DOWNLOAD LG LS-C322MLD0_MMB0_MMM0 / LS-H322MLD0_MMB0_MMM0 / LS-C366NLD0_NMM0 / LS-H366NLB0_NLD0_NMM0 / S36LHP Service Manual ↓ Size: 6.27 MB | Pages: 95 in PDF or view online for FREE

Model
LS-C322MLD0_MMB0_MMM0 LS-H322MLD0_MMB0_MMM0 LS-C366NLD0_NMM0 LS-H366NLB0_NLD0_NMM0 S36LHP
Pages
95
Size
6.27 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
ls-c322mld0-mmb0-mmm0-ls-h322mld0-mmb0-mmm0-ls-c36.zip
Date

LG LS-C322MLD0_MMB0_MMM0 / LS-H322MLD0_MMB0_MMM0 / LS-C366NLD0_NMM0 / LS-H366NLB0_NLD0_NMM0 / S36LHP Service Manual ▷ View online

- 13 -
LS-C366NLD0/LS-H366NLD0/LS-H366NLB0/
LS-C366NMM0/LS-H366NMM0
LS-H366NLD0/LS-H366NLB0/
LS-H366NMM0
LS-C366NLD0/LS-C366NMM0
MOTOR
SH-CAPA.
YL
PILLAR
TERMINAL
AUTO RESTART
FORCED OPERATION
CN-DISP
CN-L/R
CN-U/D
CN-TH
THERMISTOR
STEP
MOTOR
(UP/DOWN)
STEP
MOTOR
(L/R)
H.V.B ASM
LIMITS S/W
Negative ion
OPTION
STEP
MOTOR
(L/R)
CN-L/R
DISPLAY PCB ASM
INDOOR WIRING DIAGRAM
3854A20065A
TO OUTDOOR UNIT
BL
3(L) 4(N) 5
BR
RD
GN/YL
BL
RD
BR
GN/YL
BR
FUSE
AC250V/T2A
TRIAC
OR
BK
ZNR
CN-POWER
CN-MOTOR
5
3(L)
4(N)
BK
RD
WH
WH
WH
R
S
COMP
RUNNING
CAPACITOR
BL
BL
BR
BR
BK
BK
BK
BK
WH
1(L)
2(N)
TERMINAL BLOCK
1
2
CN-P2(N)
CN-COMP2
CN-FAN
OR
OR
OR
FAN1
OUTDOOR PCB
PTCR
MAGNECTIC
CONTACTOR
CAPACITOR
YL
YL
CN-
P1(L)
CN-
COMM
RD
BK
BK
BK
BK
BK
BK
TERMINAL BLOCK1
TO INDOOR UNIT
POWER INPUT
FUSE(5A)
FUSE(5A)
T2
T1
L2
L1
A2
A1
BR
C
OUTDOOR WIRING DIAGRAM
3854A20051H
YL
FAN2
CAPACITOR1
CAPACITOR2
OR
YL
OR
5
3(L)
4(N)
BK
RD
WH
WH
WH
R
S
COMP
RUNNING
CAPACITOR
BL
BL
BR
BR
BK
BK
BK
BK
WH
1(L)
2(N)
TERMINAL BLOCK
1
2
CN-P2(N)
CN-COMP2
CN-FAN
CN-4WAY
CN-TH
THERMISTOR
OR
OR
OR
OR
FAN1
OUTDOOR PCB
PTCR
MAGNECTIC
CONTACTOR
CRANK CASE
HEATER FOR COMP
CAPACITOR
YL
YL
CN-
P1(L)
CN-
COMM
RD
BK
BK
BK
BK
BK
BK
BK
BK
BK
TERMINAL BLOCK1
TO INDOOR UNIT
POWER INPUT
FUSE(5A)
FUSE(5A)
T2
T1
L2
L1
A2
A1
BR
C
OUTDOOR WIRING DIAGRAM
3854A20051K
YL
FAN2
CAPACITOR1
CAPACITOR2
OR
YL
OR
REVERSING
VALVE
HIGH PRESS
SWITCH
(2) Outdoor Unit
• 36K, 38K
(1) Indoor Unit
1. MAIN UNIT FUNCTION
• DISPLAY
1) C/O Model (high quality LCD remote controller supplied)
Operation Indicator
• On while in appliance operation, off while in appliance pause
Timer Indicator
• On while in timer mode (on/off) and in sleep timer mode, off when timer mode is completed or canceled.
Comp. Running Indicator
• While in appliance operation, on while in outdoor unit compressor running, off while in compressor off
Plasma Indicator
• On while in plasma mode, off while plasma mode is canceled.
Auto restart Indicator
• On while auto restart mode, off while auto restart mode is canceled.
Auto restart
• In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate
procedures automatically to the previous operating conditions.
If your want to use this operation, press the Auto Restart Button.
Power(Forced Operation)
• Operation starts, when this button is pressed and stops when you press the button again.
2) H/P Model (high quality LCD remote controller supplied)
Operation Indicator
• On while in appliance operation, off while in appliance pause
Timer Indicator
• On while in timer mode (on/off) and in sleep timer mode, off when timer mode is completed or canceled
Defrost Indicator
• Off except when hot start during heating mode operation or while in defrost control.
Plasma Indicator
• On while in plasma mode, off while plasma mode is canceled.
Auto restart Indicator
• On while auto restart mode, off while auto restart mode is canceled.
Auto restart
• In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate
procedures automatically to the previous operating conditions.
If your want to use this operation, press the Auto Restart Button.
Power(Forced Operation)
• Operation starts, when this button is pressed and stops when you press the button again.
■ Cooling Mode Operation
• When the intake air temperature reaches 0.5°C below the setting temp, the compressor and the outdoor fan stop.  
• When it reaches 0.5°C above the setting temp, they start to operate again.
Compressor ON Temp=> Setting Temp+0.5°C
Compressor OFF Temp => Setting Temp-0.5°C
• While in compressor running, operating with the airflow speed set by the remote controller. While in compressor
not running, operating with the low airflow speed regardless of the setting.
- 14 -
Operation Details
■ Healthy Dehumidification Mode
• When the dehumidification operation input by the remote controller is received, the intake air temperature is
detected and the setting temp is automatically set according to the intake air temperature.
26°C 
≤ Intake Air Temp              => 25°C
24°C 
≤ Intake Air Temp < 26°C => Intake Air Temp-1°C
18°C 
≤ Intake Air Temp < 24°C => Intake Air Temp-0.5°C
Intake Air Temp < 18°C                   => 18°C
• While in compressor off, the indoor fan repeats low airflow speed and pause.
• While the intake air temp is between compressor on temp. and compressor off temp., 10-min dehumidification
