DOWNLOAD LG LS-J0763EL Service Manual ↓ Size: 4.3 MB | Pages: 127 in PDF or view online for FREE

Model
LS-J0763EL
Pages
127
Size
4.3 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
ls-j0763el.zip
Date

LG LS-J0763EL Service Manual ▷ View online

-28-
Outdoor unit 
Liquid side piping
(Smaller Dia.)
Torque wrench
Gas side piping
(Bigger Dia.)
1) Connecting the piping to the Outdoor
unit
1. Align the center of the piping and sufficiently
tighten the flare nut with fingers.
2. Finally, tighten the flare nut with torque wrench
until the wrench clicks.
• When tightening the flare nut with torque wrench,
ensure the direction for tightening follows the arrow
on the wrench.
CAUTION
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have an individual power specialized for the air conditioner. As for the method of wiring,
be guided by the circuit diagram pasted on the inside of control box cover.
2) Provide a circuit breaker switch between power source and the unit.
3) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from
vibrations to which the unit is subjected during the course of transportation. Check them and make
sure that they are all tightly fastened. (If they are loose, it could give rise to burn-out of the wires.)
4) Specification of power source.
5) Confirm that electrical capacity is sufficient.
6) See to it that the starting voltage is maintained at more than 90 percent of the rated voltage marked
on the name plate.
7) Confirm that the cable thickness is as specified in the power sources specification.
(Particularly note the relation between cable length and thickness.)
8) Never fail to equip a leakage breaker where it is wet or moist.
9) The following troubles would be caused by voltage drop-down.
• Vibration of a magnetic switch, damage on the contact point there of, fuse breaking, disturbance to the nor-
mal function of a overload protection device.
• Proper starting power is not given to the compressor.
3. Connecting Piping and Cable to the outdoor unit
Pipe Size
Torque
Liquid Side (1/4")
1.8kg.m
Gas Side (3/8")
4.2kg.m
Gas Side (1/2")
5.5kg.m
Connecting 
cable
Terminal block
(Pillar terminal)
Cover control
Outdoor unit
Over
5mm
Holder for 
connecting 
cable
Over 5mm
Terminal block
(Pillar terminal)
Holder for
power supply
cord
Cover control
Connecting cable
-29-
2) Connection of the cable
1. Remove the cover control from the unit by loos-
ening the screw.
Connect the wires to the terminals on the control
board individually as the following.
Outdoor unit
2. Secure the cable onto the control board with the holder
(clamper).
3. Refix the cover control to the original position with the
screw.
4. Use a recognized circuit breaker 16A between the power
source and the unit. A disconnection device to adequately
disconnect all supply lines must be fitted.
1(L)
Terminals on the outdoor unit
Terminals on the outdoor unit
Terminals on the indoor unit
Terminals on the indoor unit
1(L)
1(L)
1(L)
2(N)
2(N)
2(N)
3
4
3
4
2(N)
BROWN BLUE
G/Y
BLACK
RED
BROWN BLUE
G/Y
RED
BROWN
BROWN BLUE
BLACK
BLACK
G/Y
RED
RED
G/Y
BLUE
BROWN
BLUE GREEN/YELLOW
BROWN
BLUE GREEN/YELLOW
1) Cooling only type
2) Cooling & Heating type
The power cord connected to the indoor unit should
be complied with the following specifications (Type
H05VV-F approved by HAR or SA).
The connecting cable connected to the indoor and
outdoor unit should be complied with the following
specifications (Rubber insulation, type H07RN-F
approved by HAR or SA).
NORMAL CROSS-
SECTIONAL AREA
1.0mm
2
NORMAL CROSS-
SECTIONAL AREA
1.0mm
2
Color of Wires
Color of Wires
The length of the power supply cord should be over 1.8m measured from the power supply cord entry of the cabinet to the
middle of the live pin of the plug.
Color of Wires
Color of Wires
LS-J0761HL/CL
LS-J0821CL
LS-J0962CL
LS-J0964HL
-37-
Operation 
(1) Name and Function-Remote Control (Cooling Models)
Signal transmitter
Transmits the signals
to the room air conditioner.
Remote Control 
ON
OFF
SET
CANCEL
Signal transmitter
9
10
11
5
1
12
2
6
13
4
3
7
8
START/STOP BUTTON
Operation starts when this button is pressed and stops
when the button is pressed again.
ROOM TEMPERATURE SETTING BUTTONS
Used to select the room temperature.
INDOOR FAN SPEED SELECTOR
Used to select fan speed in four steps
low, medium, high, or CHAOS.
JET COOL
Used to start or stop the speed 
cooling. (Speed cooling operates 
super high fan speed in cooling mode.)
CHAOS SWING BUTTON
Used to stop or start louver movement and 
set the desired up/down airflow direction.
ON/OFF TIMER BUTTONS
Used to set the time of starting and stopping operation.
TIME SETTING BUTTONS
Used to adjust the time.
TIMER SET/CANCEL BUTTONS
Used to set the timer when the desired time is obtained
and to cancel the Timer operation.
SLEEP MODE AUTO BUTTON
Used to set Sleep Mode Auto operation.
AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or heating
(turns indoor fan on/off).
ROOM TEMPERATURE CHECKING BUTTON
Used to check the room temperature.
RESET BUTTON
Used prior to resetting time or after replacing batteries.
OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
1
2
3
4
5
6
7
8
9
10
11
12
13
-38-
(2) Name and Function-Remote Control  (Heat Pump Models)
Signal transmitter. 
Transmits the signals
to the room air conditioner.
Remote Controller 
ON
OFF
SET
CANCEL
Signal transmitter
4
5
6
7
9
8
1
2
3
PLASMA(or      )
ON/OFF TIMER BUTTONS
Used to set the time of starting and stopping operation.
TIME SETTING BUTTONS
Used to adjust the time.
TIMER SET/CANCEL BUTTONS
Used to set the timer when the desired time is obtained
and to cancel the Timer operation.
SLEEP MODE AUTO BUTTON
Used to set Sleep Mode Auto operation.
AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or heating
(turns indoor fan on/off).
ROOM TEMPERATURE CHECKING BUTTON
Used to check the room temperature.
PLASMA(OPTION)
Used to start or stop the plasma-purification function. 
NEGATIVE ION(OPTION)
Used to generate negative ion. 
HORIZONTAL AIRFLOW DIRECTION CONTROL
BUTTON (NOT ON ALL MODELS)
Used to set the desired horizontal airflow direction. 
RESET BUTTON
Used prior to resetting time or after replacing batteries.
1
2
3
4
5
6
7
8
9
Page of 127