DOWNLOAD LG 47LM6400 (CHASSIS:LT22E) Service Manual ↓ Size: 14.11 MB | Pages: 127 in PDF or view online for FREE

Model
47LM6400 (CHASSIS:LT22E)
Pages
127
Size
14.11 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD
File
47lm6400-chassis-lt22e.pdf
Date

LG 47LM6400 (CHASSIS:LT22E) Service Manual ▷ View online

- 3 -
Many electrical and mechanical parts in this chassis have special safety-related characteristics. These parts are identified by      in the 
Schematic Diagram and Exploded View.
It is essential that these special safety parts should be replaced with the same components as recommended in this manual to prevent 
Shock, Fire, or other Hazards. 
Do not modify the original design without permission of manufacturer.
General Guidance
An 
isolation  Transformer  should  always  be  used  during  the 
servicing of a receiver whose chassis is not isolated from the AC 
power  line.  Use  a  transformer  of  adequate  power  rating  as  this 
protects  the  technician  from  accidents  resulting  in  personal  injury 
from electrical shocks.
It  will  also  protect  the  receiver  and  it's  components  from  being 
damaged  by  accidental  shorts  of  the  circuitry  that  may  be 
inadvertently introduced during the service operation.
If  any  fuse  (or  Fusible  Resistor)  in  this  TV  receiver  is  blown, 
replace it with the specified.
When replacing a high wattage resistor (Oxide Metal Film Resistor, 
over 1 W), keep the resistor 10 mm away from PCB.
Keep wires away from high voltage or high temperature parts.
Before returning the receiver to the customer, 
always  perform  an 
AC  leakage  current  check  on  the  exposed 
metallic parts of the cabinet, such as antennas, terminals, etc., to 
be  sure  the  set  is  safe  to  operate  without  damage  of  electrical 
shock. 
Leakage Current Cold Check(Antenna Cold Check)
With the instrument AC plug removed from AC source, connect an 
electrical  jumper  across  the  two AC  plug  prongs.  Place  the AC 
switch in the on position, connect one lead of ohm-meter to the AC 
plug prongs tied together and touch other ohm-meter lead in turn to 
each  exposed  metallic  parts  such  as  antenna  terminals,  phone 
jacks, etc. 
If  the  exposed  metallic  part  has  a  return  path  to  the  chassis,  the 
measured resistance should be between 1 M
Ω and 5.2 MΩ. 
When  the  exposed  metal  has  no  return  path  to  the  chassis  the 
reading must be infinite.
An  other  abnormality  exists  that  must  be  corrected  before  the 
receiver is returned to the customer.
Leakage Current Hot Check 
(See below Figure) 
Plug the AC cord directly into the AC outlet.
Do not use a line Isolation Transformer during this check. 
Connect 1.5 K / 10 watt resistor in parallel with a 0.15 uF capacitor 
between  a  known  good  earth  ground  (Water  Pipe,  Conduit,  etc.) 
and the exposed metallic parts.
Measure  the AC  voltage  across  the  resistor  using AC  voltmeter 
with 1000 ohms/volt or more sensitivity.
Reverse plug the AC cord into the AC outlet and repeat AC voltage 
measurements  for  each  exposed  metallic  part.  Any  voltage 
measured must not exceed 0.75 volt RMS which is corresponds to 
0.5 mA.
In  case  any  measurement  is  out  of  the  limits  specified,  there  is 
possibility  of  shock  hazard  and  the  set  must  be  checked  and 
repaired before it is returned to the customer.
Leakage Current Hot Check circuit 
IMPORTANT SAFETY NOTICE
SAFETY PRECAUTIONS
- 4 -
SPECIFICATION
NOTE : Specifications and others are subject to change without notice for improvement.
1. Application range
This  spec  sheet  is  applied  to  the  32/42/47/55/60/65LCD TV 
used LT22E chassis.
2. Test condition
Each part is tested as below without special notice.
1) Temperature : 25 ºC ± 5 ºC (77 ºF ± 9 ºF), CST : 40 ºC±5 ºC
2) Relative Humidity: 65 % ± 10 %
3) Power Voltage :  Standard  input  voltage  (100~240V@ 
50/60Hz)
4)  Specification  and  performance  of  each  parts  are  followed 
each  drawing  and  specification  by  part  number  in 
accordance with BOM.
5)  The receiver must be operated for about 5 minutes prior to 
the adjustment.
3. Test method
1) Performance: LGE TV test method followed 
2) Demanded other specification 
- Safety : CE, IEC specification
- EMC : CE, IEC 
- 5 -
4. General Specification
No
Item
Specification
Remark
1.
Display Screen Device
32” wide Color Display Module
37” wide Color Display Module
42” wide Color Display Module
47” wide Color Display Module
55” wide Color Display Module
60” wide Color Display Module
65” wide Color Display Module
Resolution: 1920*1080
Resolution: 1920*1080
Resolution: 1920*1080
Resolution: 1920*1080
Resolution: 1920*1080
Resolution: 1920*1080
Resolution: 1920*1080
2.
Aspect Ratio
16:9
All
3.
LCD Module
32” TFT WUXGA LCD
37” TFT WUXGA LCD
42” TFT WUXGA LCD
47” TFT WUXGA LCD
55” TFT WUXGA LCD
60” TFT WUXGA LCD
65” TFT WUXGA LCD
4.
Operating Environment
1) Temp. : 0 ~ 40 deg
LGE SPEC
2) Humidity : 0 ~ 85%
5.
Storage Environment
1) Temp. : -20 ~ 60 deg
2) Humidity : 10 ~ 90%
6.
Input Voltage
AC100 ~ 240V, 50/60Hz
7.
Power Consumption(Max) = 
LCD(Module) + Backlight(LED)
FHD 60Hz
Edge LED
32”
50
W
Normal : T320HVN01.0 [32LS5700-DA/B]
Normal : LC320EUN-SEM1 [32LS5700-DA/B]
42”
70
W
Normal : LC420EUE-SEM1 [42LS5700-DA/B]
47”
85
W
Normal : LC470EUE-SEM1 [47LS5700-DA/B]
55”
W
Normal : LC550EUE-SEM1 [55LS5700-DA/B]
FHD
T120Hz
Edge LED
32”
45
W
FPR : LC320EUN-SEF2 [32LM6200-DA]
50
W
FPR : LC320EUA-KEF1 [32LM6400-DA]
37”
50
W
FPR : LC370EUN-SEF2 [37LM6200-DA]
42”
60
W
FPR : LC420EUE-SEF1 [42LM6200-DA]
60
W
FPR : LC420EUG-KEF1 [42LM6600-DA]
FPR : LC420EUG-KEF1 [42LM6690-DA]
FPR : LC420EUG-KEF1 [42LM6700-DC]
FPR : LC420EUG-KEF1 [42LM6400-DJ]
47”
90
W
FPR : LC470EUE-SEF1 [47LM6200-DA]
70
W
FPR : LC470EUG-KEF1 [47LM6400-DJ]
FPR : LC470EUG-KEF1 [47LM6690-DC]
FPR : LC470EUG-KEF1 [47LM6700-DA]
55”
115
W
FPR : LC550EUE-SEF1 [55LM6200-DA]
70
W
FPR : LC550EUG-KEF1 [55LM6400-DJ]
FPR : LC550EUG-KEF1 [55LM6700-DA]
FHD
M120Hz
Edge LED
65”
230
W
FPR : T645HB01 V0 [65LM6200-DA]
FHD
T240Hz
Edge LED
42”
70
W
FPR : LC420EUH-KEF1 [42LM7600-DA]
47”
90
W
FPR : LC470EUH-KEF1[47LM7600-DA]
55”
120
W
FPR : LC550EUH-KEF1[55LM7600-DA]
- 6 -
8.
LCD Module
Size
Maker
Inch
(H) × (V) × (D)
LGD
32”
727.4 x 429.0 x 22.7
LC320EUN-SEM2
727.4 x 429.0 x 20.0
698.40 x 392.85 x 10.8
37”
837.2 x 490.6 x 22.7
LC370EUN-SEF2 : Edge 3D_T120Hz
42”
960.4 x 560.4 x 17.4
LC420EUE-SEF1 : Edge 3D_T120Hz
LC420EUE-SEM1 : Edge Non-3D_60Hz
968.4 x 564 x 10.8
 
