Prove
vertically.(80~100°).
(3) Aging time
1) After aging start, keep the power on (no suspension of
power supply) and heat-run over 5 minutes.
2) In case of PDP, keep white pattern using inside pattern.
3) In case of LCD, using ’no signal’ or ‘full white pattern’ or
3) In case of LCD, using ’no signal’ or ‘full white pattern’ or
the others, check the back light on.
O
Auto Adjustment Map(RS-232C)
7-4. Manual White Balance
1) Press the POWER KEY on R/C for adjustment and heat
run over 5 minutes.
2) Zero Calibrate CA-100+ / CA-210, and when controlling,
stick the sensor to the center of PDP module surface.
3) Press the ADJ KEY on R/C and enter EZ ASJUST
Select “3. W/B ADJUST” and press ENTER(
A
).
Set test-pattern on and display inside pattern.
4) Control is carried out on three color temperatures, COOL,
MEDIUM, WARM.
(Control is carried out three times)
(Control is carried out three times)
<Temperature: COOL>
- R-offset / G-offset / B-offset is set to 128
- Control R-Gain and G-Gain.
- Each gain is limited to 192
- Control R-Gain and G-Gain.
- Each gain is limited to 192
<Temperature: MEDIUM>
- R-offset / G-offset / B-offset is set to 128
- Control R-Gain and G-Gain.
- Each gain is limited to 192
- Control R-Gain and G-Gain.
- Each gain is limited to 192
<Temperature: WARM>
- R-offset / G-offset / B-offset is set to 128
- Control G-Gain and B-Gain.
- Each gain is limited to 192
- Control G-Gain and B-Gain.
- Each gain is limited to 192
- 10 -
8. HDCP(High-Bandwidth Digital
Contents Protection) SETTING
(1) Connect D-sub Signal Cable to D-Sub Jack
(2) Input HDCP key with HDCP-key- in-program
(3) HDCP Key value is stored on EEPROM(AT24C512) which
(2) Input HDCP key with HDCP-key- in-program
(3) HDCP Key value is stored on EEPROM(AT24C512) which
is 80~A1 addresses of 0xA0~0xA2 page
(4) AC off/ on and on HDCP button of MSPG925 and confirm
whether picture is displayed or not of using MSPG925
(5) HDCP Key value is different among the sets.
9. RS-232C
Press In-start key and select 3.Baud Rate menu. Check RS-
232C after changing Baud Rate 115200.
232C after changing Baud Rate 115200.
10. OPTION
(1) Press ADJ R/C In-start key and select 0.AREA OPTION
(2) Select Country by using
(2) Select Country by using
F
/
G
(VOL +/-) in accordance with
destination
- 11 -
GUÍA PARA SOLUCIONES DE PROBLEMAS
- 12 -
Power-Up Boot Fail Trouble Shooting
Check P701 All
Voltage Level (16V, 5V)
Check Power connector
OK ?
Replace Power board
Y
N
Y
Check IC706 #2 Pin
Voltage Level 2.6V
Replace IC706 &
Recheck
Y
N
Check X100 Clock
12MHz
Replace 100
Y
N
Replace IC105 Flash Memory
Check Q706 Output
Voltage Level (5V)
Replace Q801
N
Y
Click on the first or last page to see other 50PG3HFD-UA (CHASSIS:PU84C) service manuals if exist.