- 21 -
3) Press the IN-START key on R/C for adjustment.
[Fig.3]
4) Press  the 
(Vol.+) key to operate the set , then it
becomes automatically.
5) After downloading complete, the ‘OK’ word
appears.
6) Auto-RGB OK means adjustment is completed.
7. White Balance
* Test Equipment
Color Analyzer (CA-210, CA-100+ / CH.9)
-> When you adjust LCD color temperature, on Color
analyzer (CA-210, CA-100+), you should use Channel 9
which is Matrix compensated (White, Red, Green, Blue
revised) by CS-1000 and adjust in accordance with
White balance adjustment coordinate which is specified
on the next.
* Color temperature standards according to CSM and Module.
* White balance adjustment coordinate and color temperature.
PC (for communication through RS-232C) -> UART
Baud rate : 115200 bps
* Connecting picture of the measuring instrument (On
Automatic control )
Inside PATTERN is used when W/B is controlled.
Connect to auto controller or push control R/C IN-START
-> Enter the mode of White-Balance, the pattern will come
out.
[Fig.4] connecting picture (On Automatic Control)
* Auto-control interface and directions
1) Adjust in the place where the influx of light like floodlight
around is blocked. (illumination is less than 10ux).
2) In case of PDP: Measure and adjust after sticking the
Color Analyzer (CA-100+, CA210 ) to the side of the
module. 
In case of LCD: Adhere closely  the Color Analyzer (
CA210 ) to the module less than 10cm distance, keep it
with the surface of the Module and Color Analyzer’s
Prove vertically.(80~100°).
3) Aging time
- After aging start, keep the power on (no suspension of
power supply) and heat-run over 15 minutes.
- In case of PDP, keep white pattern using inside pattern.
- In case of LCD, using ‘no signal’ or ‘full white pattern’ or
the others, check the back light on.
7.1 Auto white Balance
1) setup is done.
2) Test Equipment
Color Analyzer ( CA210, CA-100+)
PC (for communication through RS-232C)  
RS-232 Host Ë PC
UART Baud rate Ë 115200
Download Ë Cortez
*** When press Power-on key, this point is automatically
setuped. Pattern Generator (MSPG-925F)
7.2 Manual white Balance 
* One of R Gain / G Gain / B Gain should be kept on 80,
and others are controlled lowering from 80 
1) Press "power on°" of the control R/C, set heat run to
white by pressing 
, and heat run over 15 minutes 
(Set : RS-233 Host : PC, Baud Rate : 115200bps,
Download: Cortez).
2) Zero Calibrate CA-100+, and when controlling, stick the
sensor to the center of LCD module surface.
3) Double click In-start key on Controlling R/C and get in
‘white balance’.
4) Set test-pattern on and display inside pattern. Control is
carried out on three color temperature, COOL, MEDIUM,
WARM. (Control is carried out three times,)
CSM
LCD
Cool
11,000k
Medium
9,300k
Warm
6,500k
Cool
CS-1000
CA-210 (CH 9)
CA-100+ (CH 9)
X
0.276
0.002
0.276
0.002
0.276
0.002
Y
0.283
0.002
0.283
0.002
0.283
0.002
Temp
11000
1000
11000
uv
0.000
0.000
0.000
Medium
CS-1000
CS-1000
CS-1000
X
0.285
0.002
0.285
0.002
0.285
0.002
Y
0.293
0.002
0.293
0.002
0.293
0.002
Temp
9300
9300
9300
uv
0.000
0.000
0.000
Warm
CS-1000
CS-1000
CS-1000
X
0.313
0.002
0.313
0.002
0.313
0.002
Y
0.329
0.002
0.329
0.002
0.329
0.002
Temp
6500
6500
6500
Temp
0.003
0.003
0.003
- 22 -
5) When the R/G/B GAIN is 80 on OSD, it is the FULL
DYNAMIC Range of the Module. In order to control white
balance without the saturation of FULL DYNAMIC Range
and DATA, one of R Gain / G Gain / B Gain should be
kept on 80, and other two is controlled lowering from 80.
* Color Temperature: Cool, Medium, Warm
1. When R GAIN is set to 80
- Control G GAIN and B GAIN by lowering from 80. 
2. When B GAIN is set to 80
- Control R GAIN and G GAIN by lowering from 80.
3. When G GAIN is set to 80
- Control R GAIN and B GAIN by lowering from
192.
One of R Gain / G Gain / B Gain should be kept on
80, and adjust other two lower than 80.
(When R/G/B GAIN are all 80, it is the FULL
DYNAMIC Range of Module) 
8. Set Information(Serial No & Model
name)
1) Setting up like bottom figure(After setting white balance,
this is set)
(Setting: Press ADJ Key in the Adjust remocon.
Select "System Control 2" by using 
/
(CH+/-) key,
and press 
(ENTER)
Using Adjust remocon, RS-232 Host & Baud Rate &
Download value change)
- 23 -
TROUBLESHOOTING
1. No power
(1) Symptom
1) Doesn't minute discharge at module.
2) Non does not come in into the front LED.
(2) Check follow
Plug in power cord
No
Yes
Is plug in power cord? 
Connect cable.
No
Is connect the Line
Filter and Power
Board Cable?
Replace fuse.
No
Is normal the
Fuse(F100) on Power
Board?
Connect Cable.
After remove the cable connect to
Power Board (except the SC100
connection cable), authorizes the
AC voltage marking on manual.
When ST-BY 5V does not operate,
replace Power Board.
No
Is connect the Power
Board and 13P of VSC
Board Cable?
Yes
Yes
Yes
- 24 -
2. Protect mode
(1) Symptom
1) After once shining, it does not discharge minutely from module. 
2) The relay falls.(The sound is audible “Click”.)
3) It is converted with the color where the front LED is red from green.
(2) Check follow
Is normal the Power
Board?
Replace Power Board.
Is output the normality Low/High
voltage except Stand-by 5V?
Yes
No
No
Is normal the each
connector?
Replace connector.
After connecting well each connector,
the normality it operates? 
Yes
No
No
Is normal the VSC
Board?
After remove P900, P901
normal operation: 
Replace VSC Board
Is normal the output voltage after
remove P900, P901 of VSC Board?
No
Yes
Page of 55
Display