4.4. Wi-Fi Test
Step 1) Turn on TV
Step 2) Select Network Connection option in Network Menu.
Instart  menu  ->  Menu  ->  Network  Setup  (Network 
Setting>Press OK)
Step 3) Select Start Connection button in Network Connection.
Step 4)  If the system finds any AP like blow PIC, it is working 
well.
4.5. HDMI ARC Function Inspection
4.5.1. Test equipment
- Optic Receiver Speaker
- MSHG-600 (SW: 1220 ↑) 
- HDMI Cable (for 1.4 version)
4.5.2. Test method
(1)  Insert  the  HDMI  Cable  to  the  HDMI ARC  port  from  the 
master equipment (HDMI1)
(2) Check the sound from the TV Set
(3)  Check  the  Sound  from  the  Speaker  or  using AV  &  Optic 
TEST program (It’s connected to MSHG-600)
* Remark:  Inspect in Power Only Mode and check SW version 
in a master equipment
4.6. Local Dimming Function Check
Step 1) Turn on TV.
Step 2) Press “TILT” key on the Adj. R/C.
Step 3)  At  the  Local  Dimming  mode,  module  Edge  Backlight 
moving right to left Back light of IOP module moving.
Step 4) Confirm the Local Dimming mode.
Step 5) Press "exit" key.
4.7. Magic Motion Remote control test
(1)  Equipment  :  RF  Remote  control  for  test,  IR-KEY-Code 
Remote control for test
(2)  You  must  confirm  the  battery  power  of  RF-Remote  control 
before test.(recommend that change the battery per every lot)
(3) Sequence (test)
1)  if  you  select  the  "Start(Wheel)"  key  on  the Adjustment 
remote control, you can pairing with the TV SET.
2)  You can check the cursor on the TV Screen, when select 
the "Wheel" key on the Adjustment remote control.
3)  You must remove the pairing with the TV Set by select 
"Mute" key on the Adjustment remote control.
Local Dimming Demo
(Edge LED Model)
- 14 -
5. Check Commercial features
5.1. External SPK Out
5.1.1. Equipment & Condition
▪ Jig (Speaker out JIG) or Oscilloscope
5.1.2. Check the speaker out
1) Connect the External Speaker : check the sound
    Connect oscilloscope, you can see this waveform.
5.2. IR Out and DC Power Outlet (5V/12V) 
(1) Equipment & Condition
▪ Jig (commercial check JIG) 
▪ Special 232C Cable for commercial check Jig
▪ Power only mode
▪  PCB mode (instart menu -> menu -> Configuration Setup 
-> RS232 DC Power Outlet )
(2) Check the power out & IR out - commercial check jig
1)  Connect  each  other  RS232c  port  on  the  Commercial 
Check JIG
2)  Press  RED  Color  Button  on  SVC  Remote-control  in 
power only mode (or PCB mode)
3) Check the LED of jig board
- +5 V / +12 V LED (OK condition: Turn On)
- IR LED (OK condition: blinking) 
(3) Check the power out & IR out - mini jig
1) Connect mini jig on RS232c port
2)  Press  RED  Color  Button  on  SVC  Remote  control  in 
power only mode (or PCB mode)
3) Check the LED of mini jig
(4) Pro:Idiom Check
1) Connect the RF Cable
2) Turn to the Pro:Idiom channel (No. 333)
3) Check the video & sound
** Only displayed at “POWER ONLY” mode
6. Audio
Measurement condition:
(1) RF input: Mono, 1 KHz sine wave signal, 100 % Modulation
(2) CVBS, Component: 1 KHz sine wave signal 0.5 Vrms
Mode info.
Commercial Feature
Name
inch
IR 
Out
DC Power 
Out (5V/ 12V)
Ext 
SPK 
Out
CLOCK Pro:Idiom 
LP860H-ZA 42/47/55
O
O
O
X
O
No.
Item
Min
Typ
Max
Unit
Remark
1.
