DOWNLOAD LG GR-S352QVC Service Manual ↓ Size: 894.17 KB | Pages: 29 in PDF or view online for FREE

Model
GR-S352QVC
Pages
29
Size
894.17 KB
Type
PDF
Document
Service Manual
Brand
Device
Refrigerator
File
gr-s352qvc.zip
Date

LG GR-S352QVC Service Manual ▷ View online

- 11 -
6-2 PTC AND OLP
6
5
3
4
YES
 NO
Normal operation of
Compressor is
impossible or poor.
Separate the PTC from
Compressor and
measure the resistance
between No. 5 and 6
(only RSIR Type) or No.
4 and 5 of PTC with a
Tester or Whistone
Bridge. (Figure 22)
Separate the OLP
from Compressor and
check resistance
value between two
terminals of OLP with
a Tester. (Figure 23)
Observation value is
220V/50Hz : 22 
±30%
115V/60Hz : 6.8 
±30%
240V/50Hz : 33 
±30%
127, 220V/60Hz : 
22 
±30%
The resistance value is
0 or several 
hundreds
.
The value is 
∞.
Check another
electric components.
Replace OLP.
Check another
electric components.
Replace
PTC.
Figure  23
Figure  22
- 12 -
6-3 ANOTHER ELECTRIC COMPONENTS
Cooling is impossible
Compressor
doesn't run.
Running state of
Compressor is poor.
Check a starting
voltage.
Check if current flows to
the following
components.
a. Thermistor
b. Starting devices
c. OLP
d. Compressor coil
e. Circuit Parts
Low voltage.
Poor contacting.
Shorted or broken.
Poor contacting
or shorted.
Coil shorted.
Poor contacting
or shorted.
Poor contacting
and broken.
Shorted.
Lack of capacity.
Coil of motor
Compressor.
Replace
the compressor.
Replace
each component.
Raise the voltage.
Replace
each component.
Cause.
Check if current flows
to starting devices.
Check current flowing
in sub-coil of
Compressor.
Check capacity of OLP.
The items described
above are normal.
▼ 
Cooling ability is poor
Fan motor
doesn't run.
Much frost are sticked
to the EVAPORATOR.
Poor contacting.
Coil is shorted.
Shorted.
Replace
each component.
Replace
each component.
Replace
each component.
Check current flowing
in door S/W.
Check current flowing
in the Fan Motor.
Check current flowing
of the following
components.
• Def. Sensor
• FUSE-M
Check current flowing
of the following
components. 
• Sheath Heater
- 13 -
COMPLAINT
POINTS TO BE CHECKED
REMEDY
Cooling is
• Is the power cord unplugged from the outlet?
• Plug to the outlet.
impossible.
• Check if the power S/W is set to OFF.
• Set the switch to ON.
• Check if the fuse of power S/W is shorted.
• Replace a regular fuse.
• Measure the voltage of power outlet.
• If voltage is low, wire newly.
Cooling ability
• Check if the set is placed close to wall.
• Place the set with the space of about 10cm.
is poor.
• Check if the set is placed close to stove, gas
• Place the set apart from these heat
• 
cooker and direct rays.
• 
appliances.
• Is the ambient temperature high or 
• Make the ambient temperature below.
• 
the room door closed?
• Check if putting in hot foods.
• Put in foods after they get cold.
• Did you open the door of the set too often 
• Don't open the door too often and close
• 
or check if the door is closed up?
• 
it firmly.
• Check if the Control is set to "Min".
• Set the control to mid-position.
Foods in the
• Are foods placed in cooling air outlet?
• Place foods in high temperature section.
Refrigerator
• 
(Front Part)
are frozen.
• Check if the Display LED is set to "Max".
• Set the Display LED to "Mid".
• Is the ambient temperature below 5°C?
• Set the Display LED to "Min".
Dew or ice
• Is watery foods kept?
• Seal up watery foods with wrap.
forms in the
• Check if putting in hot foods.
• Put in foods after they get cold.
chamber of
• Did you open the door of the set too  
• Don't open the door too often and close
the set.
• 
often or check  if the door is closed up.
• 
it firmly.
Dew forms
• Check if ambient temperature and humidity
• Wipe dew with a dry cloth. This happening
in the Out Case.
of surroumcling air are high.
• 
is solved in low temperature and humidity
• 
naturally.