operation and 4-min compressor off repeat
Compressor ON Temp.  => Setting Temp+0.5°C
Compressor OFF Temp.  => Setting Temp-0.5°C
• In 10-min dehumidification operation, the indoor fan operates with the low airflow speed.
■ Heating Mode Operation
• When the intake air temp reaches +3°Cabove the setting temp, the compressor is turned off.  When below the
setting temp, the compressor is turned on.
Compressor ON Temp. => Setting Temp.
Compressor OFF Temp. => Setting Temp.+3°C 
• While in compressor on, the indoor fan is off when the indoor pipe temp. is below 26®¨C , when above 28°C , it
operates with the low or setting airflow speed (while in sleep mode, with the medium airflow speed).
• While in compressor off, the indoor fan is off when the indoor pipe temp is below 33°C , when above 35°C , it
operates with the low airflow speed.
• If overloaded while in heating mode operation, in order to prevent the compressor from OLP operation, the out-
door fan is turned on/off according to the indoor pipe temp.
• While in defrost control, both of the indoor and outdoor fans are turned off.
■ Defrost Control
• While in heating mode operation in order to protect the evaporator pipe of outdoor unit from freezing, reversed
to cooling cycle to defrost the evaporator pipe of the outdoor unit.
• Defrost control is available 30 minutes later since heating mode operation started, and it will not polong over 6
minutes.
• Deicing starts only when the outdoor pipe temperature falls below -6°C after 30 minutes passed from starting of
heating operating and more than 10 minutes operation of compressor.
• Deicing ends after 6 minutes passed from starting of deice operation or when the outdoor pipe temperature rises
over 12°C even if before 6 minutes.
■ Fuzzy Operation (C/O Model)
• According to the temperature set by Fuzzy rule, when the intake air temp is 0.5°C or more below the setting
temp, the compressor is turned off.  When 0.5°C or more above the setting temp, the compressor is turned on.
Compressor ON Temp  => Setting Temp+0.5°C
Compressor OFF Temp => Setting Temp+0.5°C
• At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temp at that time.
- 15 -
26°C 
≤ Intake Air Temp           => 25°C
24°C 
≤ Intake Air Temp<26°C => Intake Air Temp+1°C
22°C 
≤ Intake Air Temp<24°C => Intake Air Temp+0.5°C
18°C 
≤ Intake Air Temp<22°C => Intake Air Temp
Intake Air Temp<18°C               => 18°C
• When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature
automatically according to the Fuzzy rule.
• While in Fuzzy operation, the airflow speed of the indoor fan is automatically selected according to the tempera-
ture
■ Fuzzy Operation (H/P Model)
• When any of operation mode is not selected like the moment of the power on or when 3 hrs has passed since
the operation off, the operation mode is selected.
• When determining the operation mode, the compressor, the outdoor fan, and the 4 way valve are off and only
the indoor fan is operated for 15 seconds.  Then an operation mode is selected according to the intake air temp
at that moment as follows.
24°C 
≤ Inatake Air Temp           => Fuzzy Operation for Cooling
21°C 
≤ Inatake Air Temp<24°C => Fuzzy Operation for Dehumidification
Inatake Air Temp<21°C               => Fuzzy Operation for Heating
• If any of the operation modes among cooling / dehumidification / heating mode operations is carried out for 10
sec or longer before Fuzzy operation, the mode before Fuzzy operation is operated.
1) Fuzzy Operation for Cooling
• According to the setting temperature selected by Fuzzy rule, when the intake air temp is 0.5°C or more below
the setting temp, the compressor is turned off.  When 0.5°C or more above the setting temp, the compressor is
turned on.
Compressor ON Temp   => Setting Temp+0.5°C
Compressor OFF Temp => Setting Temp+0.5°C
• At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temp at that time.
26°C 
≤ Intake Air Temp           => 25°C
24°C 
≤ Intake Air Temp<26°C => Intake Air Temp+1°C
22°C 
≤ Intake Air Temp<24°C => Intake Air Temp+0.5°C
18°C 
≤ Intake Air Temp<22°C => Intake Air Temp
Intake Air Temp < 18°C               => 18°C
• When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature
automatically according to the Fuzzy rule.
• While in Fuzzy operation, the airflow speed of the indoor fan is automatically selected according to the temperature.
2) Fuzzy Operation for Dehumidification
• According to the setting temperature selected by Fuzzy rule, when the intake air temp is 0.5°C or more below
the setting temp, the compressor is turned off.  When 0.5°C or more above the setting temp, the compressor is
turned on.
- 16 -
Page of 95
Display

Click on the first or last page to see other LS-C322MLD0_MMB0_MMM0 / LS-H322MLD0_MMB0_MMM0 / LS-C366NLD0_NMM0 / LS-H366NLB0_NLD0_NMM0 / S36LHP service manuals if exist.