LG LS-H0560AL_BL Service Manual ▷ View online
Wiring Diagram
(1) Indoor Unit
(2) Outdoor Unit
—8—
3854A30077H
INDOOR WIRING DIAGRAM
CN-DISP1
FUSE
AC250V/T2A
CN-TH1
TRIAC
SH-CAPA.
BL/RIBBED
BR/PLAIN
GN/YL
BR
YL
OR
BK
CN-TAB1
CN-MOTOR
CN-TAB2
RY-COMP.
ZNR
THERMISTOR
FORCED
OPERATION
OPERATION
TEST
OPERATION
OPERATION
REMOTE
CONTROL
CONTROL
MOTOR
MAIN PCB
ASM
DISPLAY PCB ASM
POWER
TO OUTDOOR UNIT
PILLAR
TERMINAL
TERMINAL
BR
BL
GN/YL
BR
BL
GN/YL
1(L) 2(N)
3
4
BL
CN-U/D
STEP
MOTOR
TO INDOOR UNIT
BLACK
PILLAR
TERMINAL
TERMINAL
BR
BR(YL)
OLP
1
COMP
RD
BL
BL
YL
FAN
MOTOR
MOTOR
GN/YL
RD
BL
CAPACITOR
H
C
F
R
C
S
BR
BL GN/YL
BR
BL GN/YL
1
(
L
)
2
(
N
)
3854AR2262F
OUTDOOR WIRING DIAGRAM
Operation Details
(1) The function of main control
1. Time Delay Safety Control
• 3min.; The compressor operation is delayed for 3 minutes to balance the pressure of cycle.
(Protection of compressor)
• 5sec.; The indoor fan is delayed for 5 seconds, when operating initially, to prevent noises occurred by the vertical
louver and wind.
2. Airflow Direction Control
• This function is to swing the vertical louver up and down automatically and to set it at a fixed position.
• The procedure is as the following.
1st ; Press the ON/OFF Button to operate the unit.
2nd ; Press the Airflow Direction Control Button to swing the vertical louver up and down automatically.
3nd ; Repress the Airflow Direction Control Button to set the vertical louver at a fixed position.
3. Cooling Mode Operation
• When selecting the Cooling(
) Mode Operation, the unit will operate according to the setting by the
remote controller and the operation diagram is shown below.
CLOSED
8
7
6
5
4
3
2
1
OPEN
Setting point:
8°
108°
INTAKE AIR TEMP.
SETTING TEMP. +0.5
°
C
(Compressor ON)
SETTING TEMP. -0.5
°
C
(Compressor OFF)
More than
3 minutes
More than
3 minutes
INDOOR FAN SPEED
COMPRESSOR
Selecting
fan speed
fan speed
Selecting
fan speed
fan speed
Selecting
fan speed
fan speed
Low
ON
OFF
ON
ON
OFF
Low
—9—
—10—
5. Forced operation
• If you lose wireless remote controller, you can operate the unit with forced operation switch.
• The standand conditions are as following.
• The standand conditions are as following.
Cooling Model
Operation Mode
Cooling
Indoor FAN Speed
High
Setting temp.
22°C
4. Soft Dry Operation Mode
• During Soft Dry Operation, the compressor ON temperature is the setting temperature plus 1°C, the compres-
sor OFF temperature is the setting temperature minus 0.5°C.
• When the room temperature rises over the compressor ON temperature, the operation mode is switched to
the Cooling operation.
• When the room temperature falls between the compressor ON temperature and OFF temperature, the opera-
tion mode is switched to the Soft Dry Operation.
• The operation diagram is shown below.
INDOOR FAN
LOW
Selecting
fan speed
ON
ON
ON
OFF
OFF
Operation
Cooling
Dry Operation
COMPRESSOR
SETTING TEMP.+1
°
C
(COMP. ON)
SETTING TEMP.-0.5
°
C
(COMP. OFF)
10 minutes
2 minutes
58 seconds
2 minutes
58 seconds
maximum
10 minutes
maximum
4 minutes
4 minutes
—11—
Display Function
• Lights up during cooling operation.
• Lights up during soft dry operation.
• Lights up during timer operation.
Cooling Indicator
Soft Dry Indicator
Timer Indicator