DOWNLOAD LG LS-J0761NL_NM_NN / LS-J0962NL_NM_NN / LS-L1261NL_NM_NN Service Manual ↓ Size: 3.1 MB | Pages: 75 in PDF or view online for FREE

Model
LS-J0761NL_NM_NN LS-J0962NL_NM_NN LS-L1261NL_NM_NN
Pages
75
Size
3.1 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
ls-j0761nl.zip
Date

LG LS-J0761NL_NM_NN / LS-J0962NL_NM_NN / LS-L1261NL_NM_NN Service Manual ▷ View online

-63-
The problem of missing the connector (INDOOR MAIN PCB ASSY)
Connectors
CN-POWER
(AC2)
CN-FAN
CN-DATA
CN-DISP1
CN-DISP2
CN-TH
CN-U/D
Condition
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN/SHORT
OPEN
• Malfunctions all indoor & outdoor unit.
• Malfunctions remocon, force, test operation mode.
• Malfunctions outdoor unit.
• Stop compressor and outdoor fan motor.
• The operation LED blinks 5 times.
• Communicaion error.
• Malfunctions remote contoller.
• Don't operate the power display module.
• Don't operate the power display module.
(LS-_NM Series is not included)
• The operation LED blinks twice.
• Enable to receive remote singnal.
• Malfunctions UP/DOWN step motor.
• Don't operate louver.
• Malfunctions indoor fan motor.
Problem (error mode)
-64-
The problem of missing the connector (SUB PCB ASSY)
Connectors
CN-UVW
CN-AC
CN-DC
CN-IPM
Condition
OPEN
OPEN
OPEN
OPEN
• Stop compressor.
• Malfunctions outdoor unit.
• Stop compressor and outdoor fan.
• The operation LED blinks 5 times.
• Malfunctions PFC & inverter circuit.
• Stop compressor and outdoor fan.
• Malfunctions outdoor unit.
• Stop compressor and outdoor fan.
• The operation LED blinks 5 times.
Problem (error mode)
The problem of missing the connector (OUTDOOR MAIN PCB ASSY)
Connectors
CN-POWER
CN-AC
CN-DC
CN-IPM
CN-GND1,2
CN-4WAY
CN-FAN
CN-OLP
CN-TH
CN-COMP
Condition
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN/SHORT
OPEN/SHORT
OPEN/SHORT
• Malfunctions outdoor unit.
• Stop compressor and outdoor fan.
• The operation LED blinks 5 times.
• Malfunctions outdoor unit.
• Stop compressor and outdoor fan.
• The operation LED blinks 5 times.
• Malfunctions PFC & inverter circuit.
• Stop compressor and outdoor fan.
• Malfunctions EMI /EMS
• Malfunctions 4-WAY valve.
• Malfunctions fan.
• Malfunctions Comp. Motor.
• The operation LED blinks 4 times.
• The LED01K blinks 4 times.
• The operation LED blinks twice.
• The LED01K blinks twice.
• The LED01K blinks 10 times.
• Continue Comp. operation.
(when the discharge pipe TH opens)
• Stop Comp. operation
(when the discharge pipe TH shorts)
• Malfunctions outdoor unit.
• Stop compressor and outdoor fan.
• The operation LED blinks 5 times.
Problem (error mode)
-55-
Turn on main power.
While the compressor has been stopped, the compressor does not operate 
owing to the delaying function for 2 minutes after stopped.
When the compressor stopped Indoor Fan is driven by a low speed.
At this point the wind speed is not controlled by the remote controller.
(When operated in the Sleeping Mode, the wind speed is set to the low speed as force).)
Caused by the remote controller.
Caused by other parts except 
the remote controller
When the mark (       ) is displayed in LCD
screen, replace battery.
Check the contact of CN-DISP 1, 2 connector
When the detect switch (double key) inside the
remote controller door is fault, it is impossible to
operate temperature regulating(
) and wind
speed selecting.
Check DISP PWB Ass'y 
-Voltage between CN1 
➀ 
-
➆ 
: DC +5V
Check the connecting circuit between the
remote controller MICOM(No.30)-R17(2
)-IR-
LED-Tr-R16(2.2k
)
Check point
• Check the connecting circuit between
MICOM PIN 
49
• Check receiver ass'y
Product doesn't operate with the remote controller.
Trouble 2
-56-
Turn on the main power.
When in air circulation mode, compressor/outdoor fan is stopped.
Turn off main power.
Check the electrical wiring diagram of Outdoor side.
Check the open or short of connecting wires between Indoor and Outdoor.
Check the sensor for Indoor temperature is attatched as close as to be effected by the
themperature of Heat Exchange (EVA.)
When the sensor circuit for Indoor temperature and connector are in bad connection or are
not engaged, Compressor/Outdoor fan is stopped.
• Check the related circuit of R02H(12.1K), R01H(1K), R04H(6.2K), R03H(1K), C01H(102),
C02H(102), Micom(pin No. 62,63).
• Check the Indoor temperature sensor is disconnected or not (about 10K at 25°C).
Check the Relay(RY-PWR) for driving Compressor.
• Check the voltage between brown and blue cable of terminal to connect the Outdoor
(About AC220V / 240V).
• Check the related circuit of relay in Outdoor PCB Ass'y.
Operate Cooling Mode by setting the disired temperature of the remote controller is less
than one of the Indoor temperature by 1°C at least.
The Compressor/Outdoor Fan are unable to drive.
Trouble 3
Check Point
Between Micom(No. 19) and
GND
DC 5V
DC 0V
DC 12V
DC 1V
Between IC01M(No. 14) and
GND
Comp. ON
Comp. OFF
Page of 75
Display

Click on the first or last page to see other LS-J0761NL_NM_NN / LS-J0962NL_NM_NN / LS-L1261NL_NM_NN service manuals if exist.