4. Main PCB check process
* APC - After Manual-Insult, executing APC
4.1. Software download
1) Execute ISP program “Mstar ISP Utility” and then click
“Config” tab.
2) Set as below, and then click “Auto Detect” and check “OK”
message. If display “Error”, Check connect computer, jig,
and set.
and set.
3) Click “Connect” tab. If display “Can’t”, Check connect
computer, jig, and set.
4) Click “Read” tab, and then load download file(XXXX.bin) by
clicking “Read”.
5) Click “Auto” tab and set as below
6) click “Run”.
7) After downloading, check “OK” message.
6) click “Run”.
7) After downloading, check “OK” message.
4.2. USB DOWNLOAD
1) Put the USB Stick to the USB socket
2) Automatically detecting update file in USB Stick
- If your downloaded program version in USB Stick is Low,
it’s not work. But your downloaded version is High, USB
data is automatically detecting
data is automatically detecting
3) Show the message “Copying files from memory”
4) Updating is staring.
(1)
(3)
(2)
OK
Please Check Speed :
To us speed between from 200 KHz
to 400 KHz
To us speed between from 200 KHz
to 400 KHz
(4)
filexxx.bin
(5)
(7) ........ OK
(6)
filexxx.bin
USB PORT
- 10 -
5) Finishing the version updating, you have to put out USB
stick and “AC Power” off
6) After putting “AC Power” on and check updated version on
your TV
4.3. ADC Process
4.3.1. PC input ADC
(1) Auto RGB Gain/Offset Adjustment
1) Convert to PC in Input-source
I
2
C COMMAND:0xF4(SELECT INPUT) 0x00 0x60(RGB)
cf. 0x10(TV), 0x20(AV), 0x40(COMPONENT),
0x60(RGB), 0x90(HDMI)
2) Signal equipment displays
Output Voltage : 700 mVp-p
Impress Resolution XGA (1024 x 768 @ 60Hz)
Impress Resolution XGA (1024 x 768 @ 60Hz)
Model : 60 in Pattern Generator
Pattern : 29 in Pattern Generator (MSPG-925 Series)
[gray pattern that left & right is black and center is
white signal (Refer below picture)].
Pattern : 29 in Pattern Generator (MSPG-925 Series)
[gray pattern that left & right is black and center is
white signal (Refer below picture)].
3) Adjust by commanding AUTO_COLOR _ADJUST
(0xF1) 0x00 0x02 instruction.
(2) Confirmation
1) We confirm whether “0xB6” address of EEPROM
“0xA2” is “0xAA” or not.
2) If “0xB6(RGB)” address of EEPROM “0xB2” isn’t
“0xAA”, we adjust once more.
3) We can confirm the ADC values from “0xB0~0xB5
(RGB)” addresses in a page “0xA2”
* Manual ADC process using Service Remote control. After
enter Service Mode by pushing “ADJ” key, execute “Auto-
adjust” by pushing “
adjust” by pushing “
G
” key at “0. ADC CALIBRATION”.
4.3.2. COMPONENT input ADC
(1) Component Gain/Offset Adjustment
1) Convert to Component in Input-source
I
2
C command : 0xF4(Select input) 0x00 0x40(Component)
cf. 0x10(TV), 0x20(AV), 0x40(COMPONENT),
0x60(RGB), 0x90(HDMI)
2) Signal equipment displays
Impress Resolution 480i
MODEL : 209 in Pattern Generator(480i Mode)
PATTERN : 08 in Pattern Generator(MSPG-925
Series)
MODEL : 209 in Pattern Generator(480i Mode)
PATTERN : 08 in Pattern Generator(MSPG-925
Series)
3) Adjust by commanding AUTO_COLOR_ADJUST (0xF1)
0x00 0x02 instruction.
4) Signal equipment display
- Impress Resolution : 1080i
- MODEL: 223
- MODEL: 223
in Pattern Generator(1080i Mode)
- PATTERN: 08 in Pattern generator(MAPG-925
series)
series)
5) Adjust by commanding AUTO_COLOR ADJUST(0xF1)
0x00 0x02 instruction.
