HDMI-3  EDID  table(2D  HD)  -  South  Centural  America
(PT250B/E, PT260E)
RGB  EDID  table(2D  HD)  -  South  Centural  America
(PT250B/E, PT260E)
* See  Working  Guide  if  you  want  more  information  about  EDID
communication.
5-6. Adjustment Color Temperature
(White balance)
(1) Using Instruments
1) Color Analyzer: CA-210 (CH 9)
- Using  LCD  color  temperature,  Color  Analyzer  (CA-
210)  must  use  CH  9,  which  Matrix  compensated
(White,  Red,  Green,  Blue  compensation)  with  CS-
2100. See the Coordination bellowed one. 
2) Auto-adjustment  Equipment  (It  needs  when  Auto-
adjustment  –  It  is  availed  communicate  with  RS-232C  :
Baud rate: 115200) 
3) Video  Signal  Generator  MSPG-925F  720p,  216Gray
(Model: 217, Pattern 78)
(2) Connection Diagram (Auto Adjustment)
1) Using Inner Pattern
2) Using HDMI input
(3) White Balance Adjustment 
- If you can’t adjust with inner pattern, then you can adjust
it using HDMI pattern. You can select option at “Ez-Adjust
Menu  –  7.  White  Balance”  there  items  “NONE,  INNER,
HDMI”. It is normally setting at inner basically. If you can’t
adjust using inner pattern you can select HDMI item, and
you can adjust.
- In manual Adjust case, if you press ADJ button of service
remocon, and enter “Ez-Adjust Menu – 7. White Balance”,
then  automatically  inner  pattern  operates.  (In  case  of
“Inner” originally “Test-Pattern. On” will be selected in The
“Test-Pattern. On/Off”. 
O
Connect all cables and equipments like Pic.5)
O
Set  Baud  Rate  of  RS-232C  to  115200.  It  may  set
115200 orignally.
O
Connect RS-232C cable to set
O
Connect HDMI cable to set
- 9 -
< Connection Diagram for Adjustment White balance >
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0 00 FF FF FF FF FF FF 00 1E 6D 01 00 01 01 01 01
10 01 15 01 03 80 A0 5A 78 0A EE 91 A3 54 4C 99 26
20 0F 50 54 A1 08 00 31 40 45 40 61 40 01 01 01 01
30 01 01 01 01 01 01 64 19 00 40 41 00 26 30 18 88
40 36 00 40 84 63 00 00 1C A0 0F 20 00 31 58 1C 20
50 28 80 11 00 BC 39 20 00 00 00 00 00 00 FD 00 3A
60 3E 1E 53 10 00 0A 20 20 20 20 20 20 00 00 00 FC
70 00 4C 47 20 54 56 0A 20 20 20 20 20 20 20 01 0F
0 02 03 27 F1 4E 02 03 11 12 93 04 15 16 05 14 10
10 1F 22 20 26 15 07 50 09 57 07 68 03 0C 00 30 00
20 B8 2d 00 E3 05 03 01 02 3A 80 18 71 38 2D 40 58
30 2C 45 00 40 84 63 00 00 1E 01 1D 80 18 71 1C 16
40 20 58 2C 25 00 40 84 63 00 00 9E 01 1D 00 72 51
50 D0 1E 20 6E 28 55 00 40 84 63 00 00 1E 00 00 00
60 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
70 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 B2
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0 00 FF FF FF FF FF FF 00 1E 6D 01 00 01 01 01 01
10 01 15 01 03 68 A0 5A 78 0A EE 91 A3 54 4C 99 26
20 0F 50 54 A1 08 00 31 40 45 40 61 40 01 01 01 01
30 01 01 01 01 01 01 64 19 00 40 41 00 26 30 18 88
40 36 00 40 84 63 00 00 1C A0 0F 20 00 31 58 1C 20
50 28 80 11 00 BC 39 20 00 00 00 00 00 00 FD 00 3A
60 3E 1E 53 10 00 0A 20 20 20 20 20 20 00 00 00 FC
70 00 4C 47 20 54 56 0A 20 20 20 20 20 20 20 00 28
RS-232C COMMAND(Commonly apply)
wb 00 00”: Start Auto-adjustment of white balance.
