7-1-10 ERROR DIAGNOSTIC MODE
1. The error diagnostic mode allows the SVC when a fault that may affect the performance of the product occurs while
operating the product.
2. Even if the function control button is pushed when an error occurs, the function will not be performed. However, the
recognition tone (beep~) sounds.
3. When the error is cleared while the error code is displayed due to a fault, the appliance returns to the normal condition
(Reset).
4. The error code is displayed by the refrigerator temp indication LED on the display of the refrigerator while the remaining
LEDs are off.
- 21 -
Error Code
Display
NO
Error
Error Code 
Cause
State of Operation with Error
Display
Comp
Cooling fan
Defrosting heater
1
2
3
4
Faulty refrigerator
(R) sensor 
Faulty defrosting
sensor
Faulty Room
temperature sensor 
(in the main PCB)
Defrosting failure
r
d
when checking
LED, the error
code display all off.
H
Cut or short-circuited wire of
refrigerator sensor
Cut or short-circuited wire of
defrosting sensor
Cut or short-circuited wire of
intake air temperature sensor
Cut or disconnected wire of
defrosting heater or temperature
fuse(indicated at least 4 hours
later after the error occurs)
15 min ON/
15 min OFF
standard
RPM
standard
RPM
standard
RPM
standard
RPM
No defrosting
7-1-11 TEST MODE
1. The test mode allows checking the PCB and the function of the product as well as finding out the defective part in case of
an error.
2. The test button is on the main PCB of the refrigerator (Test S/W).  The test mode will be cleared in 2 hours regardless of
the type of the test mode and then reset.
3. While in the test mode, the function control button is not recognized though the recognition tone (beep~) sounds.
4. After exiting the test mode, be sure reset by unplugging and then plugging in the appliance.
5. If an error, such as a sensor failure, is detected while in the test mode, the test mode is cleared and the error code is displayed.
6. While an error code is displayed, the test mode will not be activated even if the test button is pushed.
Mode
Manipulation
Contents
Remark
TEST 1
Push the test button 
1. Continuous operation of the comp
once.
2. Continuous operation of the freezer fan
3. Defrosting heater OFF
4. Every display LED ON
TEST 2
Push the test button
1. Comp OFF
Reset if the temp of
once while in the 
2. Freezer fan OFF
the defrosting sensor
TEST MODE 1.
3. Defrosting heater ON
is 10 °C or above.
4. Every display LED OFF
(except the refrigerator temp'
status LEDs)
Reset
Push the test button
Reset to the default setting
The compressor will
once while in the
start in 7 minute-delay.
TEST MODE 2.
- 22 -
* LED Check Mode: When the refrigerator temp control button and the Super Cool button are pushed and held together for 1 sec
or longer, every LED on the display turns on simultaneously.  When the buttons are released, the previous mode is restored.
* FAN RPM VARIETY CHECK : Press super cool button and the refrigerator temp control button are pushed and held
together for 1 sec or longer, FAN RPM is reversed for 30 second (HIGH 
↔ 
STANDARD) and return to the previous condition.
<TEST MODE2 STATUS LED>
<TEST MODE1 STATUS LED>
7-2 PCB FUNCTION
7-2-1 POWER CIRCUIT
TRANS 2nd part 
is composed of the RELAY-operating POWER(12Vdc) and power (5Vdc) supplying POWER to MICOM
and IC.
TRANS 2nd part 
is composed of the CIRCUIT supplying POWER(12Vdc) to DISPENSER PUMP MOTOR.
Voltage of each part is as follows.
VA1 is a part preventing from over-voltage and noise.
- 23 -
PART 
PART
both ends of VA1
both ends of CE1
both ends of CE2
both ends of CC2
VOLTAGE
220 Vac
17 Vdc
12 Vdc
5 Vdc
PART 
PART
both ends of 2nd part
both ends of CE6
both ends of CE7
VOLTAGE
13 Vdc
15 Vdc
12 Vdc
7-2-2 OSCILLATION CIRCUIT
This circuit is to generate the base clock for calculating time and the synchro clock for transmitting data from and to the
inside logic elements of the IC1(MICOM).  Be sure to use the authentic parts since the calculating time by the IC1 may be
changed or it will not work if the OSC1 SPEC is changed.
7-2-3 RESET CIRCUIT
The RESET circuit is for allowing all the functions to start at the initial conditions by initializing various parts including the
RAM inside the MICOM (IC1) when the power is initially supplied or the power supply to the MICOM is restored after a
momentary power failure.  For the initial 10ms of power supply, ‘LOW’ voltage is applied to the MICOM RESET terminal.
During a normal operation, 5V is applied to the RESET terminal. (If a trouble occurs in the RESET IC, the MICOM will not
work.)