DOWNLOAD LG LS-J0761NL_NM_NN / LS-J0962NL_NM_NN / LS-L1261NL_NM_NN / LS-K1860NL_NM_NN_YL / LS-K181N-1 Service Manual ↓ Size: 11.33 MB | Pages: 127 in PDF or view online for FREE

Model
LS-J0761NL_NM_NN LS-J0962NL_NM_NN LS-L1261NL_NM_NN LS-K1860NL_NM_NN_YL LS-K181N-1
Pages
127
Size
11.33 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
ls-j0761nl-nm-nn-ls-j0962nl-nm-nn-ls-l1261nl-nm-nn.zip
Date

LG LS-J0761NL_NM_NN / LS-J0962NL_NM_NN / LS-L1261NL_NM_NN / LS-K1860NL_NM_NN_YL / LS-K181N-1 Service Manual ▷ View online

-57-
Turn on main power.
While the compressor has been stopped, the compressor does not operate 
owing to the delaying function for 2 minutes after stopped.
When the compressor stopped Indoor Fan is driven by a low speed.
At this point the wind speed is not controlled by the remote controller.
(When operated in the Sleeping Mode, the wind speed is set to the low speed as force).)
Caused by the remote controller.
Caused by other parts except 
the remote controller
When the mark (       ) is displayed in LCD
screen, replace battery.
Check the contact of CN-DISP 1, 2 connector
When the detect switch (double key) inside the
remote controller door is fault, it is impossible to
operate temperature regulating(
) and wind
speed selecting.
Check DISP PWB Ass'y 
-Voltage between CN1 
➀ 
-
➆ 
: DC +5V
Check the connecting circuit between the
remote controller MICOM(No.30)-R17(2
)-IR-
LED-Tr-R16(2.2k
)
Check point
• Check the connecting circuit between
MICOM PIN 
49
• Check receiver ass'y
Product doesn't operate with the remote controller.
Trouble 2
-58-
Turn on the main power.
When in air circulation mode, compressor/outdoor fan is stopped.
Turn off main power.
Check the electrical wiring diagram of Outdoor side.
Check the open or short of connecting wires between Indoor and Outdoor.
Check the sensor for Indoor temperature is attatched as close as to be effected by the
themperature of Heat Exchange (EVA.)
When the sensor circuit for Indoor temperature and connector are in bad connection or are
not engaged, Compressor/Outdoor fan is stopped.
• Check the related circuit of R02H(12.1K), R01H(1K), R04H(6.2K), R03H(1K), C01H(102),
C02H(102), Micom(pin No. 62,63).
• Check the Indoor temperature sensor is disconnected or not (about 10K at 25°C).
Check the Relay(RY-PWR) for driving Compressor.
• Check the voltage between brown and blue cable of terminal to connect the Outdoor
(About AC220V / 240V).
• Check the related circuit of relay in Outdoor PCB Ass'y.
Operate Cooling Mode by setting the disired temperature of the remote controller is less
than one of the Indoor temperature by 1°C at least.
The Compressor/Outdoor Fan are unable to drive.
Trouble 3
Check Point
Between Micom(No. 19) and
GND
DC 5V
DC 0V
DC 12V
DC 1V
Between IC01M(No. 14) and
GND
Comp. ON
Comp. OFF
-59-
When indoor Fan does not operate.
Trouble 4
Check the SSR high speed operation by remote control.
(the Indoor Fan Motor is connected)
Turn off main power.
Check the connection of CN-FAN.
Check the Fan Motor.
Check the Fuse(AC250V, T2A).
Turn on the main power
Check the related circuit of indoor Fan Motor.
• The pin No.10 of micom and the part for driving SSR.
• Check the related pattern.
• Check the SSR.
- SSR Open: Indoor Fan Motor never operate.
- SSR short: Indoor Fan Motor always operates in case of ON or OFF.
The voltage of Pin No 1(orange) and 3(black) of CN-FAN.
About AC 180V over
About AC 50V over
SSR is not damaged
Check SSR
18K Series
LS-K1861YL
LS-K1860NL/YL
LS-K181N-1
LS-K18612L
7K Series
9K Series
12K Series
Cooling Capacity
Btu/h
Heating Capacity
Moisture Removal
l/h
Power Source
Ø, V, Hz
Air Circulation
Indoor
m3/min
Outdoor
Noise Level
Indoor
dB (A)±3
Outdoor
Input
Cooling
W
Heating
Running Cooling
A
Current
Heating
Motor Output
Indoor
W
Outdoor
Dimensions
Indoor
mm
(W x H x D)
Outdoor
Net. Weight
Indoor
kg
Outdoor
Refrigerant (R22)
g
Airflow Direction Control (Up & Down)
Remocon Type
Service Valve
Liquid
inch(mm)
Gas
Sleeping Operation
Drain Hose
Connecting Cable
mm
2
Power Cord
mm
2
at 230V
at 230V
at 230V
at 230V
7,000(4,700-8,300)
9,000(5,200-9,700)
12,000(7,500-13,200) 18,000(11,000-19,800) 17,500(11,000-19,800)
9,000(5,000-10,000)
11,250(4,600-12,500) 14,400(8,300-15,900) 27,700(12,800-22,770) 19,700(12,800-22,770)
1
1.1
1.3
2.5
1Ø, 220-240V, 50Hz
5.6
6.5
8.6
12
25
25
25
42
33
36
39
42
50
50
51
56
740
1,070
1,280
2,000
980
1,300
1,580
2,200
3.3
4.8
5.8
9.0
4.4
6
7
9.5
7.5
7.5
13
20
35.8
35.8
35.8
62
802*262*165
802*262*165
888*287*170
1,080*314*181
801*555*262
870*655*320
7
7
9
15
33
35
41
54
530
650
980
1,250
O
L.C.D Wireless
1/4''(6.35)
1/4''(6.35)
3/8''(9.52)
1/2''(12.7)
O
O
1
1.5
2.5
1
1.5
2.5
-6-
Product Specifications (Cooling & Heating) 
Model Name
Unit
Item
Page of 127
Display