* Manual ADC process using Service Remote control. After
enter Service Mode by pushing “ADJ” key, execute “Auto-
adjust” by pushing “
adjust” by pushing “
G
” key at “0. ADC CALIBRATION”.
(2) Confirmation
1) We confirm whether “0xBF(480i)/0xC8(1080i)” address
of EEPROM “0xA2” is “0xAA” or not.
2) If “0xBF(480i)/0xC8(1080i)” address of EEPROM “0xA2”
isn’t “0xAA”, we adjust once more.
3)
We can confirm the ADC values from
“0xB9~0xBE(480i)/ 0xC2~(1080i)” addresses in a page
“0xA2”.
“0xB9~0xBE(480i)/ 0xC2~(1080i)” addresses in a page
“0xA2”.
* Manual ADC Confirmation using Service Remocon. After
enter Service Mode by pushing “INSTART” key.
<Adjustment pattern (PC)>
EZ ADJUST
1. ADC ADJUST
2. SUB B/C ADJUST
3. W/B ADJUST
4. WHITE PATTERN
2. SUB B/C ADJUST
3. W/B ADJUST
4. WHITE PATTERN
: OFF
5. 2HOUR OFF
: ON
6. OAD
7. UART DOWNLOAD
8. FACTORY MODE
7. UART DOWNLOAD
8. FACTORY MODE
: ON
9. DEBUG MODE
: OFF
10. TVLINK-COMM.ADJUST
0. ADC CALIBRATION
: RGB
<Adjustment pattern (COMPONENT)>
EZ ADJUST
1. ADC ADJUST
2. SUB B/C ADJUST
3. W/B ADJUST
4. WHITE PATTERN
2. SUB B/C ADJUST
3. W/B ADJUST
4. WHITE PATTERN
: OFF
5. 2HOUR OFF
: ON
6. OAD
7. UART DOWNLOAD
8. FACTORY MODE
7. UART DOWNLOAD
8. FACTORY MODE
: ON
9. DEBUG MODE
: OFF
10. TVLINK-COMM.ADJUST
0. ADC CALIBRATION
: COMPONENT
- 11 -
4.4. Function Check
4.4.1. Check display and sound
- Check Input and Signal items. (cf. work instructions)
1) TV
2) AV (CVBS/ S-Video)
3) COMPONENT (480i)
4) RGB (PC : 1024 x 768 @ 60hz)
5) HDMI
6) PC Audio In and H/P Out
* Display and Sound check is executed by Remote control.
2) AV (CVBS/ S-Video)
3) COMPONENT (480i)
4) RGB (PC : 1024 x 768 @ 60hz)
5) HDMI
6) PC Audio In and H/P Out
* Display and Sound check is executed by Remote control.
5. Total Assembly line process
5.1. Adjustment Preparation
1) W/B Equipment condition
CA210 : CH 9, Test signal: Inner pattern (85IRE)
2) Above 5 minutes H/run in the inner pattern. (“power on” key
of adjust remote control)
3) 15 Pin D-Sub Jack is connected to the AUTO W/B
EQUIPMENT.
4) Adjust Process will start by execute I2C Command (Inner
pattern (0xF3, 0xFF)).
* Manual ADC process using Service Remo-con. After enter
Service Mode by pushing “ADJ” key, enter “W/B ADJUST” by
pushing “
pushing “
G
” key at “ 3. W/B ADJUST”. (CA-210, CH-9)
* Adjust “R/G/B - GAIN” by pushing “
F
”, “
G
” key at “Cool”
* Adjust “R/G/B - GAIN” by pushing “
F
”, “
G
” key at “Medium”
* Adjust “R/G/B - GAIN” by pushing “
F
”, “
G
” key at “Warm”
5.2. DDC EDID WRITE
1) Connect D-sub Signal Cable to D-Sub Jack.
2) Connect HDMI Signal Cable to HDMI Jack.
3) Write EDID DATA to EEPROM (24C02) by using DDC2B
2) Connect HDMI Signal Cable to HDMI Jack.
3) Write EDID DATA to EEPROM (24C02) by using DDC2B
protocol.
4) Check whether written EDID data is correct or not. (Refer to
Product spec).
5) Remark
A week manufacture in address 0x10 can be changed. And
thus Checksum (Address: 0x7F) can be also changed.
thus Checksum (Address: 0x7F) can be also changed.
