DOWNLOAD LG LS-H096PDC0 Service Manual ↓ Size: 7.18 MB | Pages: 61 in PDF or view online for FREE

Model
LS-H096PDC0
Pages
61
Size
7.18 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
ls-h096pdc0.zip
Date

LG LS-H096PDC0 Service Manual ▷ View online

4) Sticking the installation guide map and
fixing Indoor unit
5) Preparing work for installation
1. Drill a hole in the wall
• Drill the piping hole with a ø50mm hole core drill.
Drill the piping hole at either the right or the left with
the hole slightly slanted to the outdoor side.
-21-
Plastic anchors
INSTALLATION GUIDE MAP
10mm
INST
ALLA
TION GU
INST
AIIA
TION GUIDE MAP
INST
ALLA
TION GUIDE MAP
1. Put an Installation Guide Map on the desired 
    surface.
2. Make a hole with diameter of 6mm and depth of 
    30-35mm when piercing a screw point.
3. Drive the fore plastic anchors into drilled points.
4. Hang the hole of product at the upper screws. 
    (In this time, Remove the map)
     (Falling attention)
5. Check the fixed product with light power.
6. Look at suited horizon by horizontal meter on 
    the horizontal setting line, and Fix lightly the 
    map by adhesive tape.
7. Drill the piercing part for connecting pipe as 
    diameter 50mm. (In case of piercing rear surface)
Refer to No. 5 on this page when making a hole in the wall.
8. First, Drive the two points of the upper parts by 
    screws. (Leave 10mm for hanging product)
9. Drive the lower parts after facing the hole of 
    product with plastic anchors, and fix completely 
    the upper screws.
In case of nothing wrong in the matter,
connect the pipe and the wire. 
(Installation manual reference)
Horizontality
INST
ALLA
TION GUIDE MAP
Plastic anchors
INST
ALLA
TION GUIDE MAP
Hanger hole
(Rear side of 
product)
5-7mm
(0.2~0.3")
Indoor
WALL
Outdoor
-22-
2. Flaring Work and Connection of Piping
1) Flaring work
Main cause for refrigerant leakage is due to defect in
the flaring work. Carry out correct flaring work using the
following procedure.
1. Cut the pipes and the cable.
• Use the piping kit accessory or pipes purchased locally.
• Measure the distance between the indoor and the 
outdoor unit.
• Cut the pipes a little longer than the measured 
distance.
• Cut the cable 1.5m longer than the pipe length.
2. Burr removal
• Completely remove all burrs from the cut cross sec-
tion of pipe/tube.
• Put the end of the copper tube/pipe in a downward
direction as you remove burrs in order to avoid drop-
ping burrs into the tubing.
3. Putting nut on
• Remove flare nuts attached to indoor and outdoor
unit, then put them on pipe/tube having completed
burr removal.
(not possible to put them on after flaring work)
4. Flaring work
• Firmly hold copper pipe in a die in the dimension
shown in the table above.
• Carry out flaring work using flaring tool as shown
below.
5. Check
• Compare the flared work with figure below.
• If flare is noted to be defective, cut off the flared sec-
tion and re-flare it.
Copper
pipe
90
°
Slanted   Uneven  Rough
Bar
Copper pipe
Clamp handle
Red arrow mark
Cone
Yoke
Handle
Bar
"A"
Inclined
Inside is shiny without scratches
Smooth all round
Even length
all round
Surface
damaged
Cracked Uneven
thickness
= Improper flaring =
Pipe
Reamer
Point down
Flare nut
Copper tube
mm
inch
mm
Ø6.35
1/4
0~0.5
Ø9.52
3.8
0~0.5
Ø12.7
1/2
0~0.5
Ø15.88
5/8
0~1.0
Ø19.05
3/4
1.0~1.3
Outside diameter
2) Connection of piping Indoor
• Preparing the indoor unit's piping and drain hose for
installation through the wall.
1. Route the indoor tubing and the drain hose in the
direction of rear left or right.
2. Tape the tubing, drain hose, and the connecting
cable. Be sure that the drain hose is located at the
lowest side of the bundle. Locating at the upper
side can cause drain pan to overflow inside the
unit.
NOTE: If the drain hose is routed inside the room, 
insulate the hose with an insulation material* so that
dripping from "sweating"(condensation) will not damage
furniture or floors.
*Foamed polyethylene or equivalent is recommended.
3. Connecting the pipings to the indoor unit and drain
hose to drain pipe.
• Align the center of the pipes and sufficiently tighten
the flare nut by hand.
• Tighten the flare nut with a wrench.
• When extending the drain hose at the indoor unit,
install the drain pipe.
4. Wrap the insulation material around the connecting
portion.
• Overlap the connection pipe insulation material and
the indoor unit pipe insulation material. Bind them
together with vinyl tape so that there is no gap.
-23-
Connecting
cable
Gas side piping
Liquid side piping
Drain hose
Loop
Indoor unit tubing
Flare nut
Pipes
Wrench
Indoor unit tubing
Open-end wrench (fixed)
Connection pipe
Flare nut
GAS
LIQUID
Capacity
(Btu/h)
Refrigerant
7K, 8K, 9K
3/8"[4.2kg.m]
1/4"[1.8kg.m]
R-22
11K, 12K, 14K
1/2"[5.5kg.m]
1/4"[1.8kg.m]
7K~14K
3/8"[4.2kg.m]
1/4"[1.8kg.m]
R-410A
Pipe Size[Torque]
Vinyl tape(narrow)
Adhesive
Drain pipe
Indoor unit drain hose
Plastic bands
Insulation material
-24-
• Wrap the area which accommodates the rear piping
housing section with vinyl tape.
• Bundle the piping and drain hose together by wrap-
ping them with vinyl tape for enough to cover where
they fit into the rear piping housing section.
3) Connection of the pipes-Outdoor
1. Align the center of the pipings and sufficiently
tighten the flare nut by hand.
2. Finally, tighten the flare nut with torque wrench
until the wrench clicks.
• When tightening the flare nut with torque wrench,
ensure the direction for tightening follows the arrow on
the wrench.
Vinyl tape(narrow)
Connection
pipe
Connecting cable
Vinyl tape
(wide)
Wrap with vinyl tape
Indoor 
unit pipe
Pipe
Wrap with vinyl tape
Drain hose
Pipe
Vinyl tape(wide)
Outdoor unit 
Liquid side piping
(Smaller diameter)
Gas side
piping
(Bigger
diameter)
Torque wrench
Outdoor unit 
Gas side piping
(Bigger diameter)
Liquid side
piping
(Smaller
diameter)
Torque wrench
GAS
LIQUID
Capacity
(Btu/h)
Refrigerant
7K, 8K, 9K
3/8"[4.2kg.m]
1/4"[1.8kg.m]
R-22
11K, 12K, 14K
1/2"[5.5kg.m]
1/4"[1.8kg.m]
7K~14K
3/8"[4.2kg.m]
1/4"[1.8kg.m]
R-410A
Pipe Size[Torque]
Page of 61
Display

Click on the first or last page to see other LS-H096PDC0 service manuals if exist.