Audio practical 
max Output, L/R
(Distortion=10% 
max Output)
9
10
12
W
EQ Off
AVL Off
Clear Voice Off
8.10
10.8
Vrms
2.
Speaker (8 Ω
Impedance)
9
10
12
W
- 15 -
7. GND and HI-POT Test
7.1. Tool Option selection
▪  Method:  Press Adj.  key  on  the Adj.  R/C,  then  select Tool 
option. 
7.1. Ship-out mode check (In-stop)
▪ After final inspection, press In-Stop key of the Adj. R/C and 
check that the unit goes to Stand-by mode.
 
7.2 GND and Hi-pot auto-check
7.2.1 Method
(1) GND & Hi-pot auto-check preparation
    -  Check  that  Power  Cord  is  fully  inserted  to  the  SET.  (If 
loose, re-insert)
(2) Perform GND & Hi-pot auto-check
    -  Unit  fully  inserted  Power  cord, Antenna  cable  and A/V 
arrive to the auto-check process. 
    - Connect D-terminal to AV JACK TESTER
    - Auto CONTROLLER(GWS103-4) ON
    - Perform GND TEST
    - If NG, Buzzer will sound to inform the operator.
    - If OK, changeover to I/P check automatically.
      (Remove CORD, A/V form AV JACK BOX)
    - Perform I/P test
    - If NG, Buzzer will sound to inform the operator.
    -  If OK, Good lamp will lit up and the stopper will allow the 
pallet to move on to next process.
7.2.2. Checkpoint
▪ TEST voltage
   - GND: 1.5 KV / min at 100 mA
   - SIGNAL: 3 KV / min at 100 mA
▪ TEST time: 1 second
▪ TEST POINT
   -  GND  TEST  =  POWER  CORD  GND  &  SIGNAL  CABLE 
METAL GND
   - Hi-pot TEST = POWER CORD GND & LIVE & NEUTRAL
▪ LEAKAGE CURRENT: At 0.5 mArms
8. USB S/W Download(Service only)
(1) Put the USB Stick to the USB socket 
(2) Automatically detecting update file in USB Stick
-  If  your  downloaded  program  version  in  USB  Stick  is 
Lower, it didn’t work.
 But  your  downloaded  version  is  Higher,  USB  data  is 
automatically detecting (Download Version High & Power 
only mode, Set is automatically Download)
(3) Show the message “Copying files from memory”
(4) Updating is starting.
(5) Updating Completed, The TV will restart automatically.
(6)  If  your TV  is  turned  on,  check  your  updated  version  and 
Tool option. (explain the Tool option, next stage)
*  If downloading version is more high than your TV have, 
TV  can  lost  all  channel  data.  In  this  case,  you  have  to 
channel recover. if all channel data is cleared, you didn’t 
have a DTV/ATV test on production line.
* After downloading, have to adjust Tool Option again.
(1) Push "IN-START" key in service remote control.
(2) Select "Tool Option 1" and push "OK" key.
(3) Punch in the number. (Each model has their number)
- 16 -
TROUBLESHOOTING GUIDE
1. Power-Up Boot Fail Trouble Shooting guide
2. No OSD Trouble Shooting guide
Check P2401 All
Voltage Level (3.5V, 12V, 24V).
Check P2401 All
Voltage Level (3.5V, 12V, 24V).
Check Q2407 output 
Voltage(12V).
Check IC8700 RESET pin.
Check LVDS Cable.
Check X8701 Clock
10MHz.
Check IC8700 IIC 
Communication status.
Check IR input state of IC8700
13pin.
Re-download NEC Micom
Check LCD Module
Control board
Check power connector and
RL_ON signal OK?
Check power connector and
RL_ON signal OK?
Check Q2407 application circuit 
Or replace Q2407.
Check switch SW8700.
Replace Cable.
Check X8701 application circuit
or Replace X8701.
Check IIC line or replace 
IC8700.
Check IR board.
Replace Power Board.
Replace Power Board.
N
N
N
N
N
N
N
N
Y
Y
Y
Y
Y
Y
Y
Y
N
N