1) Connection of power supply 
1. Connect the power supply cord to independent
power supply.
• Circuitbreaker is required.
2. Prepare the remote control.
• Insert two batteries provided. 
Remove the cover from the back of the remote
control.
• Slide the cover according to the arrow direction.
Insert the two batteries.
(Two “R03” or “AAA” dry-cell batteries or equiva-
lent.) 
• Be sure that the (+) and (-) directions are cor-
rect.
• Be sure that both batteries are new. 
Re-attach the cover. 
• Slide it back into position. 
3. Operate the unit for fifteen minutes or more.  
• Anchor the outdoor unit with a bolt and nut (ø10cm)
tightly and horizontally on a concrete or rigid mount.
• When installing on the wall, roof or rooftop, anchor
the mounting base securely with a nail or wire
assuming the influence of wind and earthquake. 
• In the case when the vibration of the unit is con-
veyed to the house, settle the unit with an anti-
vibration rubber. 
2)  Evaluation of the performance 
1. Measure the temperature of the intake and discharge
air. 
2.  Ensure the difference between the intake tempera-
ture and the discharge one is more than 8°C (Cool-
ing) or reversely (Heating).
Bolt
Tubing
connection
discharge air
6. Test running 
Settlement of Outdoor Unit 
CAUTION: This appliance must be installed in accordance with current National Wiring Regulations.
Connecting cable between indoor unit and outdoor unit shall be approved and the size of con-
ductor shall be in accordance with local law.
(Cooling)
2) Indoor unit Installation
The mounting wall should be strong and solid enough to
prevent it from the vibration. 
1. Mount the installation plate on the wall with
four Type "A" screws.
(if mounting the unit on the concrete wall, consider
using anchor bolts.)
• Always mount the installation plate horizontally
by aligning the marking-off line by means of the
thread and a level. 
2. Drill the piping hole with 70mm dia. holecore
drill.                 
• For right rear piping, draw a line in the direction
of the arrow marked “A” and make another line
extended from the bottom line of installation
plate. The meeting point of two lines is the cen-
ter of the hole.
• For left rear piping, draw a line extented left from
the bottom line of the installation plate. This is
the center line of any hole for the left rear instal-
lation.
•  Drill the Piping hole at either the right or the left
and the hole should be slightly slant to the out-
door side. 
Installation Plate
Thread
Marking-off line
Weight
Type “A” screw
Wall
Left rear piping
Right rear piping
ø70mm
“A”
5~7mm
Indoor
Outdoor
Center line
Hole Center
Installation plate
The lower left and right side of installa-
tion Plate
ƒ¡
29
ƒ¡
1)  PREPARATION OF PIPINGS
1.  Cut the pipes and the cable.                     
Use the accessory piping kit or the pipes pur-
chased locally.
•  Measure the distance between the indoor and
the outdoor unit.
•  Cut the pipes a little longer than measured dis-
tance.
Cut the cable 1.5m longer than the length of
pipe. 
2.  Remove burrs. 
• Remove burrs from cut edges of pipes.
•  Turn the pipe end toward down to avoid the met-
al powder entering the pipe. 
Caution :                                                     
If burrs are not removed, they may cause a gas leakage.  
3. Flaring the pipes.                                     
• Insert the flare nuts, mounted on the connection
ports of both indoor and outdoor unit, onto the
copper pipes. Some gas may leak, when the
flare nuts are removed from the indoor unit, as
some gas is charged to prevent the inside of the
pipe from rusting. 
•  Fit the copper pipe end into the Bar of flare tool
about 0.5~1.0mm higher. (See illustration.)
• Flare the pipe ends. 
4. Tape the flaring portion to protect it from the
dust or damages. 
90°
Pipe cutter
Slanted  Rough
Pipe
Reamer
Point down
A
Bar
Copper pipe
Handle
Cone
Bar
Yoke
Inclined
Surface
damaged
Cracked Uneven
thickness
= Improper flaring =
2. Piping and Drainage of indoor unit 
ƒ¡
30
ƒ¡
When properly flared, the internal surface of the flare
will evenly shine and be of even thickness.
After the flare part comes into contact with the connec-
tors, carefully check the flare finish. 
"A"; ø15.88mm(
5
/
8
")
¤A
0.5mm
ø12.7mm(
1
/
2
")
¤A
0.5mm
ø9.52mm(
3
/
8
")
¤A
0.5mm
ø6.35mm(
1
/
4
")
¤A
1.0mm
2)  Connection of Pipings  
1. Remove the indoor tubing with Drain hose from
the hole.
• Remove tubing holder and pull the tubing out of
the chassis.
2. Replace the tubing holder into original position.
3. Route the tubing and the drain hose straight
backwards. 
4. Insert the connecting cable into the indoor unit
through the piping hole.                          
• Do not connect the cable to the indoor unit.
•  Make a small loop with the cable for easy con-
nection later.  
5. Tape the tubing, drain hose and the connecting
cable. Be sure that drain hose locates at the
lowest side of the bundle. Locating at the upper
side can be a reason that drain water overflows
drain pan inside the unit.
ƒ¡
31
ƒ¡
For right rear piping 
Tubing holder
Press
1
Pull
2
Gas side piping
Liquid side piping
Drain hose
Connecting
cable
Taping
Indoor/Outdoor
Connecting cable
To remove the holder,
press the bottom of chas-
sis near the holder upward
and pull the tab out of its
hole.