• Is the gap in the door packed?
• Fill up the gap.
Abnormal
• Is the set positioned in a firm and even place?
• Adjust the Adjust Screw, and position
noise generates.
• 
in the firm place.
• Does any unnecessary objects exist 
• Remove the objects.
• 
in the back side of the set?
• Check if the Drip Tray is not firmly fixed.
• Fix it firmly on an original position.
• Check if the cover of mechanical room 
• Place the cover at an original position.
• 
in below and front side is taken out.
To close the door
• Check if the door packing becomes dirty 
• Clean the door packing.
is not handy.
• 
by filth such as juice.
• Is the set positioned in a firm and even place?
• Position in the firm place and adjust the
• 
Adjust Screw.
• Is too much food putted in the set?
• Keep foods not to reach the door.
Ice and foods
• Check if the inside of the set becomes dirty.
• Clean the inside of the set.
smell unpleasant.
• Did you keep smelly foods without wraping?
• Wrap smelly foods.
• It smells plastic.
• The new products smell plastic, but it is
• 
removed after 1-2 weeks.
In addition to the items described left, refer to the followings to solve the complaint.
Check if dew forms in
the Freezer.
Replace the
Components of
defrosting circuit.
Check Refrigerating
Cycle.
Check the 
Thermistor
Defrosting
is poor.
The cycle
is faulty.
Repair the cycle.
Replace the
Thermistor.
The operation of
the Thermistor is
poor.
6-4 SERVICE DIAGNOSIS CHART
- 14 -
6-5 REFRIGERATING CYCLE
Troubleshooting Chart
Leakage Detection
Observe discharging point of refrigerant which may be in oil discharging part in compressor and hole of evaporator.
YES
YES
Whether Compressor
runs or not.
Whether frost
forms or not in
Evaporator.
Observe the discharging
amount of Refrigerant.
Inject Refrigerant to
Compressor and check
cooling operation.
Clogged by dust.
Gas leakage.
Faulty
Compressor.
Moisture Clog.
Whether oil leaks
or not.
Normal formed frost
Normal amount
No or much amount
(Check the leakage point)
Normal formed
frost in Evaporator 
No frost or forms
in inlet only
Check Comprossor
PARTIAL
Freezer and
Low flowing sound of
A little high
• A little Refrigerant
LEAKAGE
Refrigerator
Refrigerant is heard and
more than
• 
discharges.
don't get cold
frost forms in inlet only
ambient
• Normal cooling is possible
normally.
temperature.
• 
when injecting Refrigerant
• 
of regular amount.
WHOLE
Freezer and
Flowing sound of Refrigerant
Equal to ambient
• No discharging of Refrigerant.
LEAKAGE
Refrigerator
is not heard and frost isn't
temperature.
• Normal cooling is possible
don't get cold
formed.
• 
when injecting Refrigerant
at all.
• 
of regular amount.
PARTIAL
Freeze room and
Flowing sound of Refrigerant
A little high
• Normal discharging of
CLOG
Refrigerator
is heard and frost forms
more than
• 
refrigerant.
don't get cold
in inlet only.
ambient
• The capillary tube is faulty.
normally.
temperature.
WHOLE
Freezer and
Flowing sound of Refrigerant
Equal to ambient
• Normal discharging of
CLOG
Refrigerator
is not heard and frost isn't
temperature.
• 
Refrigerant.
don't get cold.
formed.
MOISTURE
Cooling operation
Flowing sound of Refrigerant
Low than
• Cooling operation restarts
CLOG
stops periodically.
is not heard and frost melts.
ambient
• 
when heating the inlet of
temperature
• 
capillary tube.
COMP-
Freezer and
Low flowing sound of
A little high
• The pressure of high
RESSION
Refrigerator
Refrigerant is heard and
than ambient
• 
pressure part in
don't get cold.
frost forms in inlet only.
temperature.
• 
compressor is low.
NO COMP-
No compressing
Flowing sound of Refrigerant
Equal to ambient
• No pressure of high pressure
RESSION
operation.
is not heard and no frost.
temperature.
• 
part in compressor.
CAUSE
TEMPERATURE
OF THE
COMPRESSOR
REMARKS
STATE OF
THE SET
STATE OF THE
EVAPORATOR
LEAKAGE
CLOGGED
BY
DUST
DEFECTIVE
COMPRESSION
Page of 29
Display