21
Possible Trouble 4
FAN does not operate.
• Exchange IC1.
• Exchange IC7.
Is the voltage NO.2 or 3
of IC7 DC 5V?
Is the voltage NO.14 or 15
of IC7 0V?
• Check the RY-High or 
             RY-Low.
• Check the wiring diagram.
NO
NO
YES
YES
Possible Trouble 5
Remote controller does not operate.
Is the voltage of Battery
about over 2•3V?
• Exchange Receiver Ass'y.
Is the connection of 
CN-DISP2 all right?
Is the voltage No.7 
of CN-DISP2 on Main PCB 
Ass'y DC 5V?
• Exchange the battery.
• Check the PCB pattern.
• Connect connector to 
  CN-DISP2 exactly.
NO
NO
NO
YES
YES
YES
22
Possible Trouble 6
It displays abnormally on display PCB Ass'y.
NO
NO
NO
NO
YES
YES
YES
Is the IC6 all right?
Is the connection of 
CN-DISP1 all right?
• Exchange the display 
  PCB Ass'y. 
• Exchange IC6.
• Exchange TR1, 
  TR2, TR3.
• Connect connector 
  to CN-DISP1 exactly.
Does the TR1, 
TR2, TR3 operate normally
on main PCB Ass'y?
Possible Trouble 7
The function of Auto Restart does not operate.
NO
NO
YES
YES
Is the Knob of SW1
set to left position?
Is the voltage No.3 of 
CN-DISP2 of Main PCB
Ass'y DC 5V?
• Reference to 
  OWNER'S MANUAL.
• Set the Knob of SW1 
  to left position.
• Check the SW1.
• Check the pattern of 
  Main & Display PCB.
23
COMPLAINT
CAUSE
REMEDY
Check voltage at outlet. Correct if none.
Check voltage to rotary switch. If none, check
power supply cord. Replace cord if circuit is open.
Check switch continuity. Refer to wiring diagram
for terminal identification. Replace switch if
defective.
Connect wire. Refer to wiring diagram for terminal
identification. Repair or replace loose terminal.
Test capacitor.
Replace if not within ±10% of manufacturer's
rating. Replace if shorted, open, or damaged.
Fan blade hitting shroud or blower wheel hitting
scroll. Realign assembly.
Units using slinger ring condenser fans must
have 
1
/
4
to 
5
/
16
inch clearance to the base. If it is
hitting the base, shim up the bottom of the fan
motor with mounting screw(s).
Check fan motor bearings; if motor shaft will not
rotate, replace the motor.
Check voltage. If not within limits, call an
electrician.
Test capacitor.
Check bearings. Does the fan blade rotate freely.
If not, replace fan motor.
Pay attention to any change from high speed to
low speed. If the speed does not change, replace
the motor.
Check grommets; if worn or missing, replace them.
If cracked, out of balance, or partially missing,
replace it.
If cracked, out of balance, or partially missing,
replace it.
Tighten it.
If knocking sounds continue when running or
loose, replace the motor. If the motor hums or
noise appears to be internal while running,
replace motor.
No power
Power supply cord
Rotary switch
Wire disconnected or
connection loose
Capacitor. (Discharge
capacitor before testing.)
Will not rotate
Revolves on overload.
Grommets
Fan
Blower
Loose set screw
Worn bearings
Fan motor will not run.
Fan motor runs inter-
mittently
Fan motor noise.
24
COMPLAINT
CAUSE
REMEDY
Check voltage. See the limits on the preceding
page. If not within limits, call an electrician.
Check the wire connections, if loose, repair or
replace the terminal. If wires are off, refer to wiring
diagram for identification, and replace. Check wire
locations. If not per wiring diagram, correct.
Check for continuity, refer to the wiring diagram
for terminal identification. Replace the switch if
circuit is open.
Check the position of knob If not at the coldest
setting, advance the knob to this setting and
restart unit.
Check continuity of the thermostat. Replace
thermostat if circuit is open.
Check the capacitor.
Replace if not within ±10% of manufacturers
rating. Replace if shorted, open, or damaged.
Check the compressor for open circuit or
ground. If open or grounded, replace the
compressor.
Check the compressor overload, if externally
mounted. Replace if open. (If the compressor
temperature is high, remove the overload, cool it,
and retest.)
Check the voltage. See the limits on the preced-
ing page. If not within limits, call an electrician.
Check overload, if externally mounted.
Replace if open. (If the compressor temperature
is high, remove the overload, cool, and retest.)
If not running, determine the cause. Replace if
required.
Remove the cabinet. Inspect the interior surface
of the condenser; if restricted, clean carefully
with a vacuum cleaner (do not damage fins) or
brush. Clean the interior base before
reassembling.
If condenser fins are closed over a large area
on the coil surface, head pressures will increase,
causing the compressor to cycle. Straighten the
fins or replace the coil.
Test capacitor.
Check the terminals. If loose, repair or replace.
Voltage
Wiring
Rotary switch
Thermostat
Capacitor (Discharge
capacitor before
servicing.)
Compressor
Overload
Voltage
Overload
Fan motor
Condenser air flow
restriction.
Condenser fins
(damaged).
Capacitor
Wiring
Compressor will not run,
but fan motor runs.
Compressor cycles
on overload.
Compressor cycles on
overload (Cont'd)
Page of 35