DOWNLOAD LG LS-H0560AL_BL Service Manual ↓ Size: 2.04 MB | Pages: 58 in PDF or view online for FREE

Model
LS-H0560AL_BL
Pages
58
Size
2.04 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
ls-h0560al-bl.zip
Date

LG LS-H0560AL_BL Service Manual ▷ View online

—4—
Name and Function-Remote Controller
TEMP.
TIME
OFF
hr.
4
2
5
1
6
3
7
Remote Controller
Signal transmitter
Transmits the signals to the room
air conditioner.
OPERATION DISPLAY
Displays the operation conditions.
AIRFLOW DIRECTION START/STOP BUTTON
Used to stop or start louver movement and set the
desired up/down airflow direction.
OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
OFF TIMER BUTTON
Used to set the time of stopping operation.
START/STOP BUTTON
Operation starts when this button is pressed, and
stops when the button is pressed again.
ROOM TEMPERATURE SETTING BUTTONS
INDOOR FAN SPEED SELECTION BUTTON
1
2
3
4
5
6
7
—5—
Product Specifications 
Model Name
Item                         Unit
Cooling Capacity
BTU/h(kcal/h)
5,500(1,386)
5,500(1,386)
Moisture Removal
/h
0.7
0.7
Power Source
Ø, V, Hz
1Ø, 220-240V, 50Hz
1Ø, 220-240V, 50Hz
Indoor
4.2
4.2
Outdoor
15
15
Indoor
35
35
Outdoor
46 46
Input
W
550
560
Running Current
A
2.5
2.5
E.E.R.
BTU/h-W
10.0
10.0
Indoor 5
5
Outdoor
14
14
Indoor
670 x 250 x 156
670 x 250 x 156
Outdoor
525 x 564x 265
525 x 564x 265
Indoor
6
6
Outdoor
20
20
Refrigerant (R-22)
g
500
560
Liquid
1/4" (6.35)
1/4" (6.35)
Gas
3/8" (9.52)
3/8" (9.52)
Timer Operation
7 hours
7 hours
Drain Hose
O
O
Connecting Cable
1.0mm
2
1.0mm
2
Power Cord
1.0mm
2
1.0mm
2
Air Circulation
Noise Level
m
3
/min
dB (A)±3
Service Valve
Motor Output
Dimensions(W
H
D)
Net. Weight
W
mm
kg
LS-H0560CL
LS-M0561AL
LS-M0561DL
NOTE: Please refer to Label Quality on the product since this specification may be changed for improving 
performance
—6—
Dimensions
(1) Indoor Unit 
(2) Outdoor Unit
Tubing hole cover
Air Inlet
Cooled Air Outlet
Tubing hole cover
Tubing hole cover
Liquid side
2-way valve
Gas side
3-way valve
—7—
Pipe size(Diameter: Ø)
Max.
Max.
MODEL
Piping length
Elevation
Gas
Liquid
(m)
(m)
ALL MODELS
3/8"
1/4"
7
5
INDOOR UNIT
OUTDOOR UNIT
HEAT
EXCHANGE
(EVAPORATOR)
HEAT
EXCHANGE
(CONDENSER)
COMPRESSOR
ACCUMU
LATOR
GAS SIDE
3-WAY VALVE
LIQUID SIDE
2-WAY VALVE
CAPILLARY TUBE
COOLING
HEATING
REVERSING
VALVE
Refrigeration Cycle Diagram
Page of 58
Display

Click on the first or last page to see other LS-H0560AL_BL service manuals if exist.