DOWNLOAD LG LS-K1863HL Service Manual ↓ Size: 2.62 MB | Pages: 70 in PDF or view online for FREE

Model
LS-K1863HL
Pages
70
Size
2.62 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
ls-k1863hl.zip
Date

LG LS-K1863HL Service Manual ▷ View online

Warning :
Disconnect the unit from power supply before making
any checks.
Be sure the power switch is set to “OFF”. 
To remove the Grille from the Chassis
• Set the up-and-down air discharge louver to open
position (horizontally) by finger pressure.
• Remove the securing screws
• To remove the Grille, pull the lower left and right side
of the grille toward you (slightly tilted) and lift it
straight upward.
To remove the Grille from the Chassis 
• Remove the cover control
from the grille
.
• Separate the black lead wire from the white 
connector.
•  Remove screws secured (
3 EA).
•  Pull the grille
out from the chassis carefully.
1. To remove the sensor, housing connect, earth
conductor & step motor conductor with sensor
holder, Motor, Evaporator & P.C.B.
- 42 -
LS-K2424/1864/2466/2666/2467/2468HL/HM/HN/BL/EL
Screw
(3EA)
Power
Conductor
Step Motor
Conductor
Earth
Conductor
Motor
Conductor
Sensor
Conductor
BLACK
WHITE
1
3
2
2. To remove the Control Box.
• Remove 2 securing screws. 
• Pull the control box out from the chassis carefully.
3. To remove the Discharge Grille.
• Remove the securing screw. 
• Pressing the right side of the discharge grille
downward slightly, unhook the discharge grille.
• Pull the discharge grille out from the chassis
carefully. 
4. To remove the Evaporator. 
• Remove 3 screws securing the evaporator(at the
left 1EA, at the right 2EA).
- 43 -
• Unhook the tab on the right inside of the chassis
at the same time, slightly pull the evaporator
toward you until the tab is clear of the slot. 
5. To remove the Cross-Flow Fan
• Loosen the screw securing the cross-flow fan to
the fan motor (do not remove).
• Lift up the right side of the cross-flow fan and the
fan motor, separate the fan motor from the
cross-flow fan.
• Remove the left end of the cross-flow fan from
the self-aligning bearing. 
- 44 -
- 45 -
2-way, 3-way Valve
2-way Valve (Liguid Side)
3-way Valve (Gas Side)
Works
Shaft position
Shaft position
Service port
Shipping
Closed
Closed
Closed
(with valve cap)
(with valve cap)
(with cap)
Air purging
Open
Closed
Open
(Installation)
(counter-clockwise)
(clockwise)
(push-pin or with 
vacuum pump)
Operation
Open
Open
Closed
(with valve cap)
(with valve cap)
(with cap)
Pumping down
Closed
Open
Open
(Transfering)
(clockwise)
(counter-clockwise)
(connected 
manifold gauge)
Evacuation
Open
Open
Open
(Servicing)
(with vacuum  
pump)
Gas charging
Open
Open
Open
(Servicing)
(with charging 
cylinder)
Pressure check
Open 
Open
Open
(Servicing)
(with charging 
cylinder)
Gas releasing
Open
Open
Open
(Servicing)
(with charging 
cylinder)
1.
2.
3.
4.
5.
6.
To outdoor unit
Hexagonal wrench (4mm)
Open position
Closed position
To 
piping 
connection
Flare nut
Valve cap
Open position
Closed position
Pin
Service
port
Service
port cap
To outdoor unit
Flare nut
To 
piping 
connection
Page of 70
Display

Click on the first or last page to see other LS-K1863HL service manuals if exist.