7-2-9 DISPENSER PUMP MOTOR OPERATION CIRCUIT(OPTION)
Press the DISPENSER PUMP S/W, the MOTOR turns a forward rotate and release the S/W the MOTOR is stop for 0.6
second and turns a reverse rotate for 0.5 second.
- 30 -
A FORWARD
A REVERSE
STOP
ROTATE
STOP
ROTATE
STOP
PUMP S/W OPERATION
PUMP MOTOR
OPERATION
PUMP S/W PART
both ends of CC11
H
L
H
H
H
NO. 11 of IC1
H
H
H
L
H
PUMP MOTOR
NO. 12 of IC1
H
L
H
H
H
PART
VOLTAGE CHECK
as MULTIMETER
0V
12V
0V
-12V
0V
(connect 
+, 
–)
0.6 sec
0.5 sec
RELEASE
PRESS
A FORWARD
ROTATE
STOP
A REVERSE
ROTATE
CHECK POINT
MOTOR OPERATION
STATE
- 31 -
7-3. RESISTANCE SPECIFICATION OF SENSOR
• The resistance of SENSOR has ±5% common difference.
• Measure the resistance of SENSOR after leaving it over 3 minutes in measuring temperature.
This postponing is necessary because of perceiving speed.
• Measure the F-SENSOR, SUPER FROST SENSOR, R1, R2-SENSOR after disconnect CON5 of PWB ASSY, MAIN.
TEMPERATURE SENSOR
RESISTANCE OF FREEZER
RESISTANCE OF REFRIGERATOR
SENSOR
(DEFROST) SENSOR
- 20 ˚C
22.3 K
77 K
- 15 ˚C
16.9 K
60 K
- 10 ˚C
13.0 K
47.3 K
- 5 ˚C
10.1 K
38.4 K
0 ˚C
7.8 K
30 K
+ 5 ˚C
6.2 K
24.1 K
+ 10 ˚C
4.9 K
19.5 K
+ 15 ˚C
3.9 K
15.9 K
+ 20 ˚C
3.1 K
13 K
+ 25 ˚C
2.5 K
11 K
+ 30 ˚C
2.0 K
8.9 K
+ 40 ˚C
1.4 K
6.2 K
+ 50 ˚C
0.8 K
4.3 K
7-1-2 SUPER COOL
1. This feature is to shorten the cooling time of the refrigerator by keeping the comp, fan running for a while. When the
Super Cool button is pushed, the Super Cool LED turns on in order and the comp keeps on running. In 2 hours, the
Super Cool mode will be cleared.
2. When the Defrosting mode starts while in the Super Cool mode, defrosting is performed.  After that, the Super Cool mode
resumes for the remaining time.
3. When the Super Cool button is pushed while in the Defrosting mode, the Super Cool mode starts in 7 minutes after the
completion of the defrosting even though the Super Cool LED turns on.
4. If a power failure occurs while in the Super Cool mode, the Super Cool mode will be cancelled when the power is
restored.
5. If the Super Cool mode is selected when it has not passed 7 minutes since the comp stopped, the comp will start running
after the remaining time elapses.
6. In Super Cool mode, Freezer fan motor operates with 1750 RPM.
7-1-3 OPERATION OF FROM THE FRONT AND THE REAR LED
1. For 2 minutes while the door of the freezer or the refrigerator is open or after it is
closed, the LED turns on in the order of       ,
,
,
,
,
,
,
,
,
,
,
,
and then the all LEDs are kept on.
2. While the LED turns on as described above, the sensor detects the location of the
food and so on.
7-1-4 CONTROL OF VARIABLE SPEED FAN IN THE FREEZER COMPARTMENT
1. Fan motor in the freezer compartment shall change from standard to high speed rpm in order to increase cooling speed
and load corresponding speed.
2. Hign speed rpm is only used for the initial power application, super cool mode and load corresponding operation. But
standard rpm is used in the general working conditions.
3. When the door of freezer room or refrigerator room is opened, the FAN MOTOR is stoped immediately, then when the
door is closed, the FAN DOOR is operated.
7-1-5 ALARM FOR OPEN DOOR
1. This feature is to alarm by the buzzer when the door of the freezer or the refrigerator is not closed in 1 minute after it is
opened.
2. In 1 minute after the door is opened, the buzzer sounds three times at the interval of 0.5 second.  After that, every 30
seconds, the buzzer sounds three times with 0.5 sec ON/OFF.
3. The alarming is cancelled when the door of the freezer or the refrigerator is closed while the buzzer sounds.
D
F
E
G
B
C
A
- 19 -
FREEZER OR
REFRIGERATOR
DOOR
BUZZER
CLOSE
OPEN
CLOSE
OPEN
CLOSE
three
times
three
times
three
times
three
times
within
1 minute
1 minute
30
seconds
30
seconds
(EX.)
A
B
B
C
D
E
F
A
D
F
A
D
F
G
C
E
G
7-1-6 BUZZER SOUND
1. When the button on the front Display is pushed, “Ding-” sound is produced and it works as follows.
7-1-7 CONTROL OF DOUBLE COOLING FAN IN THE REFRIGERATOR COMPARTMENT.
1. To raise the refrigerating speed, fan motor in the refrigerator compartment is operated when the door of freezer room or
refrigerator room is opened and then closed.
2. The fan motor is stoped after 20 sec. when the door is closed.
7-1-8 DEFROSTING
1. The defrosting is performed each time when the total running time of the compressor reaches 7 hours.
2. After the power is turned on (or restored after a power failure), the defrosting starts when the total running time of the
compressor reaches 4 hours.
3. When the temperature of the defrosting sensor reaches 10 °C or above, the defrosting stops.  If the temperature does not
reach 10 °C in 2 hours after the defrosting starts, the defrosting error code is displayed. 
(Refer to 7-1-10. Error Diagnostic Mode.)
4. With the defective defrosting sensor (cut or short-circuited wire), the defrosting will not be performed.
7-1-9 SEQUENTIAL OPERATION OF ELECTRIC COMPONENTS
The electric components, such as the comp, defrosting heater, and cooling fan, start sequentially to avoid the noise and
damage to the part, which may result from the simultaneous start of various components on turning the power on or after
the completion of a test.
Condition of Operation
Operating Sequence
If the temp of the defrosting 
sensor is 45 °C or above
(For the initial use after the 
purchase or grounding)
If the temp of the defrosting 
sensor is below 45 °C
(After a power failure or SVC)
When returned from the Test mode
- 20 -
POWER
in 0.5 sec
COMP
in 0.5 sec
COOLING FAN
ON
ON
ON
ALL LOADS
in 7 min
COMP
in 0.5 sec
COOLING FAN
OFF
ON
ON
POWER
in 0.5 sec
DEFROSTING
in 10 sec
DEFROSTING
ON
HEATER ON
HEATER OFF
in 0.5 sec
COMP
in 0.5 sec
COOLING FAN
ON
ON
When the power is turned on
Page of 39