O
“wb 00 10”: Start Gain Adjustment (Inner pattern) 
O
“jb 00 c0” : 
O
O
“wb 00 1f”: End of Adjustment
* If it needs, offset adjustment (wb 00 20-start, wb 00 2f-
end)
O
“wb  00  ff”:  End  of  white  balance  adjustment  (inner
pattern disappear)
Adjustment Mapping information
O
When  Color  temperature  (White  balance)  Adjustment
(Automatically)
- Press  “Power  only  key”  of  service  remocon  and
operate automatically adjustment.
- Set BaudRate to 115200.
O
You must start “wb 00 00” and finish it “wb 00 ff”.
O
If it needs, then adjustment “Offset”.
(4) White Balance Adjustment (Manual adjustment)
1)  Test Equipment: CA-210
- Using  PDP  color  temperature,  Color  Analyzer  (CA-
210)  must  use  CH  10,  which  Matrix  compensated
(White,  Red,  Green,  Blue  compensation)  with  CS-
2100. See the Coordination bellowed one. 
2) Manual adjustment sequence is like bellowed one.
- Turn  to  “Ez-Adjust”  mode  with  press  ADJ  button  of
service remocon.
- Select  “10.Test  Pattern”  with  CH+/-  button  and  press
enter.  Then  set  will  go  on  Heat-run  mode.  Over  30
minutes set let on Heat-run mode.
- Let CA-210 to zero calibration and must has gap more
10cm from center of PDP module when adjustment. 
- Press  “ADJ”  button  of  service  remocon  and  select
“7.White-Balance” in “Ez-Adjust” then press “
G
” button
of navigation key. (When press “
G
” button then set will
go to full white mode)
- Adjust at three mode (Cool, Medium, Warm)
- If “cool” mode 
Let  B-Gain  to  192  and  R,  G,  B-Cut  to  64  and  then
control R, G gain adjustment High Light adjustment.
- If “Medium” and “Warm” mode Let R-Gain to 192 and
R,  G,  B-Cut  to  64  and  then  control  G,  B  gain
adjustment High Light adjustment.
- All of the three mode 
Let  R-Gain  to  192  and  R,  G,  B-Cut  to  64  and  then
control G, B gain adjustment High Light adjustment.
- With volume button (+/-) you can adjust.
- After all adjustment finished, with Enter (_ key) turn to
Ez-Adjust  mode.  Then  with  ADJ  button,  exit  from
adjustment mode
* Attachment:  White  Balance  adjustment  coordination  and  color
temperature.
O
Using CS-1000 Equipment. 
- COOL : T=11000K, _uv=0.000, x=0.276 y=0.283 
- MEDIUM  : T=9300K, _uv=0.000, x=0.285 y=0.293 
- WARM  : T=6500K, _uv=0.000, x=0.313 y=0.329 
O
Using CA-210 Equipment. (10 CH)
- Contras value : 216 Gray
- Brighness spec.
- 10 -
RS-232C COMMAND
[CMD    ID      DATA]
Meaning
wb
00
00
White Balance adjustment start.
wb
00
10
Start of adjust gain 
(Inner white pattern)
wb
00
1f
End of gain adjust
wb
00
20
Start of offset adjust
(Inner white pattern)
wb
00
2f
End of offset adjust
wb
00
ff
End of White Balance adjust
(Inner pattern disappeared)
RS-232C COMMAND
CENTER
[CMD ID DATA]
MIN
(DEFAULT)
MAX
Cool Mid
Warm
Cool
Mid
Warm
R Gain
jg
Ja
jd
00
184
192
192
192
G Gain
jh
Jb
je
00
187
183
159
192
B Gain
ji
Jc
jf
00
192
161
95
192
R Cut
64
64
64
127
G Cut
64
64
64
127
B Cut
64
64
64
127
Color 
Test 
Color Coordination
temperature
Equipment
x
y
COOL
CA-210
0.276
±0.002
0.283
±0.002
MEDIUM
CA-210
0.285
±0.002
0.293
±0.002
WARM
CA-210
0.313
±0.002
0.329
±0.002
Item
Min
Typ Max Unit
Remark
White  
49
60
-cd/m -
 100%Window White 
average
Pattern
brightness
- 100IRE(255Gray)
- Picture: Vivid(Medium )
Brightness 
-20
+20
%
- 85IRE(216Gray) 100% 
uniformity
Window White Pattern
- Picture: Vivid(Medium)
6. Test of RS-232C control.
- Press In-Start button of Service Remocon then set the “4.Baud
Rate” to 115200. Then check RS-232C control and 
7. Selection of Country option.
model  (Not  allowed  Korean  model).  It  is  selection  of  Country
about Rating and Time Zone.
