DOWNLOAD LG LB-D2460HL Service Manual ↓ Size: 805.53 KB | Pages: 40 in PDF or view online for FREE

Model
LB-D2460HL
Pages
40
Size
805.53 KB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner
File
lb-d2460hl.pdf
Date

LG LB-D2460HL Service Manual ▷ View online

Product Specifications (Cooling & Heating) 
Air Circulation
m
3
/min
Dimensions
(W
¡¿
H
¡¿
D)
Net. Weight
mm
kg
W
A
LB-D2460HL
–5–
Service Valve & 
Connecting Tube
Model Name
Item
Unit
Cooling Capacity
Btu/h(W)
Heating Capacity
Btu/h(W)
Moisture Removal
§⁄
/h
Power Source
§j
, V, Hz
Indoor
Outdoor
Input
Cooling
Heating
Running Current
Cooling
Heating
E.E.R.
Btu/h-W
Indoor
Outdoor
Indoor
Outdoor
Refrigerant (R-22)
g
Remocon Type
Liquid
Gas
Drain Hose
Connecting Wire
Main Power Cable
Time Delay Safety Function
Soft Dry
Fan Speed (Indoor)
Timer
Self-Diagnosis
24,000(7,033)
24,000(7,033)
3.5
,
220-240V, 50Hz
20
49
3,100
3,050
15
15
8.6
880 x 281 x 575
870 x 655 x 320
42
62
1,860
L.C.D
3/8" (9.52)
5/8" (15.88)
O
0.75mm
2
¤C
3.5mm
2
¤C
O
O
3 (Hi, Med, Low)
24Hrs
O
Dimensions
MODEL:LB-D2460HL
Indoor Unit 
870
655
320
880
575
281
–6–
Outdoor Unit 
Refrigeration Cycle Diagram
• MODEL: LB-D2460HL
(
■ 
Rated performance for refrigerant line length of: 7.5m)
For installation over rated distance, 60g of refrigerant should be added for each meter.
ex) When installed at a distance of 15m, 450g of refrigerant should be added.
(15-7.5) x 60g = 450g
Pipe size(Diameter: ø)
Piping length(m)
Elevation(m)
MODEL
Gas
Liquid
Rated
Max.
Rated
Max.
LB-D2460HL
5/8"
3/8"
5
25
5
8
60
INDOOR UNIT
OUTDOOR UNIT
HEAT
EXCHANGER
HEAT
EXCHANGER
COMPRESSOR
GAS SIDE
LIQUID SIDE
COOLING
HEATING
REVERSING
VALVE
CHECK VALVE
CAPILLARY TUBE
–7–
Additional
refrigerant
(g/m)
Wiring Diagram
MODEL: LB-D2460HL
• Indoor Unit
• Outdoor Unit
–8–
P/No: 3854A90008T
Page of 40
Display