—29—
• Unhook the tab on the left inside edge of the
chassis by pressing it outwards and at the same
time, slightly pull the evaporator until the tab is
clear of the end-plate.
• Remove the evaporator from the chassis
carefully. 
• Unhook the tab on the right inside of the chassis
at the same time, slightly pull the evaporator
toward you until the tab is clear of the slot. 
5. To remove the Cross-Flow Fan. 
• Loosen the screw securing the cross-flow fan to
the fan motor (do not remove).
• Pull the left end of the cross-flow fan with the
self-aligning bearing out the groove. 
• Remove the cross-flow fan by sliding it out from
the shaft of fan motor. 
6. To remove the Fan Motor. 
• Pick it up from the groove. (Do not remove a
black rubber as a spacer).
INSTALLATION INSTRUCTIONS
SINGLE SPLIT WALL MOUNTED TYPE AIR CONDITIONER
1. Type "A" screw
2. Installation Plate
3. Type "B" screw
4. Holder Remote Control
Air filter
Gas side piping
Liguid side piping
Additional drain pipe
Vinyl tape (Narrow)
Connecting cable
• Cooling & Heat pump : 22A
• Cooling only
: 12A
(Left and right
are identical)
More than
10cm
More than
10cm
More than
10cm
More than
60cm
Installation plate
Sleeve
Bushing-Sleeve
Putty(Gum Type Sealer)
Bend the pipe as closely 
on the wall as possible, 
but be careful that it 
doesn't break.
Installation parts you 
must purchase 
Vinyl tape (Wide)
   Apply after carrying out a
   drainage test.
   To carry out the drainage 
   test, remove the air filters
  and pour water into the heat 
  exchanger.
Saddle
More than
5cm
More than
5cm
More than 70cm
P/No. : 3828A30087D
• Please read this instruction sheet completely before installing the product.
• When the power cord is damaged, replacement work shall be performed by authorized
personnel only.
• Installation work must be performed in accordance with the national wiring standards by
authorized personnel only.
Installation Parts Provided
• This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
ENGLISH
ITALIANO
ESPAÑOL
FRANÇAIS
DEUTSCH
10
Connection of the
pipes-Outdoor
Align the center of the pipings and
sufficiently tighten the flare nut by hand.
Finally, tighten the flare nut with torque
wrench until the wrench clicks.
When tightening the flare nut with torque
wrench, ensure the direction for tightening
follows the arrow on the wrench.
A
B
Outdoor unit 
Torque
wrench
Reroute the pipings and the drain hose across
the back of the chassis.
H
Indoor unit installation 
Remove the spacer.
Ensure that the hooks are properly seated on the
installation plate by moving it left and right.
I
Drain hose
Connecting
cable
Piping for
passage through
piping hole
Drain hose
Vinyl tape(narrow)
Pipe
Wrap with 
vinyl tape(wide)
Bundle the piping and drain hose together by
wrapping them with cloth tape over the range
within which they fit into the rear piping housing
section.
Press the lower left and right sides of the unit against
the installation plate until the hooks engage into their
slots(clicking sound).
3/8"[4.2kg.m]
1/4"[1.8kg.m]
Pipe Size[Torque]
GAS
LIQUID
ENGLISH
11
Connect the cable to the
Indoor unit.
Connect the cable to the indoor unit by
connecting the wires to the terminals on the
control board individually according to the
outdoor unit connection.
(Ensure that the color of the wires of the
outdoor  unit and the terminal No. are the same
as those of the indoor unit.)
CAUTION
The power cord connected to the indoor unit should
be complied with the following specifications
(Type H05VV-F approved by HAR or SAA).
1(L)
Terminals on the outdoor unit
Terminals on the indoor unit
1(L)
2(N)
2(N)
BROWN
BLUE GREEN/YELLOW
BROWN
BLUE GREEN/YELLOW
Terminals on the outdoor unit
Terminals on the indoor unit
1(L)
1(L)
2(N)
2(N)
3
4
3
4
BROWN BLUE
G/Y
BLACK
RED
BROWN BLUE
G/Y
RED
BROWN BLUE
BLACK
BLACK
G/Y
RED
RED
G/Y
BLUE
BROWN
NORMAL
CROSS-SECTIONAL
AREA 1.0mm
2
 
NORMAL
CROSS-SECTIONAL
AREA 1.0mm
2
 
The connecting cable connected to the indoor and
outdoor unit should be complied with the following
specifications
(Type H07RN-F approved by HAR or SAA).
• Cooling model
CONNECTING THE CABLE BETWEEN INDOOR UNIT AND OUTDOOR UNIT
• Heat pump model
Color of Wires
Color of Wires
Color of Wires
Color of Wires
Air 
Conditioner
Main power source
If a power plug is not to be used, provide a circuit breaker between power source and the unit as shown below.
Circuit Breaker
Use a circuit
breaker or time
delay fuse.
CAUTION
Page of 81