DOWNLOAD LG MG-5355D Service Manual ↓ Size: 601.37 KB | Pages: 24 in PDF or view online for FREE

Model
MG-5355D
Pages
24
Size
601.37 KB
Type
PDF
Document
Service Manual
Brand
Device
Microwave Oven
File
mg-5355d.zip
Date

LG MG-5355D Service Manual ▷ View online

6-5
4. LATCH BOARD PARTS
W030
4001
4002
4003
4004
4006
4005
4000
6-6
5. INTERIOR PARTS
W067
W074
5015
5003
5013
5020
W030
W067
5019
5012
5021
5011
5024
5022
5025
W101
W101
W074
5017
5009
W143
5010
W112
5005
W067
W106
5004
5000
5007
5002
5001
W143
5006
5022
5023
W143
W081
6-7
6. BASE PLATE PARTS
6001
6005
6003
W106
W049
W067
W101
6004
6002
W108
W143
5-1
NECESSARY TOOLS
Tools normally used for TV servicing are sufficient.
Standard tools are listed below.
Diagonal pliers
Long nose pliers
Cross head screwdriver
Wrench (size 5 mm)
Nutdriver (size 5 mm)
Adjustable wrench
Soldering iron
Solder
Vinyl insulation tape
Polishing cloth
NECESSARY MEASURING INSTRUMENTS
TESTER (VOLTS-DC, AC, Ohmmeter)
Microwave survey meter
— Holaday HI-1500, HI-1501
— Narda    8100, 8200
Inch scale
600 cc non conductive material beaker (glass or
plastic), inside diameter: approx. 8.5cm (3
1/2
in.)
Cylindrical and made of borosilicate glass vessel
max.
thickness: 3mm
outside diameter: approx. 190mm
height: approx. 90mm
Glass thermometer: 100°C or 212°F (1 deg scale)
SERVICE INFORMATION 
Tools and Measuring Instruments
CAUTIONS
Be sure to check a microwave emission prior to ser-
vicing the oven if the oven is operative prior to ser-
vicing.
If the oven operates with door open, the service
personnel should;
— Tell the user not to operate the oven
The service personnel should check all surface and
vent openings for microwave emission testing. 
Check for microwave energy leakage after every
servicing. The power density of the microwave radi-
ation leakage emitted by the microwave oven
should not exceed 4 mW/cm
2
And always start measuring of an unknown field to
assure safety for operating personnel from radia-
tion leakage.
NOTE: The standard is 5 mW/cm
2
while in the cus-
tomer's home. 4 mW/cm
2
stated here is manufac-
turer's own voluntary standard for units in cus-
tomer's home.
EQUIPMENT
Microwave Survey Meter
600cc glass beaker
Glass thermometer 100°C
MEASURING MICROWAVE ENERGY
LEAKAGE
Pour 275
±
15cc of 20°C
±
5°C water in a beaker
which is graduated to 600 cc, and place the beaker
on the center of the turntable.
Set the energy leakage monitor to 2,450 MHz and
use it following the manufacturer's recommended
test procedure to assure correct result.
When measuring the leakage, always use the 2
inch (5cm) spacer supplied with the probe.
Operate the oven at its maximum output.
Measure the microwave radiation using and electro-
magnetic radiation monitor by holding the probe
perpendicular to the surface being measured.
Microwave Leakage Test
Move probe along shaded area.
Probe scanning speed;
Less than 2.5 cm/sec
Page of 24