5.2.1. EDID DATA
(1) DIGITAL DATA 256Byte
- Remark: A week manufacture in address 0x10 can be
changed. And thus Checksum (Address: 0x7F) can be
also changed.
also changed.
EZ ADJUST
0. ADC CALIBRATION
0. ADC CALIBRATION
: RGB
1. ADC ADJUST
2. SUB B/C ADJUST
2. SUB B/C ADJUST
4. WHITE PATTERN
: OFF
5. 2HOUR OFF
: ON
6. OAD
7. UART DOWNLOAD
8. FACTORY MOD
7. UART DOWNLOAD
8. FACTORY MOD
: ON
9. DEBUG MODE
: OFF
10. TVLINK-COMM.ADJUST
3. W/B ADJUST
Color Temperature
Cool
11,000
K
X=0.276 ± 0.003
<Test Signal>
Y=0.283 ± 0.003
Inner pattern
Medium
9,300
K
X=0.285 ± 0.003
(216gray, 85IRE)
Y=0.293 ± 0.003
Warm
6,500
K
X=0.313 ± 0.003
Y=0.329 ± 0.003
W/B ADJUST
0. MODE : RGB
1. WHITE PATTERN : White
2. TEMPERATURE : Cool
0. MODE : RGB
1. WHITE PATTERN : White
2. TEMPERATURE : Cool
4. G - GAIN : 172
5. B - GAIN : 192
6. R – OFFSET : 128
7. G – OFFSET : 128
8. B – OFFSET : 128
9. RESET
5. B - GAIN : 192
6. R – OFFSET : 128
7. G – OFFSET : 128
8. B – OFFSET : 128
9. RESET
3. R - GAIN : 172
MODEL : 32LG30/AUO_32LG3DC
S/W VER : 1.33.0/ 0.0024
UTT : 1
ADC CAL.
UTT : 1
ADC CAL.
RGB : OK
YPbPr(SD) : OK
YPbPr(HD) : OK
YPbPr(SD) : OK
YPbPr(HD) : OK
1. POWER OFF HISTORY
2. SS CONROL
3. BAUD RATE
2. SS CONROL
3. BAUD RATE
9600
4. AUDIO EQ
ON
5. CHANNEL MUTE ON
6.DTV SNR
6.DTV SNR
0. AREA OPTION
: USA
- 12 -
1) All Data : HEXA Value
2) Changeable Data :
*: Serial No : Controlled / Data:01
**: Month : Controlled / Data:00
***:Year : Controlled
****:Check sum
**: Month : Controlled / Data:00
***:Year : Controlled
****:Check sum
5.3. HDCP setting
(High-Bandwidth Digital Contents Protection)
1) Connect D-sub Signal Cable to D-Sub Jack.
2) Input HDCP key with HDCP-key- in-program.
3) HDCP Key value is stored on EEPROM(AT24C512) which
2) Input HDCP key with HDCP-key- in-program.
3) HDCP Key value is stored on EEPROM(AT24C512) which
is 80~A1 addresses of 0xA0~0xA2 page
4) Write data by 64bytes.
5) AC off/ on and on HDCP button of MSPG925 and confirm
5) AC off/ on and on HDCP button of MSPG925 and confirm
whether picture is displayed or not of using MSPG925
6) HDCP Key value is different among the sets.
5.4. Outgoing condition Configuration
1) After all function test., press IN-STOP Key by SVC Remote
controller. And Make Ship Condition.
2) When pressing IN-STOP key by SVC remocon, Red LED
are blinked alternatively. And then turn off automatically.
(Must not AC power OFF during blinking)
(Must not AC power OFF during blinking)
1) Test Voltage
- GND: 1.5KV/min at 100mA
- SIGNAL: 3KV/min at 100mA
- SIGNAL: 3KV/min at 100mA
2) Test Point
- GND Test = between power cord GND and Signal cable
metal GND
AC input Live.
3) leakage current: 0.5mArms (but, 32LG3DCH as hospital TV
limited by 0.1mArms.)
Click on the first or last page to see other 22LG3DDH (CHASSIS:LA96E) service manuals if exist.