968.4 x 564 x 12.2
 
47”
1070.6 x 622.0 x 22.0
LC470EUE-SEF1 : Edge 3D_T120Hz
LC470EUE-SEM1 : Edge Non-3D_60Hz
1078.6 x 626.0 x 10.8
 
1078.6 x 626.0 x 12.2
 
1054.5 x 600.0 x 1.8
 
1054.5 x 600.0 x 1.8
 
55”
1244.6 x 720.9 x 22.0
LC550EUE-SEF1 : Edge 3D_T120Hz
1228.6 x 711.4 x 20.7
LC550EUG-KEF1 : Edge 3D_T120Hz
LC550EUH-KEF1 : Edge 3D_T240Hz
1220.8 x 693.8 x 1.8
1220.8 x 693.8 x 1.8
AUO
32”
727.4 x 429.0 x 20.0
T320HVN01.0 : Edge Non-3D_60Hz
65”
1508.0 x 878.0 x 12.8
T645HB01 V0 : Edge 3D_M120Hz
Pixel Pitch
Maker
Inch
(H) × (V) × (D)
LGD
32”
0.36375 x 0.36375
LC320EUN-SEF2 : Edge 3D_T120Hz
37”
0.4209 x 0.4209
LC370EUN-SEF2 : Edge 3D_T120Hz
42”
0.4845 x 0.4845
LC420EUE-SEF1 : Edge 3D_T120Hz
LC420EUE-SEM1 : Edge Non-3D_60Hz
47”
0.5415 x 0.5415
LC470EUE-SEF1 : Edge 3D_T120Hz
LC470EUE-SEM1 : Edge Non-3D_60Hz
55”
0.630 x 0.630
LC550EUE-SEF1 : Edge 3D_T120Hz
LC550EUG-KEF1 : Edge 3D_T120Hz
LC550EUH-KEF1 : Edge 3D_T240Hz
AUO
32”
0.36375 x 0.36375
T320HVN01.0 : Edge Non-3D_60Hz
65”
0.744 x 0.744
T645HB01 V0 : Edge 3D_M120Hz
Back Light
LGD
32”
Edge-LED
LC320EUN-SEF2
LC320EUA-KEF1
37”
Edge-LED
LC370EUN-SEF2
42”
Edge-LED
LC420EUE-SEF1
LC420EUG-KEF1
LC420EUE-SEM1
LC420EUH-KEF1
47”
Edge-LED
LC470EUE-SEF1
LC470EUG-KEF1
LC470EUE-SEM1
LC470EUH-KEF1
55”
Edge-LED
LC550EUE-SEF1
LC550EUG-KEF1
LC550EUH-KEF1
AUO
32”
Edge-LED
T320HVN01.0
65”
Edge-LED
T645HB01 V0
Page of 127
Display

Click on the first or last page to see other 47LM6400 (CHASSIS:LT22E) service manuals if exist.