DOWNLOAD LG 26LQ630H (CHASSIS:LA1EY) Service Manual ↓ Size: 6.25 MB | Pages: 41 in PDF or view online for FREE

Model
26LQ630H (CHASSIS:LA1EY)
Pages
41
Size
6.25 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD
File
26lq630h-chassis-la1ey.pdf
Date

LG 26LQ630H (CHASSIS:LA1EY) Service Manual ▷ View online

- 9 -
5.3. White Balance Adjustment
5.3.1. Overview
5.3.1.1. W/B adj. Objective & How-it-works
(1) Objective: To reduce each Panel’s W/B deviation
(2)  How-it-works:  When  R/G/B  gain  in  the  OSD  is  at  192,  it 
means the panel is at its Full Dynamic Range. In order to 
prevent saturation of Full Dynamic range and data, one of 
R/G/B is fixed at 192, and the other two is lowered to find 
the desired value.
(3) Adj. condition: normal temperature
- Surrounding Temperature: 25±5 ºC
- Warm-up time: About 5 Min
- Surrounding Humidity: 20% ~ 80%
5.3.2. Equipment
(1)  Color Analyzer: CA-210 (NCG: CH 9 / WCG: CH12 / LED: 
CH14)
(2)  Adj.  Computer(During  auto  adj.,  RS-232C  protocol  is 
needed)
(3) Adjust Remocon
(4)  Video  Signal  Generator  MSPG-925F  720p/204-Gray 
(Model:217, Pattern:49)
      → Only when internal pattern is not available
     ※  Color  Analyzer  Matrix  should  be  calibrated  using 
CS-1000
5.3.3. Equipment connection
5.3.4. Adjustment Command (Protocol)
(1) RS-232C Command used during auto-adj
RS-232C COMMAND
Explanation
CMD
DATA
ID
Wb
00
00
Begin White Balance adj.
Wb
00
ff
End White Balance adj. 
(internal pattern disappears )
Ex) wb 00 00   ->  Begin white balance auto-adj.
      wb 00 10   ->  Gain adj.
      ja 00 ff   ->  Adj. data
      jb 00 c0
      ...
      ...
wb 00 1f   -> Gain adj. complete
*(wb 00 20(start), wb 00 2f(endc)) -> Off-set adj.
wb 00 ff   ->End white balance auto adj.
(2) Adjustment Map
     Applied Model : 26LQ630H -UA,
Adj. item
Command
(lower case ASCII)
Data Range
(Hex.)
Default
(Decimal)
CMD1
CMD2
MIN
MAX
Cool
R Gain
j
g
00
C0
TBD
G Gain
j
h
00
C0
TBD
B Gain
j
i
00
C0
TBD
R Cut
TBD
G Cut
TBD
B Cut
TBD
Medium
R Gain
j
a
00
C0
TBD
G Gain
j
b
00
C0
TBD
B Gain
j
c
00
C0
TBD
R Cut
TBD
G Cut
TBD
B Cut
TBD
Warm
R Gain
j
d
00
C0
TBD
G Gain
j
e
00
C0
TBD
B Gain
j
f
00
C0
TBD
R Cut
TBD
G Cut
TBD
Color Analyzer 
Computer 
Pattern Generator 
 
Signal Source 
Probe 
RS-232C 
RS-232C 
RS-232C 
If TV internal pattern is used, not needed 
- 10 -
5.3.5. Adjustment method
5.3.5.1 Auto adj. method
(1) Set TV in adj. mode using POWER ONLY (P-ONLY) key
(2)  Zero  calibrate  probe  then  place  it  on  the  center  of  the 
Display
(3) Connect Cable(RS-232C)
(4) Select mode in adj. Program and begin adj.
(5)  When adj. is completed (OK Sing), check adj. status of pre 
mode (Cool, Medium, Warm)
(6) Remove probe and RS-232C cable to complete adj.
▪  W/B Adj.  must  begin  as  start  command  “wb  00  00”  ,  and 
finish as end command “wb 00 ff”, and Adj. offset if need
5.3.5.2. Manual adj. method
(1) Set TV in Adj. mode using POWER ON
(2)  Zero Calibrate the probe of Color Analyzer, then place it on 
the center of LCD module within 10cm of the surface..