(1) Models: All  models  which  PB82C  Chassis  (See  the  first
page.) 
(2) Press “In-Start” button of Service Remocon, then enter the
“Option” Menu with “PIP CH-“ Button 
(3) Select  one  of  these  three  (USA,  CANADA,  MEXICO)
defends on its market using “Vol. +/-“button.
Caution : Don’t  push  The  INSTOP  KEY  after  completing  the
function inspection
Caution : Inspection only PAL M / NTSC
8. GND and ESD Testing
8-1. Prepare GND and ESD Testing.
- Check the connection between set and power cord
8-2. Operate GND and ESD auto-test.
(1) Fully  connected  (Between  set  and  power  cord)  set  enter
the Auto-test sequence.
(2) Connect D-Jack AV jack test equipment.
(3) Turn on Auto-controller(GWS103-4)
(4) Start Auto GND test.
(5) If its result is NG, then notice with buzzer.
(6) If its result is OK, then automatically it turns to ESD Test.
(7) Operate ESD test
(8) If its result is NG, then notice with buzzer.
(9) If  its  result  is  OK,  then  process  next  steps.  Notice  it  with
Good lamp and STOPER Down.
8-3. Check Items.
(1) Test Voltage 
GND: 1.5KV/min at 100mA
Signal: 3KV/min at 100mA
(2) Test time: just 1 second.
(3) Test point
- GND test: Test  between  Power  cord  GND  and  Signal
cable metal GND.
- ESD test: Test  between  Power  cord  GND  and  Live  and
neutral.
(4) Leakage current: Set to 0.5mA(rms)
9. POWER PCB Ass’y Voltage
Adjustment
(Va/Vs Voltage Adjustment)
(1)Test equipment : D.M.M 1EA
(2) Connection Diagram for Measuring : refer to fig.1 
9-1. Adjustment method
(1) Vs adjustment (refer fig.1)
1) Connect + terminal of D.M.M. to Vs pin of P811, connect
-terminal to GND pin of P811
2) After  turning  VR901,  voltage  of  D.M.M  adjustment  as
same  as  Vs  voltage  which  on  label  of  panel  left/top    (
deviation ; ±0.5V)
(2) Va adjustment (refer fig.1)                                               
1) After receiving 100% Full White Pattern, HEAT RUN.
2) Connect + terminal of D.M.M. to Va pin of P811, connect
-terminal to GND pin of P811.
3) After  turning  VR502,voltage  of  D.M.M  adjustment  as
same  as  Va  voltage  which  on  label  of  panel  left/top
(deviation; ±0.5V)
10. Default Service option.
10-1. ADC-Set
.
V
R-Gain adjustment Value (default  128)
V
G-Gain adjustment Value (default  128)
V
B-Gain adjustment Value (default  128)
V
R-Offset adjustment Value (default  128)
V
G-Offset adjustment Value (default  128)
V
B-Offset adjustment Value (default  128)
10-2. White balance. Value.
- 11 -
CENTER (DEFAULT)
Cool
Mid
Warm
R Gain
192
192
192
G Gain
192
192
192
B Gain
192
192
192
R Cut
64 
64
64  
G Cut
64
64
64
B Cut
64
64
64
< fig.1 : 42 inch Power PCB Assy Voltage adjustment >
<XPOWER4 42T3 PSU>
10-3. Temperature Threshold
V
Threshold Down Low
20
V
Threshold Up Low
23
V
Threshold Down High 70
V
Threshold Up High
75
11. USB DOWNLOAD 
(*.epk file download)
V
Put the USB Stick to the USB socket
V
Press Menu key, and move OPTION 
V
Press “FAV” Press 7 times.
V
Select download file (epk file)
V
After download is finished, remove the USB stick.
Press “IN-START” key of ADJ remote control, check the
S/W version.
- 12 -