DOWNLOAD LG LP-E5082HL Service Manual ↓ Size: 3.95 MB | Pages: 127 in PDF or view online for FREE

Model
LP-E5082HL
Pages
127
Size
3.95 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
lp-e5082hl.zip
Date

LG LP-E5082HL Service Manual ▷ View online

– 7 –
POWER SUPPLY
Ø, V, Hz
3, 220/380, 60
3, 220/380, 60
3, 220/380, 60
COOLING CAPACITY
Btu/hr
46,000
71,400
71,400
HEATING CAPACITY
Btu/hr
50,000
-
74,000
(Incl. elec. Heater)
+(3kw)
POWER INPUT
COOLING
W
6,000
9,500
9,500
HEATING
W
5,000
-
8,500
RUNNING 
COOLING
A
18
16
17.0
CURRENT
HEATING
A
17
-
16.0
MODEL
CRNQ-0501-ES8
QR90K1-EW8
MAKER
COPELAND
COPELAND
TYPE
RECIPRO
UNDECIDED
RECIPRO
COMPRESSOR
CAPACITY
Btu/hr
61,500
91,300
INPUT
(KW)
6.21
9.5
LRA
A
65
91.1
NOISE LEVEL
INDOOR
dB(A)
55
63
63
OUTDOOR
dB(A)
65
68
68
AIR 
INDOOR
CFM/CMM
1,554/ 38
1,907/ 54
1,907/ 54
CIRCULATION
OUTDOOR
CFM/CMM
2,825/ 85
5,297/ 150
5,297/ 150
REFRIGERANT (R-22)
OZ(kg)
125 (3.5)
267,8(7.6)
267,8(7.6)
HEAT
INDOOR
R/C/FPI
3/ 28/ 15
3/ 33/ 17
3/ 33/ 17
EXCHANGER
OUTDOOR
R/C/FPI
2/ 36/ 19
2/ 16/ 17(2EA),  2/ 18/ 17(2EA)
2/ 18/ 17(2EA),  2/ 16/ 17(2EA)
FAN
INDOOR
TYPE
SIROCO
OUTDOOR
TYPE
PROPELLER
ROOM TEMPERATURE CONTROL
MICOM CONTROL
WIDTH
23.7/32 (590)
41.2/5 (1,050)
41.2/5 (1,050)
INDOOR
HEIGHT
inch(mm)
71.1/4 (1,810)
74.1/5 (1,880)
74.1/5 (1,880)
DEPTH
17.5/16 (440)
19.1/2(495)
19.1/2(495)
WIDTH
39.3/8 (1000)
52(1,320)
52(1,320)
OUTDOOR
HEIGHT
inch(mm)
38 (965)
39 (990)
39 (990)
DEPTH
14.9/16(370)
25.3/5 (650)
25.3/5 (650)
NET WEIGHT
INDOOR
Ib(kg)
165(75)
186(85)
186(85)
OUTDOOR
Ib(kg)
218(99)
374(170)
374(170)
CONNECTIONS
LIQUID
inch(mm)
3/8(ø 9.52)
5/8 (ø 15.88)
5/8 (ø 15.88)
GAS
inch(mm)
3/4(ø 19.05)
1 (ø 25.4)
1 (ø 25.4)
ITEMS
UNIT
MODEL
LP-E5090HL/(ZL)
LP-E5091HA/(ZA)
LP-F8090CL
LP-F8090HL
D
I
M
E
N
S
I
O
N
S
– 8 –
POWER SUPPLY
Ø, V, Hz
3,380~415, 50
3,380~415, 50
COOLING CAPACITY
Btu/hr
71,400
71,400
HEATING CAPACITY
Btu/hr
-
74,000
(Incl. elec. Heater)
+(8kw)
POWER INPUT
COOLING
W
7,000
7,000
HEATING
W
-
6,500
RUNNING 
COOLING
A
13
13
CURRENT
HEATING
A
-
12.5
MODEL
ZR94KC-TFD
ZR94KC-TFD
MAKER
COPELAND
COPELAND
TYPE
SCROLL
SCROLL
COMPRESSOR
CAPACITY
Btu/hr
78,300
78,300
INPUT
(KW)
6.99
6.99
LRA
A
95
95
NOISE LEVEL
INDOOR
dB(A)
63
63
OUTDOOR
dB(A)
68
68
AIR 
INDOOR
CFM/CMM
1,907/ 54
