-16-
6. Heating mode operation
• Operating frequency of compressor depend on the difference of the temperature
(= compressor off temp. - intake air temp.)
• Compressor off temp. = setting temp.+3.0°C
on temp. = setting temp.
• If compressor operates at some operation frequency, the operating frequency of  compressor cannot be
changed within 30 seconds.
• Condition of compressor turned off
- When intake air temperature reaches +3°C above the setting temperature.
• Condition of indoor fan turned off
- While in compressor on:indoor pipe temp. < 26°C
off: indoor pipe temp. < 37°C
• While in defrost control, between the indoor and outdoor fans are turned off.
• Compressor 2minutes delay
- After compressor off, the compressor can restart minimum 2 minutes later.
Temp. differences
over 3.0°C
2.5~3.0°C
2.0~2.49°C
1.5~1.99°C
1.0~1.49°C
0.5~0.99°C
0.0~0.49°C
Comp. Operating frequency
§
¤ı
¤
¤
¤º
¤Ø
¤
[ The operating freq. step of comp]
[The targeting operating freq. of comp. each model]
Model
LS-J0760NL
LS-J0961NL/NT
LS-L1260NL/NT
LS-J0820NL
LS-L1220NL
Comp. Operating frequency
42
47
56
64
70
78
86
40
56
68
78
90
96
105
43
47
53
64
73
83
90
41
47
56
69
80
88
95
43
47
54
63
69
74
80
¤
¤Ø
¤º
¤
¤
(Fh)
¤ı
§
-17-
7. Fuzzy mode operation
• When any of operation mode is not selected like the moment of the power on or when the unit turned off, the
operation mode is selected.
• When determining the operation mode, the compressor, outdoor fan are off and only the indoor fan is operat-
ed for 15seconds, then an operation mode is selected according to.
Basis of determining operating mode
Outdoor temp.
over 24°C
21~24°C
18~21°C
below 18°C
Operating Mode
Cooling
Healthy Dehumidification
intake air temp. 
25°C …Dehumidification
intake air temp. < 25°C … Heating
Heating
7.1 Fuzzy operation for cooling
• According to the setting temperature selected by Fuzzy rule, the operating frequency of compressor is deter-
mined like cooling mode operation.
• At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temperature at that time.
• When the Fuzzy key(=setting temp. key) is input after the initial setting temperature is selected, the  Fuzzy
key value and intake air temperature at that time are compared to select the setting temperature automatically
according to the fuzzy rule.
• While in Fuzzy operation, the air flow speed of the indoor fan is automatically operated by chaos logic.
at beginning
during opertion
Intake air temp.
over 26°C
18~26°C
below 18°C
18~30°C
below 18°C
over 30°C
Setting temp.
25°C
intake air temp. -05°C 
18°C
Fuzzy rule
18°C Fuzzy rule
30°C Fuzzy rule
Fan speed
CHAOS airflow
-18-
7.2 Fuzzy operation for Heating
• According to the setting temperature selected by Fuzzy rule, the operating frequency of compressor is deter-
mined like heating mode operation.
• At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temperature at that time.
• When the Fuzzy key(=setting temp. key) is input after the initial setting temperature is selected, the Fuzzy key
value and intake air temperature at that time are compared to select the setting temperature automatically
according to the Fuzzy rule.
• While in Fuzzy operation, the airflow speed of the indoor fan is automatically operated by CHAOS logic.
at beginning
during opertion
Outdoor temp.
over 26°C
0~5°C
-5~0°C
below -5°C
16~30°C
below 16°C
over 30°C
Setting temp.
intake air temp. +0.5°C
intake air temp. +1.0°C
intake air temp. +1.5°C
intake air temp. +2.0°C
Fuzzy rule
18°C Fuzzy rule
30°C Fuzzy rule
Fan speed
CHAOS airflow
7.3 Fuzzy operation for dehumidification
• At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temperature at that time.
• According to the setting temperature selected by Fuzzy rule, the operating frequency of compressor is deter-
mined like dehumidefication mode operation.
at beginning
during operation
Outdoor temp.
over 26°C
18~26°C
below 18°C
Setting temp.
25°C
intake air temp. -0.5°C
18°C
same as dehumidification mode
Fan speed
CHAOS airflow
-19-
8. Jet cool mode operation
• While  in heating mode or Fuzzy operation, the Jet Cool key cannot be input. When it is input while in the
other mode operation(cooling, dehumidification, ventilation), the Jet Cool mode is operated.
• In the Jet Cool mode, the indoor fan is operated super-high speed for 30 min. at cooling mode operation.
• In the Jet Cool mode, the room temperature is controlled to the setting temperature, 18°C.
• When the sleep timer mode input while the Jet Cool mode operation, the Jet Cool mode has the priority.
• When the Jet Cool key is input, the upper/lower vane is reset to those of the initial cooling mode and then
operated in order that the air outflow could reach further.
9. Swing mode
9.1 Chaos swing mode of not fuzzy mode operation
• By the Chaos swing key input, the upper/lower vane automatically operates with the Chaos swing or it is fixed
to the desired direction.
Chaos swing of LS-J0760NL, LS-J0901NL/NT, LS-J0820NL
Closed
Open
Mode 1
Mode 2
Mode 3
Mode 4
Mode 5
Mode 6
Mode 7
Beginning
of cooling
Mode 8
< Cooling Mode >
8
°
135
°
< Heating Mode >
Closed
Open
Mode 1
Mode 2
Mode 3
Mode 4
Mode 5
Mode 6
Mode 7
Beginning
of heating
Mode 8
8
°
135
°
Closed
Open
Mode 1
Mode 2
Mode 3
Mode 4
Mode 5
Mode 6
Mode 7
Beginning
of cooling
Mode 8
< Cooling Mode >
7
°
125
°
< Heating Mode >
Closed
Open
Mode 1
Mode 2
Mode 3
Mode 4
Mode 5
Mode 6
Mode 7
Beginning
of heating
Mode 8
7
°
125
°
Chaos swing of LS-L1260NL/NT, LS-L1220NL
Page of 74
Display