LG 42PT250-TA (CHASSIS:PA11K) Service Manual ▷ View online
Making
- 6-2
Revision
A16
PDP TV
Symptom
A. Picture Problem
Y Drive B/D Checking method(50R1)
Repair Process-Reference data
A16
▣
Y drive board
※ Check all output pins of scan IC (connector) using DMM.
Input signal connector
Scan IC
※ DMM (Digital Multi-Meter)
2010. 11. 16
Making
- 6-2
Revision
PDP TV
Symptom
A. Picture Problem
(Half picture) X- B/D Checking method(50R1)
Repair Process-Reference data
A18
A18
▣
Half / partly display (or abnormal display)
※ Check connections (TCP - X board, CTRL board - X board)
-. Check Va input voltage.
(P121, P120, P220, P221, P320 : Power connector of the X board)
-. Check cables between CTRL board and X board.
-. Replace the X B/D.
-. Check TCP connection after X B/D replacement.
-. Replace the X B/D.
-. Check TCP connection after X B/D replacement.
▣
Connections between panel and X B/D
-. Right display (Picture 1.) ↔ Check/replace right X B/D
-. Both ends display (Picture 2.) ↔ Check/replace center X B/D
-. Left display (Picture 3.) ↔ Check/replace left X B/D
-. Both ends display (Picture 2.) ↔ Check/replace center X B/D
-. Left display (Picture 3.) ↔ Check/replace left X B/D
Picture 1.
Picture 2.
Picture 3.
Half
display
(abnormal)
Partly
display
(abnormal)
abnormal
abnormal
Va
Va
Va
from CTRL
from CTRL
from CTRL
2010. 11. 16
Making
- 6-2
Revision
PDP TV
Symptom
A. Picture Problem
Defect type cause by PDP Module
Repair Process-Reference data
A19
Symptom picture
defects description
To action
Regular vertical lines
1. Check connection
(CTRL B/D, X B/D)
2. Check CTRL B/D
3. Replace CTRL B/D
Vertical lines or Bar
1. Check connection
(CTRL B/D, X B/D)
2. Check CTRL B/D
3. Replace CTRL B/D
Many irregular vertical lines
1. Check connection
(CTRL B/D, X B/D)
2. Check CTRL B/D
3. Replace CTRL B/D
Horizontal Line or Bar
1. Check connection
(Y-Sus B/D ↔Panel)
2. Check Y-Sus B/D
3. Replace Y-Sus B/D
First of all, Check whether all of cable between board was inserted properly or not.
Next, Check whether there is foreign material on connector.
Next, Check whether there is foreign material on connector.
A19
2010. 11. 16
Making
- 6-2
Revision
PDP TV
Symptom
A. Picture Problem
Connector Type on PDP Module
Repair Process-Reference data
A20
96 Out Put
COF Type
1. Check foreign & Connection status
2. Check bad soldering
2. Check bad soldering
on Chip resistance
▣ Defect symptom
192 Out Put
TCP Type
TCP (Tape Carrier Package) is film
for IC connect with Electrode pattern
(Direct Bonding) on X B/D
(Direct Bonding) on X B/D
FFC Type
Connector to connect between
Electrode PAD Of PANEL and
Y Drive B/D,Z-Sus B/D
Electrode PAD Of PANEL and
Y Drive B/D,Z-Sus B/D
A20
2010. 11. 16