—5—
1.4 FEATURES
• Designed for COOLING ONLY
• Powerful and whispering cooling.
• Slide-in and slide-out chassis for the simple
installation and service.
• Side air-intake, side cooled-air discharge.
1.5 CONTROL LOCATIONS
1.5.1 COOLING ONLY MODEL
• VENTILATION
The ventilation lever must be in the CLOSE position
in order to maintain the best cooling conditions.
When a fresh air is necessary in the room, set the
ventilation lever OPEN position.
The damper is opened and room air is exhausted.
• THERMOSTAT
Thermostat will automatically control the
temperature of the room. Select a higher number for
a cooler temperature in the room. The temperature
is selected by positioning the knob to the desired
position.
The  or  position is a normal setting for average
conditions.
• OPERATION
Off
(
)
: Turns the air conditioner off.
MED FAN
(        )
: Permits the medium fan speed
operation without cooling.
LOW FAN
(        )
: Permits the low fan speed
operation without cooling.
HIGH COOL (        )
: Permits cooling with the
high fan speed operation.
MED COOL (        )
: Permits cooling with the
medium fan speed
operation.
LOW COOL (        )
: Permits cooling with the low
fan speed operation.
• AUTO SWING
ON
(
)
: Air swing is operated while
OPERATION knob is set to
the COOL position.
OFF
(        )
: Stops the operation of air
swing.
• Built-in adjustable THERMOSTAT
• Washable one-touch filter
• Compact size
• Reliable and efficient rotary compressor is equipped.
CLOSE
VENT
OPEN
1
Thermostat
Operation
2
3
4
9
8
7
6
5
Off
Med
Fan
Low
Fan
High
Cool
Med
Cool
Low Cool
1
Thermostat
Operation
2
3
4
9
8
7
6
5
Off
Med
Fan
Low
Fan
High
Cool
Med
Cool
Low Cool
0
0
On
Off
Auto Swing
0
—6—
1.5.2 HEAT PUMP MODEL
• HEATER LAMP
When the unit sets heating operation condition, the
green lamp is lighted.
When the frost settles on the heat exchanger of the
outside, defrosting is made automatically and the
green lamp is unlighted. The until it may hiss and
the fan motor will stop for 1 to 10 minutes.
This should not be regarded as trouble. After
defrosting, the heating operation begins again.
• THERMOSTAT
Turn the thermostat control to the desired setting.
The central position is a normal setting for average
conditions. You can change this setting, if
necessary, in accordance with your temperature
preference.
The thermostat automatically controls cooling or
heating, but the fan runs continuously whenever
the air conditioner is in operation. If the room is
too warm, turn the thermostat control clockwise. If
the room is too cool, turn the themostat control
counterclockwise.
• OPERATION
OFF
(       ) : Turns the air conditioner off.
LOW FAN
(       ) : Permits the low fan speed
operation without cooling  
(or heating).
LOW COOL (       ) : Permits cooling with the low
fan speed operation.
HIGH COOL (       ) : Permits cooling with the high 
fan speed operation.
LOW HEAT  (       ) : Permits heating with the low 
fan speed operation.
HIGH HEAT (       ) : Permits heating with the high 
fan speed operation.
(TYPE1)
(TYPE2)
0
THERMOSTAT
OPERATION
COOLER
WARMER
HEATER
COO
L
H
EA
T
Thermostat
Warmer
Cooler
Heater
Operation
—7—
1.5.2 COOLING AND HEATING MODEL WITH REMOTE CONTROL AND TOUCH TYPE
POWER BUTTON
Operation starts, when this button is pressed and stops when you press the button again.
OPERATION MODE SELECTION BUTTON
Select Cooling, Heating, or Fan mode with this button.
ON/OFF TIMER BUTTON
Set the time of starting and stopping operation. The timer is set by 1 hour.
FAN SPEED SELECTOR
Select the fan speed. Cooling Model: 3 steps {High[F3
Low[F1
Med[F2]
High[F3]... }
Heating Model: 2 steps {High [F2
Low[F1
High[F2]... }
ROOM TEMPERATURE SETTING BUTTON
Control the room temperature within a range of 16°C to 30°C. The room temperature will be adjusted by 1˚C 30min., and
by 2˚C 1 hour later.
SIGNAL RECEIVER
AUTO SWING
The vertical louver swings horizontally by the automatic system and stops when you press the button again.
6
6
7
7
REMOTE CONTROL
DISPLAY
2
3
1
7
6
4
5
2
3
1
6
4
5
2
3
1
6
4
5
1
4
2
3
5
3
1
4
2
8
5
3
1
4
2
5
—8—
2.1 MECHANICAL PARTS
2.1.1 FRONT GRILLE
1. Open the lnlet grille upward .
2. Remove the screw which fastens the front grille.
3. Pull the front grille from the right side.
4. Remove the front grille.
5. Re-install the component by referring to the
removal procedure, above.(See Figure 1)
2.1.2 CABINET
1. After disassembling the FRONT GRILLE, remove
the 2 screws which fasten the cabinet at both
sides.
2. Remove the 2 screws which fasten the cabinet at
back.
3. Pull the base pan forward. (See Figure 2)
4. Remove the cabinet.
5. Re-install the component by referring to the
removal procedure, above.
2.1.3 CONTROL BOX
1. Remove the front grille. (Refer to section 2.1.1)
2. Remove the cabinet. (Refer to section 2.1.2)
3. Remove the 2 screws which fasten the control box
cover.
4. Remove two  housings which connect compressor
wire and motor wire in the control box.
5.Discharge the capacitor by placing a 20,000
ohmresistor across the capacitor terminals.
6. Remove the 2 screws which fasten the control
box.
7. Pull the control box forward completely.
8. Re-install the components by referring to the
removal procedure, above. (See Figure 3)
(Refer to the circuit diagram found on pages
24~25 in this manual and on the control box.)
1
Therm
ostat
Opera
tion
2
3
4
9
8
7
6
5
Off
Med
Fan
Low
Fan
High
Cool
Med
Cool
Low Co
ol
1
Therm
ostat
Opera
tion
2
3
4
9
8
7
6
5
Off
Med
Fan
Low
Fan
High
Cool
Med
Cool
Low Co
ol
1
Therm
ostat
Oper
ation
2
3
4
9
8
7
6
5
Off
Med
Fan
Low
Fan
High
Cool
Med
Cool
Low C
ool
2. DISASSEMBLY INSTRUCTIONS
— Before the following disassembly, POWER SWITCH set to OFF and disconnect the power cord.
Figure 1
Figure 3
Figure 2
Page of 52
Display

Click on the first or last page to see other LWC1264AAG_AAN_ACE_ACF_ACN_ACP_BAG_BCF_BCG_BCS_ACG / LWC1264PAG_PAN_PCG_QAG_QAS_QAE / LWC1264AHE_AHF_AHG_ABG_BBG / LWC1264PBG_PHG_QBG_VBS / LWC126CGAB0 / LWC1264BAE / W12LH service manuals if exist.