LG 37LT560H-CA (CHASSIS:LJ2AC) Service Manual ▷ View online
- 10 -
※
Connecting picture of the measuring instrument
(On Automatic control)
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push Adjustment R/C POWER-ON -> Enter
the mode of White-Balance, the pattern will come out.
●
Auto-control interface and directions
(1) Adjust in the place where the influx of light like floodlight
around is blocked. (Illumination is less than 10ux).
(2) Adhere closely the Color Analyzer ( CA210 ) to the module
less than 10cm distance, keep it with the surface of the
Module and Color Analyzer’s Prove vertically.(80~100°).
(3) Aging time
- After aging start, keep the power on (no suspension of
power supply) and heat-run over 5 minutes.
- Using ‘no signal’ or ‘full white pattern’ or the others, check
the back light on.
● Auto adjustment Map(RS-232C)
RS-232C COMMAND
[ CMD ID DATA ]
Wb 00 00 White Balance Start
Wb 00 ff White Balance End
RS-232C COMMAND
[CMD ID DATA]
MIN
CENTER
(DEFAULT)
MAX
Cool
Mid
Warm
Cool
Mid
Warm
R Gain
jg
Ja
jd
00
172
192
192
192
G Gain
jh
Jb
je
00
172
192
192
192
B Gain
ji
Jc
jf
00
192
192
172
192
R Cut
64
64
64
128
G Cut
64
64
64
128
B Cut
64
64
64
128
** Caution **
Color Temperature : COOL, Medium, Warm.
One of R Gain/G Gain/ B Gain should be kept on 0xC0, and
adjust other two lower than C0.
(when R/G/B Gain are all C0, it is the FULL Dynamic Range of
Module)
*Manual W/B process using adjusts Remote control.
■After enter Service Mode by pushing “ADJ” key,
■Enter White Balance by pushing “►” key at “7. White Balance”.
※
After You finish all adjustments, Press “In-start” button and
compare Tool option and Area option value with its BOM, if it is
correctly same then unplug the AC cable.
If it is not same, then correct it same with BOM and unplug AC
cable. For correct it to the model’s module from factory JIG
model.
※
Push The “IN STOP KEY” after completing the function
inspection. And Mechanical Power Switch must be set “ON”.
- 11 -
4.2. DDC EDID Write (RGB 128Byte)
■ Connect D-sub Signal Cable to D-Sub Jack.
■ Write EDID DATA to EEPROM (24C02) by using DDC2B
protocol.
■ Check whether written EDID data is correct or not.
* For SVC main Ass’y, EDID have to be downloaded to Insert
Process in advance.
4.3. DDC EDID Write (HDMI 256Byte)
■ Connect HDMI Signal Cable to HDMI Jack.
■ Write EDID DATA to EEPROM(24C02) by using DDC2B
protocol.
■ Check whether written EDID data is correct or not.
* For SVC main Ass’y, EDID have to be downloaded to Insert
Process in advance.
4.4. EDID DATA
1) All Data : HEXA Value
2) Changeable Data :
*: Serial No : Controlled / Data:01
**: Month : Controlled / Data:00
***:Year : Controlled
****:Check sum
- Auto Download
■ After enter Service Mode by pushing “ADJ” key,
■ Enter EDID D/L mode.
■ Enter “START” by pushing “OK” key.
※
Edid data and Model option download (RS232C)
NO
Item
CMD 1 CMD 2
Data 0
Enter
download
MODE
Download
‘Mode In’
A
A
0
0
When transfer
the ‘Mode In’,
Carry the com-
mand
Edid data
and Model
option
download
Download
A
E
00
10
Automatically
download
(The use of a
internal Data)
※
Caution
* Use the proper signal cable for EDID Download
- Analog EDID : Pin3 exists
- Digital EDID : Pin3 exists
=> Caution
- Never connect HDMI & D-sub Cable at the same time.
- Use the proper cables below for EDID Writing.
- Download HDMI1, HDMI2 separately because HDMI1 is
different from HDMI2.
For Analog EDID
For HDMI EDID
D-sub to D-sub
DVI-D to HDMI or HDMI to HDMI
No.
Item
Condition
Hex Data
1
Manufacturer ID
GSM
1E6D
2
Version
Digital : 1
01
3
Revision
Digital : 3
03
●
EDID DATA
(1) HD EDID Data
CheckSum
Physical Address (0x9E)
HDMI 1
A4/5B
10
HDMI 2
A4/4B
20
- 12 -
(2) FHD EDID Data(Deep Color support)
CheckSum
Physical Address (0x9E)
HDMI 1
43/DE
10
HDMI 2
43/CE
20
HDMI 3
43/BE
30
- HDMI
-RGB
(3) FHD EDID Data(Deep Color not support)
CheckSum
Physical Address (0x9E)
HDMI 1
43/25
10
HDMI 2
43/15
20
HDMI 3
43/05
30
- HDMI
-RGB
- Model List
HD(LED)
FHD(LED)
26LT360C-SA
37LT560H-SA
32LT360C-SA
42LT360C-SA
32LT560H-SA
42LT560H-SA
- 13 -
4.5. Outgoing condition Configuration
■ When pressing IN-STOP key by SVC remocon, Red LED
are blinked alternatively. And then automatically turn off.
(Must not AC power OFF during blinking)
4.6 GND & Hi-pot test
4.6.1. GND & HI-POT auto-check preparation
(1) Check the POWER CABLE and SIGNAL CABE insertion
condition
4.6.2. GND & HI-POT auto-check
(1) Pallet moves in the station. (POWER CORD / AV CORD is
tightly inserted)
(2) Connect the AV JACK Tester.
(3) Controller (GWS103-4) on.
(4) GND Test (Auto)
- If Test is failed, Buzzer operates.
- If Test is passed, execute next process (Hi-pot test).
(Remove A/V CORD from A/V JACK BOX)
(5) HI-POT test (Auto)
- If Test is failed, Buzzer operates.
- If Test is passed, GOOD Lamp on and move to next
process automatically.
4.6.3. Checkpoint
(1) Test voltage
- GND: 1.5KV/min at 100mA
- SIGNAL: 3KV/min at 100mA
(2) TEST time: 1 second
(3) TEST POINT
- GND Test = POWER CORD GND and SIGNAL CABLE
GND.
- Hi-pot Test = POWER CORD GND and LIVE & NEUTRAL.
(4) LEAKAGE CURRENT: At 0.5mArms
5. Local Dimming Function Check
Step1) Turn on TV.
Step2) Press “P-only” key, enter to power only mode and escape
the “P-only” Mode by pressing “Exit” key
Step3) Press “Tilt” key, entrance to Local Dimming mode.
Step4) At the Local Dimming mode, module Edge Backlight moving
Top to bottom Back light of module moving
Step5) confirm the Local Dimming mode
Step6) Press “Exit” key
,