DOWNLOAD LG 39LN54XX / 39LN540V (CHASSIS:LD31B / LD36B) Service Manual ↓ Size: 7.81 MB | Pages: 77 in PDF or view online for FREE

Model
39LN54XX 39LN540V (CHASSIS:LD31B LD36B)
Pages
77
Size
7.81 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD
File
39ln54xx-39ln540v-chassis-ld31b-ld36b.pdf
Date

LG 39LN54XX / 39LN540V (CHASSIS:LD31B / LD36B) Service Manual ▷ View online

- 13 -
* Manual W/B process using adjust Remote control.
▪ After enter Service Mode by pushing "ADJ" key,
▪  Enter  White  Balance  by  pushing  "►"  key  at  "8.  White 
Balance".
* CASE Cool Mode
First  adjust  the  coordinate  far  away  from  the  target 
value(x, y).B.
1) x, y > target
2) x, y < target
3) x >target, y < target
4) x < target, y > target
   -  Every 4 case have to fit y value by adjusting B Gain 
and then fit x value by adjusting R-Gain.
   -  In  this  case,  increasing/decreasing  of  B  Gain  and  R 
Gain can be adjusted.
How to adjust
1) In case G gain more than 172
    Adjust R Gain and B Gain less than 192 
2) if the G gain value be adjusted down to 172
     G  gain  increase  to  172  and  R  gain  /  B  gain  increase 
same as G gain increases.
3)  if R Gain / B Gain is more than 255 , the G gain adjust 
to less than 172.
* CASE Medium / Warm
First  adjust  the  coordinate  far  away  from  the  target 
value(x, y).
1) x, y > target
i) Decrease the R, G. 
2) x, y < target
i) First decrease the B gain, 
ii) Decrease the one of the others.
3) x > target, y < target
i) First decrease B, so make y a little more than the target.
ii) Adjust x value by decreasing the R
4) x < target, y > target
i) First decrease B, so make x a little more than the target.
ii) Adjust x value by decreasing the G
*  After you finished all adjustments, Press "In-start" key and 
compare Tool option and Area option value with its BOM, if 
it  is  correctly  same  then  unplug  the AC  cable.  If  it  is  not 
same, then correct it same with BOM and unplug AC cable.
For correct it to the model's module from factory Jig model.
*  Push  the  "IN  STOP"  key  after  completing  the  function 
inspection. And  Mechanical  Power  Switch  must  be  set 
“ON”.
4.2. 3D function test
(Pattern Generator MSHG-600, MSPG-6100[Support HDMI1.4])
* HDMI mode NO. 872 , pattern No.83
(1)  Please input 3D test pattern like below. 
(2)  When 3D OSD appear automatically , then select OK key.
(3)  Don't wear a 3D Glasses, Check the picture like below.
4.3. IR emitter inspection
(1) Start 3D pattern inspection.
(2)  If IR emitter signal is correctly received to IR receiver, the 
lamp of IR tester turns on.
EZ ADJUST
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Tool Option5
5. Tool Option Commercial
6. Country Group
7. Area Option
8. ADC Calibration
9. White Balance
10. 10 Point WB
11. Test Pattern
12 EDID D/L
13. Sub B/C
14. Ext. Input Adjust
Whit Balance
Color Temp. 
 