(3)  Press ADJ  key  ->  EZ  adjust  using  adj.  R/C  ->  6.  White-
Balance then press the cursor to the right (KEY►).
      (When  KEY(►)  is  pressed  204  Gray(80IRE)  internal 
pattern will be displayed)
(4)  One of R Gain / G Gain / B Gain should be fixed at 192, 
and the rest will be lowered to meet the desired value.
(5)  Adj. is performed in COOL, MEDIUM, WARM 3 modes of 
color temperature.
▪  If  internal  pattern  is  not  available,  use  RF  input.  In  EZ Adj. 
menu 6.White Balance, you can select one of 2 Test-pattern: 
ON,  OFF.  Default  is  inner(ON).  By  selecting  OFF,  you  can 
adjust using RF signal in 204 Gray pattern.
▪ Adj. condition and cautionary items
(1) Lighting condition in surrounding area
      Surrounding lighting should be lower 10 lux. Try to isolate 
adj. area into dark surrounding.
(2)  Probe location : Color Analyzer (CA-210) probe should be 
within 10cm and perpendicular of the module surface (80°~ 
100°)
(3) Aging time
-  After  Aging  Start,  Keep  the  Power  ON  status  during  5 
Minutes.
-  In  case  of  LCD,  Back-light  on  should  be  checked  using  no 
signal or Full-white pattern.
5.3.6.  Reference (White Balance Adj. coordinate and 
color temperature)
■ W/B Equipment condition
CA210 :  CCFL/EEFL -> Ch.9 Test Signal : Inner pattern (80IRE)
               LED -> Ch.14 Test Signal : Inner pattern (80IRE)
■  Above 5 minutes H/run in the inner pattern. (“power on” key 
of adjust remote control)
(1) 22LQ630H-UA
Mode
Coordinate
Temp
uv
Remark
X
Y
Cool
0.285 (±0.002) 0.293 (±0.002) 9,300 0.0000  <Test Signal>
Inner Pattern
(204 Gray, 80IRE)
Medium 0.295 (±0.002) 0.305 (±0.002) 8,000 0.0000 
Warm
0.313 (±0.002) 0.329 (±0.002) 6,500 0.0000 
(2) 26/32LQ630H-UA
Mode
Coordinate
Temp
uv
Remark
X
Y
Cool
0.269 (±0.002) 0.273 (±0.002) 13,000 0.0000  <Test Signal>
Inner Pattern
(204 Gray, 80IRE)
Medium 0.285 (±0.002) 0.293 (±0.002)
9,300 0.0000 
Warm
0.313 (±0.002) 0.329 (±0.002)
6,500 0.0000 
■  In case of LGD Edge LED module, the color coordinates is 
changing by aging, so you have to use the below table. 
   EDGE LED (26/32LQ630H-UA) – LGD Only
5.4 HDCP 
     (High-Bandwidth  Digital  Contents 
Protection) SETTING
- 11 -
5.5. Option selection per country
5.5.1. Overview
America due to rating
(2)  Applied model: LA2AC Chassis is applied in USA 
5.5.2. Method
(1)  Press ADJ  key  on  the Adj.  R/C,  and  then  select  Country 
Group Menu
(2)  Depending  on  destination,  select  KR  or  US,  then  on  the 
lower Country option, select US, CA, MX.
     Selection is done using +, - KEY
5.5.3. Tool Option inspection
▪ Press Adj. key on the Adj. R/C, then select Tool option.
Model
Module Tool 1 Tool 2 Tool 3 Tool 4 Tool 5 COM-
MERCIAL 
OPTION
22LQ630H-UA
8196
10250 53289
2564
256
114
1034
26LQ630H-UA
12288 10251 53291
2564
268
114
1034
32LQ630H-UA
16384 10251 53291
2564
256
114
1035
5.7. Ship-out mode check (In-stop)
▪  After final inspection, press In-Stop key of the Adj. R/C and 
check that the unit goes to Stand-by mode
6. GND and HI-POT Test
6.1. GND & HI-POT auto-check preparation
(1)  Check  the  POWER  CABLE  and  SIGNAL  CABE  insertion 
condition
6.2. GND & HI-POT auto-check
(1)  Pallet moves in the station. (POWER CORD / AV CORD is 
tightly inserted)
(2) Connect the AV JACK Tester.