1,907/ 54
CIRCULATION
OUTDOOR
CFM/CMM
5,297/ 150
5,297/ 150
REFRIGERANT (R-22)
OZ(kg)
267.8/ (    )
267.8/ (7.6)
HEAT
INDOOR
R/C/FPI
3/ 33/ 17
3/ 33/ 17
EXCHANGER
OUTDOOR
R/C/FPI
2/ 16/ 17(2EA),  2/ 18/ 17(2EA)
2/ 18/ 17(2EA),  2/ 16/ 17(2EA)
FAN
INDOOR
TYPE
SIROCO
OUTDOOR
TYPE
PROPELLER
ROOM TEMPERATURE CONTROL
MICOM CONTROL
WIDTH
41.2/5 (1,050)
41.2/5 (1,050)
INDOOR
HEIGHT
inch(mm)
74.1/5 (1,880)
74.1/5 (1,880)
DEPTH
19.1/2 (495)
19.1/2 (495)
WIDTH
52 (1,320)
52 (1,320)
OUTDOOR
HEIGHT
inch(mm)
39 (990)
39 (990)
DEPTH
25 3/5 (650)
25 3/5 (650)
NET WEIGHT
INDOOR
Ib(kg)
186(85)
186(85)
OUTDOOR
Ib(kg)
374(165)
363(165)
CONNECTIONS
LIQUID
inch(mm)
5/8(ø 15.88)
5/8(ø 15.88)
GAS
inch(mm)
1 (ø 25.4)
1 (ø 25.4)
ITEMS
UNIT
MODEL
LP-F8080CL
LP-F8080HL(ZL)
D
I
M
E
N
S
I
O
N
S
– 9 –
1.4 Functions
Indoor Unit
Power Switch ON/OFF
Operation Mode Control
Sensing the room temperature
Controlling the room temperature
Starting Current Control
Sensing Heat Exchanger Temperature
Timer Delay Safety Control
Indoor Fan Speed Control
Operation Indication lamps
Temperature Setting
Airflow Direction Control
Room temperature Display
Timer Control
Sensing Discharge Air Temperature
• Cooling, Soft Dry, Auto, Fan 
¢¡
Cooling Model
• Cooling, Heating, Soft Dry, Fan 
¢¡
Heat Pump Model
• Room temperature sensor (Thermistor)
• Maintains the room temperature in accordance with the setting temperature.
• Indoor fan is delayed for 3 sec at the starting.
• Heat exchanger temperature sensor (Thermistor)
• Restarting is inhibited for approx. 3 minutes.
• High, Med, Low 
¢¡
3HP, 5HP
• High, Low 
¢¡
8HP
• Up : up to 30°C
• Down : down to 16°C 
• Airflow direction Automatic and Manual control
• Low, 10° ~ 35°C, Hi
• Off Timer (1, 2, 3....7 hour)
• Discharge temperature sensor <Thermistor>
• Apply Heat Pump Model Only.
– 10 –
Remote Control
Operation ON/OFF
Operation Mode Selection
• Cooling, Soft Dry, Auto, Fan 
¤I
Cooling Only Model
• Cooling, Heating, Soft Dry, Fan, 
¤I
E/heater  Heat Pump Model
Fan Speed Selection
Setting the temperature
Timer Control
Airflow Direction Control
• High, Medium, Low
• High, Medium
• Up or Down
• Off Timer(1, 2, 3...7 hour)
• Airflow direction Auto-Swing and Manual control
¡
LP-F80
****
Models have not Remote controller.
Page of 127