R-Gain
G-Gain
B-Gain
R-Cut
G-Cut
B-Cut
Test-Pattern
Backlight
Reset 
      To Set
Cool
172
172
192
64
64
64
ON
100
- 14 -
4.4. MHL Test
(1) Turn on TV
(2) Select HDMI2 mode using input Menu.
(3)  Set  MHL  Zig(M1S0D3617)  using  MHL  input,  output  and 
power cord.
(4) Connect HDMI cable between MHL Zig and HDMI4 port.
Result)  If,  The  LED  light  is  green  and  the  Module  shows 
normal stream → OK, Else → NG
4.5. Outgoing condition Configuration
■  When  pressing  IN-STOP  key  by  SVC  remocon,  Red  LED 
are blinked alternatively. And then automatically turn off.
(Must not AC power OFF during blinking)
5. HI-POT Test
5.1. HI-POT auto-check preparation
-  Check the POWER cable and SIGNAL cable insertion condition
5.2. HI-POT auto-check
(1)  Pallet moves in the station. (POWER CORD / AV CORD is 
tightly inserted)
(2) Connect the AV JACK Tester.
(3) Controller (GWS103-4) on.
(4) HI-POT test (Auto)
- If Test is failed, Buzzer operates.
- If Test is passed, GOOD Lamp on and move to next proc-
ess automatically.
5.3. Checkpoint
(1) Test voltage
- Touchable Metal : 3 KV / min at 100 mA
- SIGNAL : 3KV / min at 100 mA
(2) TEST time: 1 second. (case : mass production )
(3) TEST POINT
- Touchable Metal => LIVE & NEUTRAL : Touchable Metal.
- SIGNAL => LIVE & NEUTRAL : SIGNAL.
6. Model name & Serial number D/L
▪ Press "Power on" key of service remote control.
(Baud rate : 115200 bps)
▪ Connect RS232 Signal Cable to RS-232 Jack.
▪ Write Serial number
▪  Must check the serial number at the Diagnostics of SET UP menu.
  (Refer to below).
6.1. Signal Table
CMD : A0h
LENGTH : 85~94h (1~16 bytes)
ADH : EEPROM Sub Address high (00~1F)
ADL : EEPROM Sub Address low (00~FF)
Data : Write data
CS : CMD + LENGTH + ADH + ADL + Data_1 +...+ Data_n
Delay : 20ms
6.2. Command Set
* Description
FOS Default write : <7mode data> write
Vtotal,  V_Frequency,  Sync_Polarity,  Htotal,  Hstart,  Vstart,  0, 
Phase
Data write : Model Name and Serial Number write in EEPROM,.
6.3. Method & notice
(1) Serial number D/L is using of scan equipment.
(2)  Setting  of  scan  equipment  operated  by  Manufacturing 
Technology Group.
(3)  Serial number D/L must be conformed when it is produced in 
production  line,  because  serial  number  D/L  is  mandatory  by 
D-book 4.0.
CMD
LENGTH
ADH
ADL
DATA_1
. . .
Data_n
CS
DELAY
Adjust mode
CMD(hex)
LENGTH(hex)
Description
EEPROM WRITE
A0h
84h+n
n-bytes Write (n = 1~16)
- 15 -
* Manual Download(Model Name and Serial Number)
If the TV set is downloaded by OTA or Service man, sometimes 
model name or serial number is initialized.(Not always)
There is impossible to download by bar code scan, so It need 
Manual download.
1) Press the "Instart" key of Adjustment remote control.
2) Go to the menu "6.Model Number D/L" like below photo.
3) Input the Factory model name or Serial number like photo.
4)  Check the model name Instart menu. → Factory name displayed. 
ex 32LV3400-ZG)
5)  Check  the  Diagnostics.(DTV  country  only)  →  Buyer  model 
displayed.(ex 32LV3400-ZG)
7. MAC Address & CI+ key download
7.1 MAC Address 
7.1.1 Equipment & Condition
▪ Play file : Serial.exe
▪ MAC Address edit
▪ Input Start / End MAC address 
7.1.2 Download method
(1) Communication Prot connection
Connection  :  PCBA  (USB  Port) 
  USB  to  Serial Adapter 
(UC-232A) 
 RS-232C cable 
 PC(RS-232C port) 
* Caution :  LJ21*  chassis  support  only  UC-232A  driver.  (only 
use this one. ) 
(2) MAC Address & CI+ Key Download
▪  Set CI+ Key path Directory at Start Mac & CI+ Download 
Programme
▪ Com 1,2,3,4 and 115200(Baudrate)
▪ Port connection button click(1)
▪ Push the (2) MAC Address write.
▪ At success Download, check the OK (3)
▪ Start CI+ Key Download, Push the (4)
▪ Check the OK or NG
GP4_LOW
- 16 -
7.2 LAN Inspection
7.2.1. Equipment & Condition
▪ Each other connection to LAN Port of IP Hub and Jig
7.2.2. LAN inspection solution
▪ LAN Port connection with PCB
▪ Network setting at MENU Mode of TV
▪ Setting automatic IP
▪ Setting state confirmation
->  If  automatic  setting  is  finished,  you  confirm  IP  and  MAC 
Address.
7.3. LAN PORT INSPECTION(PING TEST)
Connect SET -> LAN port == PC -> LAN Port
7.3.1. Equipment setting
(1) Play the LAN Port Test PROGRAM.
(2) Input IP set up for an inspection to Test Program.
*IP Number : 12.12.2.2
7.3.2. LAN PORT inspection (PING TEST)
(1) Play the LAN Port Test Program.
(2) Connect each other LAN Port Jack.
(3) Play Test (F9) button and confirm OK Message.
(4) Remove LAN cable.
SET
PC
Page of 77
Display

Click on the first or last page to see other 39LN54XX / 39LN540V (CHASSIS:LD31B / LD36B) service manuals if exist.