DOWNLOAD LG GR-T692DVQ Service Manual ↓ Size: 1.39 MB | Pages: 31 in PDF or view online for FREE

Model
GR-T692DVQ
Pages
31
Size
1.39 MB
Type
PDF
Document
Service Manual
Brand
Device
Refrigerator
File
gr-t692dvq.zip
Date

LG GR-T692DVQ Service Manual ▷ View online

7-1-2 QUICK COOLING
1. This feature is to shorten the cooling time of the refrigerator by keeping the comp fan running for a while.  When the Quick
Cooling button is pushed, the Quick Cooling LED turns on in order and the comp keeps on running.  In 2 hours, the Quick
Cooling mode will be cleared.
2. When the Defrosting mode starts while in the Quick Cooling mode, defrosting is performed.  After that, the Quick Cooling
mode resumes for the remaining time.
3. When the Quick Cooling button is pushed while in the Defrosting mode, the Quick Cooling mode starts in 7 minutes after
the completion of the defrosting even though the Quick Cooling LED turns on.
4. If a power failure occurs while in the Quick Cooling mode, the Quick Cooling mode will be cancelled when the power is
restored.
5. If the Quick Cooling mode is selected when it has not passed 7 minutes since the comp stopped, the comp will start
running after the remaining time elapses.
7-1-3 OPERATION OF FROM THE FRONT AND THE REAR LED
1. For 2 minutes while the door of the freezer or the refrigerator is open or after it is
closed, the LED turns on in the order of       
and then the all LEDs are kept on.
2. While the LED turns on as described above, the sensor detects the location of the
food and so on.
7-1-4 ALARM FOR OPEN DOOR
1. This feature is to alarm by the buzzer when the door of the freezer or the refrigerator is not closed in 1 minute after it is
opened.
2. In 1 minute after the door is opened, the buzzer sounds three times at the interval of 0.5 second.  After that, every 30
seconds, the buzzer sounds three times with 0.5 sec ON/OFF.
3. The alarming is cancelled when the door of the freezer or the refrigerator is closed while the buzzer sounds.
7-1-5 BUZZER SOUND
1. When the button on the front Display is pushed, “ring-” sound is produced and it works as follows.
- 17 -
FREEZER OR
REFRIGERATOR
DOOR
BUZZER
CLOSE
OPEN
CLOSE
OPEN
CLOSE
three
times
three
times
three
times
three
times
within
1 minute
1 minute
30
seconds
30
seconds
(EX.)
A
B
C
D
E
F
G
H
A
DOOR COOLING
B
F
E
D
H
C
G
A
7-1-6 DEFROSTING
1. The defrosting is performed each time when the total running time of the compressor reaches 7 hours.
2. After the power is turned on (or restored after a power failure), the defrosting starts when the total running time of the
compressor reaches 4 hours.
3. When the temperature of the defrosting sensor reaches 13 °C or above, the defrosting stops.  If the temperature does not
reach 13 °C in 2 hours after the defrosting starts, the defrosting error code is displayed. 
(Refer to 1-8. Error Diagnostic Mode.)
4. With the defective defrosting sensor (cut or short-circuited wire), the defrosting will not be performed.
7-1-7 SEQUENTIAL OPERATION OF ELECTRIC COMPONENTS
The electric components, such as the comp, defrosting heater, and cooling fan, start sequentially to avoid the noise and
damage to the part, which may result from the simultaneous start of various components on turning the power on or after
the completion of a test.
Condition of Operation
Operating Sequence
If the temp of the defrosting 
sensor is 13 °C or above
(For the initial use after the 
purchase or grounding)
If the temp of the defrosting 
sensor is below 13 °C
(After a power failure or SVC)
When returned from the Test mode
- 18 -
POWER
in 0.5 sec
COMP & COOLING FAN
ON
ON
ALL LOADS
in 7 min
COMP & COOLING FAN
OFF
ON
POWER
in 0.5 sec
DEFROSTING
in 10 sec
DEFROSTING
ON
HEATER ON
HEATER OFF
in 0.5 sec
COMP & COOLING FAN 
ON
When the po
wer is turned on
7-1-8 ERROR DIAGNOSTIC MODE
1. The error diagnostic mode allows the SVC when a fault that may affect the performance of the product occurs while
operating the product.
2. Even if the function control button is pushed when an error occurs, the function will not be performed. However, the
recognition tone (beep~) sounds.
3. When the error is cleared while the error code is displayed due to a fault, the appliance returns to the normal condition
(Reset).
4. The error code is displayed by the refrigerator temp indication LED on the display of the refrigerator while the remaining
LEDs are off.
- 19 -
R4 R3 R2 R1
DOOR COOLING
REF.TEMP
REF.TEMP
SUPER COOL
SUPER COOL
Max
Min
▼ 
FOR R-B52DZ/R-B55DZ
NO
Error
Error Code Display
Cause
State of Operation with Error
R1    R2    R3    R4
Comp / Cooling fan
Defrosting heater
: ON
: OFF
: NORMAL
1.
2.
3.
4.
5.
Faulty freezer (F) sensor 
(on the ceiling of the freezer)
Faulty refrigerator(R) sensor 
(on the ceiling of the
refrigerator)
Faulty defrosting sensor
Faulty intake air
temperature sensor 
(in the main PCB)
Defrosting failure
Cut or short-circuited wire of
freezer sensor
Cut or short-circuited wire of
refrigerator sensor
Cut or short-circuited wire of
defrosting sensor
Cut or short-circuited wire of
intake air temperature sensor
Cut or disconnected wire of
defrosting heater or temperature
fuse(indicated at least 4 hours
later after the error occurs)
v
15 min ON/
15 min OFF
v
v
v
v
v
No defrosting
v
v
7-1-9 TEST MODE
1. The test mode allows checking the PCB and the function of the product as well as finding out the defective part in case of
an error.
2. The test button is on the main PCB of the refrigerator (Test S/W).  The test mode will be cleared in 2 hours regardless of
the type of the test mode and then reset.
3. While in the test mode, the function control button is not recognized though the recognition tone (beep~) sounds.
4. After exiting the test mode, be sure reset by unplugging and then plugging in the appliance.
5. If an error, such as a sensor failure, is detected while in the test mode, the test mode is cleared and the error code is
displayed.
6. While an error code is displayed, the test mode will not be activated even if the test button is pushed.
Mode
Manipulation
Contents
Remark
TEST 1
Push the test button 
1. Continuous operation of the comp
once.
2. Continuous operation of the freezer fan
3. Defrosting heater OFF
4. Every display LED ON
TEST 2
Push the test button 
1. Comp OFF
Reset when the door
once while in the 
2. Freezer fan OFF
is opened.
TEST MODE 1.
3. Defrosting heater OFF
4. Every display LED OFF
(except the refrigerator “Medium” LED)
TEST 3
Push the test button
1. Comp OFF
Reset if the temp of
once while in the 
2. Freezer fan OFF
the defrosting sensor
TEST MODE 2.
3. Defrosting heater ON
is 13 °C or above.
4. Every display LED OFF
(except the refrigerator “High, Medium,
Low” LEDs)
Reset
Push the test button
Reset to the default setting
The compressor will
once while in the
start in 7 minute-delay.
TEST MODE 3.
- 20 -
* LED Check Mode: When the refrigerator temp control button and the quick cooling button are pushed and held together for
1 min or longer, every LED on the display turns on simultaneously.  When the buttons are released, the previous mode is
restored.
Page of 31
Display