(3) Controller (GWS103-4) on.
(4) GND Test (Auto) 
- If Test is failed, Buzzer operates.
- If Test is passed, execute next process (Hi-pot test).       
  (Remove A/V CORD from A/V JACK BOX) 
(5) HI-POT test (Auto)
 - If Test is failed, Buzzer operates.
 -  If Test is passed, GOOD Lamp on and move to next process 
automatically.
6.3. Checkpoint
(1) Test voltage
- GND: 1.5KV/min at 100mA
- SIGNAL: 3KV/min at 100mA
(2) TEST time: 1 second
(3) TEST POINT
- GND Test = POWER CORD GND and SIGNAL CABLE GND.
- Hi-pot Test = POWER CORD GND and LIVE & NEUTRAL.
(4) LEAKAGE CURRENT: At 0.5mArms
7. AUDIO
No
Item
Min
Typ
Max
Unit
1. Audio practi-
cal max 
Output, L/R
(Distor-
tion=10% 
max Output)
6.3
7.0
8.4
W
Measurement 
condition
EQ Off
AVL Off
Clear Voice Off
7.09
7.48
8.19
Vrms
2. Speaker 
(8Ω Imped-
ance)
5.0
15.0
W
Measurement 
condition
EQ On
AVL On
Clear Voice On
● Measurement condition:
(1) RF input: Mono, 1KHz sine wave signal, 100% Modulation
(2) CVBS, Component: 1KHz sine wave signal 0.4Vrms
(3) RGB PC: 1KHz sine wave signal 0.7Vrms
8. USB Boot file Download 
    (Option, Service only)
(1)  Execute  ISP  program  “Mstar  ISP  Utility”  and  then  click 
“Config” tab.
(2)  Set as below, and then click “Auto Detect” and check “OK” 
message.  If  “Error”  is  displayed,  Check  connection 
between computer, jig, and set.
(3)  Click  “Read”  tab,  and  then  load  download  file  (XXXX.bin) 
by clicking “Read”
(4)  Click  “Connect”  tab.    If  “Can’t  ”  is  displayed,  Check 
connection between computer, jig, and set
(5) Click “Auto” tab and set as below
(6) Click “Run”.
(7) After downloading, check “OK” message
(1) 
filexxx.bin
(2) 
(3) 
Please Check the Speed
To use speed between
from 200KHz to 400KHz
- 12 -
9. USB S/W Download 
    (optional, Service only)
(1) Put the USB Stick to the USB socket 
(2) Automatically detecting update file in USB Stick
  -  If  your  downloaded  program  version  in  USB  Stick  is  lower 
than  that  of TV  set,  it  didn’t  work.  Otherwise  USB  data  is 
automatically detected.
(3) Show the message “Copying files from memory”
(5) Updating Completed, The TV will restart automatically
(6)  If  your TV  is  turned  on,  check  your  updated  version  and 
Tool option. 
*  If downloading version is more high than your TV have, TV 
can lost all channel data. In this case, you have to channel 
recover. If all channel data is cleared, you didn’t have a DTV/
ATV test on production line.
* After downloading, TOOL OPTION setting is needed again.
(1) Push "IN-START" key in service remote controller.
(2) Select "Tool Option 1" and Push “OK” button.
(3) Punch in the number. (Each model has their number.)
10. LAN  Main board Check
10.1. Overview 
▪ It is LNET RF modem  & FTG card
10.2. Equipment 
(1) b_LAN Checker:  UTC-1000 (with Cable accessory)
(2) Computer(for test result monitoring)
(3) Connection JIG
10.3. Equipment connection map & b_LAN Check 
(4) Updating is staring.
Page of 41
Display